Ambu AuraOnce versus i-gel laryngeal mask airway in infants and children undergoing surgical procedures A randomized controlled trial

被引:9
|
作者
Alzahem, Abdulrahman M. [1 ]
Aqil, Mansoor [2 ]
Alzahrani, Tariq A. [2 ]
Aljazaeri, Ayman H. [1 ]
机构
[1] King Saud Univ, Coll Med, King Saud Univ Med City, Dept Pediat Surg, Riyadh, Saudi Arabia
[2] King Saud Univ, Coll Med, King Saud Univ Med City, Dept Anesthesiol, Riyadh, Saudi Arabia
关键词
SUPRAGLOTTIC AIRWAY; ANESTHETIZED PATIENTS; INTRAOCULAR-PRESSURE; VENTILATED CHILDREN; PEDIATRIC-PATIENTS; COHORT EVALUATION; SCORING SYSTEM; INSERTION; LMA-CLASSIC(TM); PERFORMANCE;
D O I
10.15537/smj.2017.5.17960
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare the efficacy and performance of the pediatric Ambu AuraOnce (Ambu AO) mask (Ambu, Copenhagen, Denmark) and i-gel mask (Intersurgical Ltd., Wokingham, United Kingdom). Methods: From May 2015 to September 2016, 112 patients, 0-14 years old, underwent elective surgery at a tertiary university hospital (Riyadh, Saudi Arabia). They were randomly assigned to the Ambu AO or i-gel group. Three groups underwent a subgroup analysis: <= 5 kg (group 1), 5.1-10.0 kg (group 2), and >10 kg (group 3). Results: The oropharyngeal leak pressure was significantly higher for the i-gel (25.4 +/- 4.1 cm H2O) than for the Ambu AO (22.5 +/- 3.9 cm H2O, p<0.001). The Ambu AO had a slightly higher ease of insertion compared to the i-gel (100% versus 94%, p=0.08) and required less manipulation (2% versus 11%, p=0.07). The Ambu AO and i-gel showed non-significant differences in performance between weight groups. There were statistically significant differences for higher leak pressure in group 2 (p=0.01) and group 3 (p=0.002) in favor of the i-gel, and for less manipulation in the Ambu AO in group 1 (p=0.04). Fiberoptic viewing was superior in group 2 for the i-gel (p=0.03) and in group 3 for the Ambu AO (p=0.02). Conclusion: Both devices demonstrated equally good performance with low morbidity. The Ambu AO had a statistical tendency towards easier insertion and less manipulation. Confirming this finding will require large scale trials.
引用
收藏
页码:482 / 490
页数:9
相关论文
共 50 条
  • [21] A Randomized Controlled Trial Comparing Ambu AuraGain and i-gel in Young Pediatric Patients
    Kim, Ha-Jung
    Park, Hee-Sun
    Kim, Soo-Young
    Ro, Young-Jin
    Yang, Hong-Seuk
    Koh, Won Uk
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (08)
  • [22] Spatial relationship of i-gel® and Ambu® AuraOnce™ on pediatric airway: a randomized comparison based on three dimensional magnetic resonance imaging
    Aqil, Mansoor
    Delvi, Bilal
    Abujamea, Abdullah
    Alzahrani, Tariq
    Alzahem, Abdulrahman
    Mansoor, Saara
    Aljazaeri, Ayman
    MINERVA ANESTESIOLOGICA, 2017, 83 (01) : 23 - 32
  • [23] A randomised crossover trial comparing the i-gel supraglottic airway and classic laryngeal mask airway
    Janakiraman, C.
    Chethan, D. B.
    Wilkes, A. R.
    Stacey, M. R.
    Goodwin, N.
    ANAESTHESIA, 2009, 64 (06) : 674 - 678
  • [24] Comparison of Ambu AuraGain and BlockBuster laryngeal mask for controlled ventilation in children undergoing minor surgical procedures under general anesthesia: A prospective randomized controlled study
    Kumar, Kanil Ranjith
    Soni, Lipika
    Sinha, Renu
    Muthiah, Thilaka
    Patel, Nishant
    Shende, Dilip K.
    Subramaniam, Rajeshwari
    PEDIATRIC ANESTHESIA, 2023, 33 (06) : 474 - 480
  • [25] Use of the i-gel® laryngeal mask for management of a difficult airway
    Emmerich, M.
    Dummler, R.
    ANAESTHESIST, 2008, 57 (08): : 779 - 781
  • [26] Comparative evaluation of Intubating Laryngeal Mask Airway (ILMA), I-gel and Ambu AuraGain for blind tracheal intubation in adults
    Sarma, Riniki
    Kumar, Rakesh
    Kumar, Neera Gupta
    Agarwal, Munisha
    Bhardwaj, Manoj
    Ansari, Saud Ahmed
    Deepak, G. P.
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2022, 38 (01) : 130 - 136
  • [27] Evaluation der neuen Kehlkopfmasken Ambu AuraOnce™ und Intersurgical i-gel™Platzierbarkeit, Dichtigkeit, Patientenkomfort und AtemwegsmorbiditätEvaluation of the new supraglottic airway devices Ambu AuraOnce™ and Intersurgical i-gel™Positioning, sealing, patient comfort and airway morbidity
    J.F. Heuer
    M. Stiller
    J. Rathgeber
    C. Eich
    K. Züchner
    M. Bauer
    A. Timmermann
    Der Anaesthesist, 2009, 58 (8) : 813 - 820
  • [28] Safety and efficacy of laryngeal mask airway Supreme versus laryngeal mask airway ProSeal: a randomized controlled trial
    Seet, Edwin
    Rajeev, Subramanyam
    Firoz, Tamal
    Yousaf, Farhanah
    Wong, Jean
    Wong, David T.
    Chung, Frances
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) : 602 - 607
  • [29] The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients
    Shin, Won-Jung
    Cheong, Yu-Seon
    Yang, Hong-Seuk
    Nishiyama, Tomoki
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) : 598 - 601
  • [30] Observation of ventilation effects of I-gel™, Supreme™ and Ambu AuraOnce™ with respiratory dynamics monitoring in small children
    Gu, Zhiqing
    Jin, Quanying
    Liu, Junjun
    Chen, Lianhua
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) : 1035 - 1041