Comparison of the i-gel™ with the AuraGain™ laryngeal mask airways in patients with a simulated cervical immobilization: a randomized controlled trial

被引:3
|
作者
Hur, Min [1 ,2 ]
Choi, Seungeun [2 ,3 ]
Row, Hyung S. [2 ,3 ]
Kim, Tae K. [2 ,3 ]
机构
[1] Ajou Univ, Sch Med, Dept Anesthesiol & Pain Med, Suwon, South Korea
[2] Seoul Natl Univ Hosp, Dept Anesthesiol & Pain Med, Seoul, South Korea
[3] Seoul Natl Univ, Dept Anesthesiol & Pain Med, SMG SNU Boramae Med Ctr, Coll Med, Seoul, South Korea
关键词
Laryngeal masks; Anesthesia; general; Airway management; SUPRAGLOTTIC AIRWAY; I-GEL; DIFFICULT AIRWAY; TRACHEAL INTUBATION; AMBU AURAGAIN; LMA-SUPREME; DEVICES; PRESSURE; CUFF; CLASSIFICATION;
D O I
10.23736/S0375-9393.20.14237-8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: The use of second generation supraglottic airway devices is recommended for airway rescue in failed tracheal intubation. This study was performed to compare the clinical performance of the i-gel (TM) with that of the AuraGain (TM) in patients with simulated cervical immobilization. METHODS: We conducted a prospective, randomized controlled trial in 104 patients undergoing general anesthesia from June to September 2018 at the Seoul National University Hospital. Patients were randomly allocated to receive either the i-gel (TM) or the AuraGain (TM) device. A difficult airway was simulated using a cervical collar limiting the mouth opening and neck movement. The primary outcome was the initial oropharyngeal leak pressure. RESULTS: The rate of successful insertion at the first attempt was 92.3% for the i-gel (TM) and 86% for the AuraGain (TM). There were no significant differences in the initial and 5-min ompharyngeal leak pressures between the i-gel (TM) and the AuraGain (TM) (21 +/- 4 vs. 22 +/- 5 cmH(2)O, P=0.229; and 22 +/- 5 vs. 23 +/- 5 cmH(2)O, P=0.308, respectively). The time to successful device insertion was shorter (20 [16-23] vs. 25 [20-41]s. P<0.001) and device insertion was easier (P<0.001) in the i-gel (TM) group than in the AuraGain (TM) group. The blood staining of the device was more frequently observed in the AuraGain (TM) (3 [5.8%] vs. 12 [23.5%] patients, P=0.003). CONCLUSIONS: The i-gel (TM) and the AuraGain (TM) showed comparable orophamyngeal leak pressures and success rates in the first attempt in patients with simulated cervical immobilization. However, the i-gel (TM) was easier to insert and required less time for insertion than the AuraGain (TM).
引用
收藏
页码:727 / 735
页数:9
相关论文
共 50 条
  • [1] A RANDOMIZED COMPARISON OF I-GEL AND AMBU AURAGAIN TM LARYNGEAL MASK AIRWAY IN PATIENTS WITH SIMULATED CERVICAL IMMOBILIZATION
    Hur, Min
    Kim, Tae Kyong
    Lee, Hyung-Chul
    [J]. ANESTHESIA AND ANALGESIA, 2019, 128 : 17 - 20
  • [2] The comparison of ProSeal and I-gel laryngeal mask airways in anesthetized adult patients under controlled ventilation
    Ekinci, Osman
    Abitagaoglu, Suheyla
    Turan, Guldem
    Sivrikaya, Zubeyir
    Bosna, Gulsen
    Ozgultekin, Asu
    [J]. SAUDI MEDICAL JOURNAL, 2015, 36 (04) : 432 - 436
  • [3] A Randomized Controlled Trial Comparing Ambu AuraGain and i-gel in Young Pediatric Patients
    Kim, Ha-Jung
    Park, Hee-Sun
    Kim, Soo-Young
    Ro, Young-Jin
    Yang, Hong-Seuk
    Koh, Won Uk
    [J]. JOURNAL OF CLINICAL MEDICINE, 2019, 8 (08)
  • [4] A RANDOMIZED COMPARISON OF THE I-GEL WITH THE PROSEAL LARYNGEAL MASK AIRWAY IN PEDIATRIC PATIENTS
    Fukuhara, A.
    Okutani, R.
    Oda, Y.
    [J]. ANESTHESIA AND ANALGESIA, 2012, 114
  • [5] Comparison of Laryngeal Mask Supreme™ and i-gel™ in simulated difficult airway in anesthetized patients
    Theiler, L.
    Kleine-Brueggeney, M.
    Urwyler, N.
    Luyet, C.
    Kaiser, D.
    Greif, R.
    [J]. SWISS MEDICAL WEEKLY, 2008, 138 (41-42) : 7S - 7S
  • [6] Comparison of the laryngeal mask airway supreme and the i-gel in paralysed elderly patients A randomised controlled trial
    Kim, Myoung H.
    Lee, Jae H.
    Choi, Yong S.
    Park, Sujung
    Shin, Seokyung
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2018, 35 (08) : 598 - 604
  • [7] A RANDOMIZED CONTROLLED TRIAL COMPARING THE CLINICAL PERFORMANCE OF AMBU AURAGAIN AND I-GEL IN YOUNG PEDIATRIC PATIENTS
    Koh, Wonuk
    Kim, Ha-Jung
    Park, Hee-Sun
    Ro, Young Jin
    Yang, Hong-Seuk
    [J]. ANESTHESIA AND ANALGESIA, 2019, 128 : 25 - 27
  • [8] Fiberoptic intubation of severely obese patients through supraglottic airway: A prospective, randomized trial of the Ambu® AuraGain™ laryngeal mask vs the i-gel™ airway
    Moser, Berthold
    Keller, Christian
    Audige, Laurent
    Dave, Mital H.
    Bruppacher, Heinz R.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2019, 63 (02) : 187 - 194
  • [9] Crossover Comparison of the Laryngeal Mask Supreme™ and the i-gel™ in Simulated Difficult Airway Scenario in Anesthetized Patients
    Theiler, Lorenz G.
    Kleine-Brueggeney, Maren
    Kaiser, Dagmar
    Urwyler, Natalie
    Luyet, Cedric
    Vogt, Andreas
    Greif, Robert
    Unibe, M. M. E.
    [J]. ANESTHESIOLOGY, 2009, 111 (01) : 55 - 62
  • [10] A randomized equivalence trial comparing the i-gel and laryngeal mask airway Supreme in children
    Jagannathan, Narasimhan
    Sommers, Katherine
    Sohn, Lisa E.
    Sawardekar, Amod
    Shah, Ravi D.
    Mukherji, Isabella I.
    Miller, Steven
    Voronov, Polina
    Seraphin, Sally
    [J]. PEDIATRIC ANESTHESIA, 2013, 23 (02) : 127 - 133