The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems

被引:0
|
作者
Schulz, G [1 ]
Fischer, J [1 ]
Neff, T [1 ]
Bänziger, O [1 ]
Weiss, M [1 ]
机构
[1] Univ Zurich, Kinderklin, Abt Neonatol, CH-8032 Zurich, Switzerland
来源
ANAESTHESIST | 2000年 / 49卷 / 12期
关键词
syringe pumps; air; infusion line occlusion; drug delivery; complications;
D O I
10.1007/s001010070016
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Application of highly concentrated short-acting vasoactive drugs in the critically ill patient requires precisely working syringe pump systems for continuous intravenous drug delivery. We performed a bench study to investigate the consequences of small amounts of air entrapped within a 50-ml infusion syringe. In particular we studied the effect of entrapped air on drug delivery after moderate vertical displacement of the pump by 50 cm (e. g, in preparation for transport) and the effect on the time required to trigger the pressure alarm after occlusion of the infusion line. At a flow rate of 1 ml/h,lowering the syringe pump prolonged the zero-drug delivery time from (mean+/-SD) 4.1+/-0.8 min (without air) to 6.2+/-0.9 (with 1 mi air) and to 13.1+/-0.9 min (with 2 mi of air, p<0.001 for all comparisons). Entrapping of 2 mi of air within the syringe resulted in a 2.6-fold prolongation of the occlusion alarm time after accidental occlusion of the infusion line and a 3-fold increase of the resulting infusion bolus after occlusion. Enclosed air within infusion syringes considerably affects the syringe compliance. It increases the susceptibility of constant drug delivery to vertical displacement of syringe pumps and impairs the occlusion alarm function. Therefore, any air in syringe of infusion pump systems should be carefully removed. To avoid infusion boluses of short-acting vasoactive drugs after accidental occlusions, the occluded infusion line should be released to ambient pressure first.
引用
收藏
页码:1018 / 1023
页数:6
相关论文
共 50 条
  • [21] SYRINGE INFUSION PUMP VERSUS GRAVITY-FEED MINIBOTTLE - EVALUATION OF SYSTEMS
    BAPTISTA, RJ
    DRISCOLL, DF
    DRUG INTELLIGENCE & CLINICAL PHARMACY, 1988, 22 (12): : 1004 - 1005
  • [22] EFFECT OF SYRINGE-PUMP POSITION ON INFUSION OF FAT EMULSION WITH A PRIMARY SOLUTION
    MORGAN, DE
    BERGDALE, S
    ZIEGLER, EE
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1985, 42 (05): : 1110 - 1111
  • [23] Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting
    Baeckert, Martina
    Batliner, Martin
    Grass, Beate
    Buehler, Philipp K.
    Daners, Marianne Schmid
    Meboldt, Mirko
    Weiss, Markus
    BRITISH JOURNAL OF ANAESTHESIA, 2020, 124 (02) : 173 - 182
  • [24] CHANGES IN FAT CONCENTRATION OF HUMAN-MILK DURING CONSTANT SYRINGE PUMP INFUSION - EFFECTS OF INFUSION RATE, SYRINGE POSITION, AND HOMOGENIZATION
    GREER, FR
    HAUSMANSTOKES, E
    MCCORMICK, A
    CLINICAL RESEARCH, 1983, 31 (04): : A790 - A790
  • [25] PHARMACY-INITIATED IMPLEMENTATION OF A SYRINGE PUMP INFUSION SYSTEM
    GOUDREAU, JB
    MORRISSEY, JM
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1985, 42 (03): : 584 - 587
  • [26] Development of an Application for Remote Syringe Pump Control in Anesthesia Infusion
    Correia, Rui
    Gabriel, Joaquim
    Amorim, Pedro
    Nunes, Catarina S.
    Ferreira, David A.
    PROCEEDINGS OF 2015 3RD EXPERIMENT AT INTERNATIONAL CONFERENCE (EXP AT'15), 2015, : 130 - +
  • [27] Consequences of syringe size sensor malfunction in a modern infusion pump
    Derrick, JL
    Ho, AMH
    Cho, AMW
    ANAESTHESIA AND INTENSIVE CARE, 2003, 31 (01) : 75 - 79
  • [28] Effects of infusion tubing line lengths and syringe sizes on infusion system compliance: an experimental study using a syringe-type infusion pump at low flow rate
    Hong, Kwan Young
    Lee, Eun Kyung
    Kim, Youyoung
    Choi, Dan-Cheong
    Min, Jeong-Jin
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (05) : 1379 - 1386
  • [29] Effects of infusion tubing line lengths and syringe sizes on infusion system compliance: an experimental study using a syringe-type infusion pump at low flow rate
    Kwan Young Hong
    Eun Kyung Lee
    Youyoung Kim
    Dan-Cheong Choi
    Jeong-Jin Min
    Journal of Clinical Monitoring and Computing, 2023, 37 : 1379 - 1386
  • [30] The effects of syringe size on the flow dynamics of syringe infusion pumps
    Brinker, J
    McKinley, R
    Cislo, R
    Yano, C
    CANADIAN MEDICAL AND BIOLOGICAL ENGINEERING SOCIETY, PROCEEDINGS, 1997, : 142 - 143