The influence of cooling rate on the accuracy of normoxic polymer gel dosimeters

被引:48
|
作者
De Deene, Y.
Pittomvils, G.
Visalatchi, S.
机构
[1] State Univ Ghent Hosp, Radiotherapy Dept P7, B-9000 Ghent, Belgium
[2] Shree Krishna Hosp, MS Patel Canc Ctr, Dept Radiat Oncol, Karamsad 388325, Gujarat, India
[3] Med Res Ctr, Karamsad 388325, Gujarat, India
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 10期
关键词
D O I
10.1088/0031-9155/52/10/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polymer gel dosimeters offer a wide range of applications in the three-dimensional verification of complex radiation dose distributions such as in intensity-modulated radiotherapy (IMRT). With the release of polymer gel dosimeters that can be fabricated in normal atmospheric ('normoxic') conditions, the gel manufacturing process has been significantly simplified. Gel dosimeters are calibrated by use of a series of calibration vials irradiated with known doses or by use of a calibration phantom with a known dose distribution. The overall accuracy of the polymer gel dosimeters is determined by different dosimetric properties. In this study, we show the influence of the temperature history during storage of the gel dosimeter on the dose response curve for two gel dosimeters using the monomers acrylamide/N,N'-methylene-bis-acrylamide (nPAG) and methacrylic acid (nMAG) respectively and bis[tetrakis(hydroxymethyl)phosphonium]sulphate (THP) as antioxidant in both gel dosimeters. This study reveals that differences in temperature history after fabrication of normoxic polymer gel dosimeters may compromise the dosimetric accuracy. It was found that the acrylamide based gel dosimeter (nPAG) is less dependent on the post-manufacture temperature history than the methacrylic acid based gel dosimeter (nMAG). The importance of an equal temperature history for the gel dosimeter and calibration vials is emphasized by this study. A reproducibility study has also been performed on the nPAG gel dosimeter when additional efforts are made to control the temperature changes upon cooling.
引用
收藏
页码:2719 / 2728
页数:10
相关论文
共 50 条
  • [31] Polymer Gel Dosimeters for use in Targeted Radionuclide Therapy
    Gear, J. I.
    Flux, G. D.
    Partridge, M.
    Ott, R. J.
    Charles-Edwards, E.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S207 - S207
  • [32] Polymer gel dosimeters with PVA-GA matrix
    Abtahi, Seyed Mohammad Mahdi
    Abandansari, Hamid Sadeghi
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (03) : 651 - 658
  • [33] Measurement of ultrasonic attenuation coefficient in polymer gel dosimeters
    Mather, ML
    Charles, PH
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (20): : N269 - N275
  • [34] Investigating potential physicochemical errors in polymer gel dosimeters
    Sedaghat, Mahbod
    Bujold, Rachel
    Lepage, Martin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (18): : 6083 - 6107
  • [35] Response overshoot: a challenge for the application of polymer gel dosimeters
    Seyed Mohammad Mahdi Abtahi
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2019, 321 : 885 - 893
  • [36] Attenuation of diagnostic energy photons by polymer gel dosimeters
    Trapp, JV
    Michael, G
    de Deene, Y
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (23): : 4247 - 4258
  • [37] Practical role of polymerization inhibitors in polymer gel dosimeters
    Magugliani, G.
    Liosi, G. M.
    Marranconi, M.
    Micotti, E.
    Caprioli, M.
    Gambirasio, A.
    Locatelli, F.
    Macerata, E.
    Mossini, E.
    Salmoiraghi, P.
    Trombetta, L.
    Vavassori, V.
    Forloni, G.
    Mariani, M.
    Bombardieri, E.
    [J]. NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (06):
  • [38] DYNAMIC MODELLING OF THE DOSE RESPONSE OF POLYMER GEL DOSIMETERS
    Ceberg, S.
    Lepage, M.
    Back, S.
    Gustafsson, H.
    Ceberg, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S408 - S409
  • [39] Photon and neutron kerma coefficients for polymer gel dosimeters
    El-Khayatt, A. M.
    Rene Vega-Carrillo, Hector
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 792 : 6 - 10
  • [40] Simulation of Water Equivalency of Polymer Gel Dosimeters with GAMOS
    Ozbay, Turkan
    Yurt, Aysegul
    Ozsoykal, Ismail
    [J]. JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES, 2020, 4 (01): : 51 - 58