Simulation of Water Equivalency of Polymer Gel Dosimeters with GAMOS

被引:0
|
作者
Ozbay, Turkan [1 ,2 ]
Yurt, Aysegul [2 ,3 ]
Ozsoykal, Ismail [2 ]
机构
[1] Izmir Univ Econ, Vocat Sch Hlth Serv, Izmir, Turkey
[2] Dokuz Eylul Univ, Dept Med Phys, Izmir, Turkey
[3] Dokuz Eylul Univ, Vocat Sch Hlth Serv, Izmir, Turkey
来源
关键词
Polymer gel; Dosimeter; Monte Carlo; GAMOS; Simulation; RADIATION-DOSE DISTRIBUTIONS; X-RAY; RADIOLOGICAL PROPERTIES; FRAMEWORK; TOOL; CT;
D O I
10.30621/jbachs.2020.899
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: Polymer gel materials are used as dosimeters to provide three dimensional radiation dose distribution. An ideal gel dosimeter should offer radiological properties equivalent to water. This study aims to determine and compare the water equivalencies of various new polymer gel mixtures using Geant4-based Architecture for Medicine-Oriented Simulations (GAMOS) software program. Methods: To do this, percentage depth dose curves of the simulated polymer gel mixtures were compared with water curves. Different combinations of materials from 2 main classes were used in the mixtures: (1) Sodium Carboxymethyl Cellulose (SODIUM CMC), Polyvinyl Alcohol (PVA) and Polyethylene Glycol (PEG) as gel matrix, (2) 2-Hydroxyethyl Methacrylate (HEMA), 1-Vinyl-2-Pyrrolidinone (VP) and Diethylene Glycol Dimethacrylate (DEGDMA) as monomer. Each mixture also contained ultra-pure water and an antioxidant material called Tetrakis Hydroxymethyl Phosphonium Chloride ( THPC). Results: Percentage depth doses of gel mixtures and water was calculated for 6, 18 MV and 50, 70, 100, 150 kVp X rays. The mixture sample showing radiological behavior nearest to water over all energies was observed to be 31a (Water, PEG, HEMA, THPC), while the largest difference is observed in 11a (Water, SODIUM CMC, HEMA, THPC). Conclusion: As a result, simulated gel formulations were found to be radiologically water equivalent.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [1] Water equivalence of polymer gel dosimeters
    Sellakumar, P.
    Jebaseelan Samuel, E. James
    Supe, Sanjay S.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (07) : 1108 - 1115
  • [2] Water and tissue equivalency of some gel dosimeters for photon energy absorption
    Un, Adem
    [J]. APPLIED RADIATION AND ISOTOPES, 2013, 82 : 258 - 263
  • [3] Investigation of radiological properties and water equivalency of PRESAGE® dosimeters
    Gorjiara, Tina
    Hill, Robin
    Kuncic, Zdenka
    Adamovics, John
    Bosi, Stephen
    Kim, Jung-Ha
    Baldock, Clive
    [J]. MEDICAL PHYSICS, 2011, 38 (04) : 2265 - 2274
  • [4] Investigation of Water Equivalency of PRESAGE Dosimeters for Electron Beam Radiotherapy
    Gorjiara, T.
    Hill, R.
    Kuncic, Z.
    Baldock, C.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [5] Ultrasonic absorption in polymer gel dosimeters
    Mather, ML
    Collings, AF
    Bajenov, N
    Whittaker, AK
    Baldock, C
    [J]. ULTRASONICS, 2003, 41 (07) : 551 - 559
  • [6] Ultrasound evaluation of polymer gel dosimeters
    Mather, ML
    Whittaker, AK
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09): : 1449 - 1458
  • [7] Response modification in polymer gel dosimeters
    Maryanski, M
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1209 - 1209
  • [8] Radiological properties of normoxic polymer gel dosimeters
    Venning, AJ
    Nitschke, KN
    Keall, PJ
    Baldock, C
    [J]. MEDICAL PHYSICS, 2005, 32 (04) : 1047 - 1053
  • [9] Polymer gel dosimeters with PVA–GA matrix
    Seyed Mohammad Mahdi Abtahi
    Hamid Sadeghi Abandansari
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 651 - 658
  • [10] Polymer Gel Dosimeters for use in Targeted Radionuclide Therapy
    Gear, J. I.
    Flux, G. D.
    Partridge, M.
    Ott, R. J.
    Charles-Edwards, E.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S207 - S207