Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves

被引:223
|
作者
Flameng, Willem [1 ]
Herregods, Marie-Christine [2 ]
Vercalsteren, Monique [1 ]
Herijgers, Paul [1 ]
Bogaerts, Kris [3 ]
Meuris, Bart [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, Div Cardiac Surg, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Dis, Dept Cardiol, Leuven, Belgium
[3] Univ Hasselt, Ctr Biostat, Diepenbeek, Belgium
关键词
bioprosthesis; prosthesis-patient mismatch; surgery; valves; LONG-TERM SURVIVAL; AORTIC-VALVE; REPLACEMENT; POSITION; STENTLESS; IMPACT; DETERIORATION; RISK; CALCIFICATION; REOPERATION;
D O I
10.1161/CIRCULATIONAHA.109.901272
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Prosthesis-patient mismatch (P-PtM) after aortic valve replacement results in disturbed valve performance associated with increased pressure gradients. However, it is unknown whether this can be related to future structural valve deterioration (SVD) of the bioprosthesis. Methods and Results-In 564 patients (mean age, 74+/-5 years) receiving an aortic valve bioprosthesis, clinical follow-up (median, 6.1 years; maximum, 16.4 years) was analyzed including echocardiography. SVD was diagnosed in 40 patients (7%) as substantially increased stenosis (n=24) or regurgitation (n=16) of the operated valve over time. When patients with P-PtM (effective orifice area index <0.85 cm(2)/m(2); n=285) developed SVD, it was preferentially of the stenosis type, whereas when patients without P-PtM (n=279) developed SVD, the majority was of the incompetence type (P<0.05). Multivariable analysis including patient-and valve-related variables revealed that P-PtM and label size <= 21 were independent predictors of SVD (P=0.04 and P=0.02, respectively). A nonparametric Turnbull estimate analysis showed that SVD is virtually nonexistent for up to 9 years in patients without P-PtM. Thereafter, SVD starts to occur and is mainly of the incompetence-type SVD (79% of cases). In patients with P-PtM, SVD starts to occur after 2 to 3 years after implantation and is mainly of the stenosis-type SVD (81% of cases). Conclusions-These data suggest that stenosis-type SVD is an early, P-PtM-related, and thus preventable phenomenon. Incompetence-type SVD is a time-dependent, nonspecific wear damage to bioprosthetic valves, which is not related to P-PtM. (Circulation. 2010; 121: 2123-2129.)
引用
收藏
页码:2123 / 2129
页数:7
相关论文
共 50 条
  • [41] Impact of prosthesis-patient mismatch on year mortality after valve replacement
    Olivencia, Lorena
    Fernandez, Maria Dolores
    Macias, Ines
    Bono, Javier Munoz
    Alvarez, Miguel
    Gutierrez, Raquel
    Trujillo, Elena
    Rivera, Ricardo
    CRITICAL CARE MEDICINE, 2013, 41 (12)
  • [42] REPLY: Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement
    Okuno, Taishi
    Lanz, Jonas
    Heg, Dik
    Pilgrim, Thomas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (01) : 139 - 139
  • [43] Prosthesis-patient mismatch after mitral valve replacement: Back to reality
    Pibarot, Philippe
    Magne, Julien
    Dumesnil, Jean G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (02): : 464 - 465
  • [44] Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch
    Kim, Hyo-Hyun
    Lee, Sak
    Joo, Hyun-Chel
    Kim, Jung-Hwan
    Youn, Young-Nam
    Yoo, Kyung-Jong
    Lee, Seung-Hyun
    ANNALS OF THORACIC SURGERY, 2020, 109 (03): : 661 - 667
  • [45] Prosthesis-patient mismatch following aortic and mitral valves replacement - A comprehensive review
    Joury, Abdulaziz
    Duran, Antonio
    Stewart, Merrill
    Gilliland, Yvonne E.
    Spindel, Stephen M.
    Qamruddin, Salima
    PROGRESS IN CARDIOVASCULAR DISEASES, 2022, 72 : 84 - 92
  • [46] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Sa, Michel Pompeu
    Jacquemyn, Xander
    Van den Eynde, Jef
    Tasoudis, Panagiotis
    Dokollari, Aleksander
    Torregrossa, Gianluca
    Sicouri, Serge
    Clavel, Marie-Annick
    Pibarot, Philippe
    Ramlawi, Basel
    JACC-CARDIOVASCULAR IMAGING, 2022, 16 (03) : 298 - 310
  • [47] Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Dayan, Victor
    Vignolo, Gustavo
    Soca, Gerardo
    Paganini, Juan Jose
    Brusich, Daniel
    Pibarot, Philippe
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) : 924 - 933
  • [48] Impact of prosthesis-patient mismatch on survival after mitral valve replacement
    Magne, J.
    Mathieu, P.
    Dumesnil, J. G.
    Tanne, D.
    Dagenais, F.
    Doyle, D.
    Pibarot, P.
    EUROPEAN HEART JOURNAL, 2006, 27 : 833 - 833
  • [49] Prosthesis-patient mismatch affects survival after aortic valve replacement
    Rao, V
    Jamieson, WRE
    Ivanov, J
    Armstrong, S
    David, TE
    CIRCULATION, 2000, 102 (19) : 5 - 9
  • [50] eComment: Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences
    Poullis, Michael
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 13 (06) : 610 - 610