Prosthesis-patient mismatch affects survival after aortic valve replacement

被引:1
|
作者
Rao, V
Jamieson, WRE
Ivanov, J
Armstrong, S
David, TE
机构
[1] Toronto Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
[2] Vancouver Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
关键词
aorta; valves; survival;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Surgeons traditionally avoid the use of "small" aortic prostheses because of the potential for residual left ventricular outflow tract obstruction and persistent transvalvular gradients. This study examines the ratio between prosthetic valve size and the body surface area (BSA) of patients undergoing aortic valve replacement (AVR). We sought to determine the effect of potential "prosthesis-patient" mismatch on long-term survival. Methods and Results-Follow-up was conducted on 2981 patients who underwent AVR with stented bioprostheses between 1976 and 1996. To account for differences between manufacturers' labeled valve sizes, we calculated the ratio between the prosthetic valve effective orifice area (EOA) and the patient's BSA (recorded for 2154 patients). The lowest decile in this cohort had a calculated EOA/BSA of <0.75 cm(2)/m(2) (Small group, n=227) compared with the control group (n=1927), in whom the EOA/BSA ratio was >0.75 cm(2)/m(2). Operative mortality was higher in the Small group (8% versus 5%, P=0.03), Actuarial survival at 12 years was 50+/-5% in the Small group compared with 49+/-2% in the control group (P=0.27). However, freedom from valve-related mortality was significantly lower in the Small group (75+/-5% versus 84+/-2%, P=0.004). Cox regression analysis determined age and NYHA functional class to be the multivariate predictors of overall mortality, whereas advanced age and EOA/BSA <0.75 cm(2)/m(2) were found to be the predictors of valve-related mortality. Conclusions-Prosthesis-patient mismatch results in significantly higher early and late mortality after bioprosthetic AVR. We recommend careful selection of stented bioprostheses to ensure an adequate ratio of EOA to BSA. An EOA/BSA ratio of >0.75 cm(2)/m(2) may avoid residual left ventricular outflow tract obstruction and persistent transvalvular gradients. Careful prosthesis-patient matching will improve both early and late survival after AVR.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 50 条
  • [1] Prosthesis-patient Mismatch Affects Long-term Survival After Aortic Valve Replacement
    Ennker, Juergen
    Albert, Alexander
    Boening, Andreas
    Ennker, Ina C.
    Florath, Ines
    CIRCULATION, 2010, 122 (21)
  • [2] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [3] Prosthesis-patient mismatch affects long-term survival after mechanical aortic valve replacement
    Mohan, S
    Kohsaka, S
    Contreras, A
    Lee, VV
    Reul, RM
    Reul, GJ
    Coulter, SA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 282A - 282A
  • [4] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [5] The relevance of prosthesis-patient mismatch after aortic valve replacement
    Pibarot, Philippe
    Dumesnil, Jean G.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 764 - 765
  • [6] Patient-prosthesis mismatch affects survival after aortic valve replacement
    Rao, V
    Jamieson, WRE
    Ivanov, J
    Armstrong, S
    David, TE
    CIRCULATION, 1999, 100 (18) : 461 - 461
  • [8] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Sa, Michel Pompeu
    Jacquemyn, Xander
    Van den Eynde, Jef
    Tasoudis, Panagiotis
    Dokollari, Aleksander
    Torregrossa, Gianluca
    Sicouri, Serge
    Clavel, Marie-Annick
    Pibarot, Philippe
    Ramlawi, Basel
    JACC-CARDIOVASCULAR IMAGING, 2022, 16 (03) : 298 - 310
  • [9] Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Dayan, Victor
    Vignolo, Gustavo
    Soca, Gerardo
    Paganini, Juan Jose
    Brusich, Daniel
    Pibarot, Philippe
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) : 924 - 933
  • [10] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Levesque, Thomas
    Eltchaninoff, Helene
    Chabannes, Romain
    Barbe, Thomas
    Dosseh, Olivier
    Tron, Christophe
    Bettinger, Nicolas
    Bouhzam, Najime
    Hemery, Thibaut
    le Pessec, Guillaume
    Fauvel, Charles
    Cribier, Alain
    Pibarot, Philippe
    Durand, Eric
    CANADIAN JOURNAL OF CARDIOLOGY, 2024, 40 (01) : 113 - 122