Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves

被引:223
|
作者
Flameng, Willem [1 ]
Herregods, Marie-Christine [2 ]
Vercalsteren, Monique [1 ]
Herijgers, Paul [1 ]
Bogaerts, Kris [3 ]
Meuris, Bart [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, Div Cardiac Surg, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Dis, Dept Cardiol, Leuven, Belgium
[3] Univ Hasselt, Ctr Biostat, Diepenbeek, Belgium
关键词
bioprosthesis; prosthesis-patient mismatch; surgery; valves; LONG-TERM SURVIVAL; AORTIC-VALVE; REPLACEMENT; POSITION; STENTLESS; IMPACT; DETERIORATION; RISK; CALCIFICATION; REOPERATION;
D O I
10.1161/CIRCULATIONAHA.109.901272
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Prosthesis-patient mismatch (P-PtM) after aortic valve replacement results in disturbed valve performance associated with increased pressure gradients. However, it is unknown whether this can be related to future structural valve deterioration (SVD) of the bioprosthesis. Methods and Results-In 564 patients (mean age, 74+/-5 years) receiving an aortic valve bioprosthesis, clinical follow-up (median, 6.1 years; maximum, 16.4 years) was analyzed including echocardiography. SVD was diagnosed in 40 patients (7%) as substantially increased stenosis (n=24) or regurgitation (n=16) of the operated valve over time. When patients with P-PtM (effective orifice area index <0.85 cm(2)/m(2); n=285) developed SVD, it was preferentially of the stenosis type, whereas when patients without P-PtM (n=279) developed SVD, the majority was of the incompetence type (P<0.05). Multivariable analysis including patient-and valve-related variables revealed that P-PtM and label size <= 21 were independent predictors of SVD (P=0.04 and P=0.02, respectively). A nonparametric Turnbull estimate analysis showed that SVD is virtually nonexistent for up to 9 years in patients without P-PtM. Thereafter, SVD starts to occur and is mainly of the incompetence-type SVD (79% of cases). In patients with P-PtM, SVD starts to occur after 2 to 3 years after implantation and is mainly of the stenosis-type SVD (81% of cases). Conclusions-These data suggest that stenosis-type SVD is an early, P-PtM-related, and thus preventable phenomenon. Incompetence-type SVD is a time-dependent, nonspecific wear damage to bioprosthetic valves, which is not related to P-PtM. (Circulation. 2010; 121: 2123-2129.)
引用
收藏
页码:2123 / 2129
页数:7
相关论文
共 50 条
  • [31] Prosthesis-patient mismatch: An update
    Dumesnil J.G.
    Pibarot P.
    Current Cardiology Reports, 2011, 13 (3) : 250 - 257
  • [32] Prosthesis-Patient Mismatch in the Elderly
    Gasparovic, Hrvoje
    ANNALS OF THORACIC SURGERY, 2009, 88 (02): : 709 - 710
  • [33] Incidence of Prosthesis-Patient Mismatch in Valve-in-Valve with a Supra-Annular Valve
    Alwan, Louhai
    Ruge, Hendrik
    Krane, Markus
    Prinzing, Anatol
    Noebauer, Christian
    Lange, Rudiger
    Erlebach, Magdalena
    THORACIC AND CARDIOVASCULAR SURGEON, 2023, 71 (08): : 632 - 640
  • [34] Editorial: Prosthesis-patient mismatch prediction in TAVR valve-in-valve procedures
    Bacigalupi, Elena
    MatteoPerfetti
    Zimarino, Marco
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2025, 70 : 48 - 49
  • [35] Device Positioning Predicts Prosthesis-patient Mismatch after Corevalve Implantation
    Jilaihawi, Hasan A.
    Chin, Derek
    Spyt, Tomasz
    Logtens, Elaine
    Jeilan, Mohamed
    Vasa-Nicotera, Mariuca
    Mohammed, Noor
    Bence, Johan
    Kovac, Jan
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 48D - 49D
  • [36] Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?
    Seung Hyun Lee
    Byung Chul Chang
    Young-Nam Youn
    Hyun Chel Joo
    Kyung-Jong Yoo
    Sak Lee
    Journal of Cardiothoracic Surgery, 12
  • [37] Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?
    Lee, Seung Hyun
    Chang, Byung Chul
    Youn, Young-Nam
    Joo, Hyun Chel
    Yoo, Kyung-Jong
    Lee, Sak
    JOURNAL OF CARDIOTHORACIC SURGERY, 2017, 12
  • [38] Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease
    van Slooten, Ymkje J.
    van Melle, Joost P.
    Freling, Hendrik G.
    Bouma, Berto J.
    van Dijk, Arie P. J.
    Jongbloed, Monique R. M.
    Post, Martijn C.
    Sieswerda, Gertjan T.
    in 't Veld, Anna Huis
    Ebels, Tjark
    Voors, Adriaan A.
    Pieper, Petronella G.
    HEART, 2016, 102 (02) : 107 - 113
  • [39] Prosthesis size and prosthesis-patient size are unrelated to prosthesis-patient mismatch - Reply to the editor
    Blackstone, EH
    Gillinov, AM
    Cosgrove, DM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (06): : 1852 - 1854
  • [40] Clinical study of prosthesis-patient mismatch after aortic valve replacement
    武忠