Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?

被引:10
|
作者
Lee, Seung Hyun [1 ]
Chang, Byung Chul [1 ]
Youn, Young-Nam [1 ]
Joo, Hyun Chel [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Sak [1 ]
机构
[1] Yonsei Univ, Coll Med, Yonsei Cardiovasc Res Inst, Severance Cardiovasc Hosp,Div Thorac & Cardiovasc, 250 Seongsanno, Seoul 03722, South Korea
来源
关键词
Heart valve prosthesis; Hemodynamics; Mitral valve; Mortality; Surgery; Valves; SURVIVAL; REGURGITATION; OUTCOMES;
D O I
10.1186/s13019-017-0653-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Prosthesis-patient mismatch (PPM) is characterised by the effects of inadequate prosthesis size relative to body surface area (BSA). The purpose of this study was to determine the impact of PPM on late clinical outcomes after mitral valve replacement (MVR) in rheumatic population. Methods: From 2000 to 2013, a total of 445 patients (mean age 54.2 +/- 11.7 years) underwent isolated MVR (+/- tricuspid annuloplasty) for rheumatic disease were investigated. Effective orifice area (EOA) was determined by the continuity equation and PPM was defined as indexed EOA (EOA/BSA) <= 1.2 cm(2)/m(2). Clinical and echocardiographic follow-up (mean follow up 8.7 +/- 4.0 years) results were compared. Results: 37% of patients (n = 165) had PPM. There were no significant differences in baseline and operative characteristics between patients with and without PPM except age and IEOA. A significant decrease in mean trans-valvular pressure gradient (MPG) over time following MVR, however the change of MPG showed no differences between groups (No PPM vs. PPM: 8.9 +/- 4.7 mmHg -> 3.6 +/- 1.2 mmHg vs. 8.7 +/- 4.5 mmHg. 3.8 +/- 1.4 mmHg, p-value = 0.28). In all patients, there was a reduction of left atrium dimension (58.6 +/- 12.0 mm. 53.2 +/- 12.0 mm vs. 57.9 +/- 8.9 mm -> 52.2 +/- 8.9 mm, p-value = 0.68) and left ventricular end diastolic diameter (49.9 +/- 5.7 mm -> 48.9 +/- 5.7 mm vs. 49.7 +/- 6.0 mm -> 48.3 +/- 5.0 mm, p = 0.24) without statistical significance. Freedom from TR progression rates at 3 and 5 years (99% vs. 98%, 99% vs. 98%, p-value = 0.1), and overall survival rates at 3 and 5 years (97% vs. 96%, 94% vs. 94%, p-value = 0.7) were similar. Conclusion: This study shows that mitral PPM is not associated with atrial/ventricular remodeling and might not influence late clinical outcome including late TR progression, survival in rheumatic population.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?
    Seung Hyun Lee
    Byung Chul Chang
    Young-Nam Youn
    Hyun Chel Joo
    Kyung-Jong Yoo
    Sak Lee
    Journal of Cardiothoracic Surgery, 12
  • [2] Impact of Prosthesis-Patient Mismatch after Mitral Valve Replacement in Rheumatic Population
    Lee, Seung Hyun
    Youn, Young-Nam
    Yoo, Kyung-Jong
    Chang, Byung Chul
    Lee, Sak
    CARDIOLOGY, 2016, 134 (02) : 226 - 226
  • [3] Impact of prosthesis-patient mismatch on survival after mitral valve replacement
    Magne, J.
    Mathieu, P.
    Dumesnil, J. G.
    Tanne, D.
    Dagenais, F.
    Doyle, D.
    Pibarot, P.
    EUROPEAN HEART JOURNAL, 2006, 27 : 833 - 833
  • [4] Impact of prosthesis-patient mismatch on survival after mitral valve replacement
    Magne, Julien
    Mathieu, Patrick
    Dumesnil, Jean G.
    Tanne, David
    Dagenais, Francois
    Doyle, Daniel
    Pibarot, Philippe
    CIRCULATION, 2007, 115 (11) : 1417 - 1425
  • [5] Impact of prosthesis-patient mismatch on mitral regurgitation after aortic valve replacement
    Unger, P.
    Magne, J.
    Eynden, F. Vanden
    Plein, D.
    Van Camp, G.
    Pasquet, A.
    Cosyns, B.
    Dedobbeleer, C.
    Lancellotti, P.
    HEART, 2010, 96 (20) : 1627 - 1632
  • [6] Prosthesis-patient mismatch after mitral valve replacement: Back to reality
    Pibarot, Philippe
    Magne, Julien
    Dumesnil, Jean G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (02): : 464 - 465
  • [7] Impact of prosthesis-patient mismatch on survival after mitral valve replacement: a systematic review
    Zhang Jian-feng
    Wu Yi-cheng
    Shen Wei-feng
    Kong Ye
    CHINESE MEDICAL JOURNAL, 2013, 126 (19) : 3762 - 3766
  • [8] Impact of Prosthesis-Patient Mismatch After Mitral Valve Replacement: A Propensity Score Analysis
    Tsubota, Hideki
    Sakaguchi, Genichi
    Arakaki, Ryoko
    Marui, Akira
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2021, 33 (02) : 347 - 353
  • [9] Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement
    Li, MZ
    Dumesnil, JG
    Mathieu, P
    Pibarot, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (07) : 1034 - 1040
  • [10] Impact of prosthesis-patient mismatch on late outcomes after bioprosthetic mitral valve replacement for mitral regurgitation
    Kitada, Yuichiro
    Arakawa, Mamoru
    Okamura, Homare
    Akiyoshi, Kei
    Hori, Daijiro
    Kimura, Naoyuki
    Yamaguchi, Atsushi
    JOURNAL OF ARTIFICIAL ORGANS, 2022, 25 (02) : 132 - 139