Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope

被引:2
|
作者
Montes, Shivany Y. Condor [1 ]
Bennett, Daniel [1 ]
Bensinger, Ethan [2 ,3 ]
Rani, Lakshmisahithi [1 ]
Sherkat, Younes [4 ]
Zhao, Chao [1 ]
Helft, Zachary [5 ]
Roorda, Austin [2 ,3 ]
Green, Ari J. [1 ,6 ]
Sheehy, Christy K. [1 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Neurol, San Francisco, CA USA
[2] Univ Calif Berkeley, Vis Sci Grad Grp, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[4] Univ Calif Berkeley, Coll Engn, Berkeley, CA 94720 USA
[5] C Light Technol Inc, Berkeley, CA USA
[6] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
来源
基金
美国国家卫生研究院;
关键词
fixational eye motion; microsaccades; retinal eye-tracking; OCULAR DRIFT; MICROSACCADES; SACCADES; VISION;
D O I
10.1167/tvst.11.2.35
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to characterize the benign biological variance of fixational microsaccades in a control population using a tracking scanning laser ophthalmoscope (TSLO), accounting for machine accuracy and precision, to determine ideal testing conditions to detect pathologic change in fixational eye motion (FEM). Methods: We quantified the accuracy and precision of the TSLO, analyzing measurements made by three operators on a model eye. Repeated, 10-second retinal motion traces were then recorded in 17 controls, 3 times a day (morning, afternoon, and evening), on 3 separate days. Microsaccade metrics (MMs) of frequency, average amplitude, peak velocity, and peak acceleration were extracted. Trace to trace, interday, and intraday variability were calculated across all subjects. Results: Intra-operator and machine variation contributed minimally to total variation, with only 0.007% and 0.14% contribution for frequency and amplitude respectively. Bias was detected, with lower accuracy for higher amplitudes. Participants had an average (SD) microsaccade frequency of 0.84 Hz (0.52 Hz), amplitude of 0.32 degrees (0.11 degrees), peak velocity of 43.68 degrees/s (14.02 degrees/s), and peak acceleration of 13,920.04 degrees/s2 (4,186.84 degrees/s2). The first trace recorded within a session significantly differed from the second two in both microsaccade acceleration and velocity (P < 0.05), and frequency was 0.098 Hz higher in the evenings (P < 0.05). There was no MM difference between days and no evidence of a session-level learning effect (P > 0.05). Conclusions: The TSLO is both accurate and precise. However, biological inter- and intra-individual variance is present. Trace to trace variability and time of day should be accounted for to optimize detection of pathologic change.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Comparing fixational stability of Di baseball players as measured by Tracking Scanning Laser Ophthalmoscopy to healthy controls
    Van Meter, Eric
    Tran, Judy
    Green, Zachary
    Sheehy, Christy
    Theis, Jacqueline
    Rossi, Ethan
    Reecher, Hope
    Zhang, Min
    Bolch, Charlotte
    Putnam, Nicole
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [42] Adaptive optics scanning laser ophthalmoscope with integrated wide-field retinal imaging and tracking
    Ferguson, R. Daniel
    Zhong, Zhangyi
    Hammer, Daniel X.
    Mujat, Mircea
    Patel, Ankit H.
    Deng, Cong
    Zou, Weiyao
    Burns, Stephen A.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2010, 27 (11) : A265 - A277
  • [43] In vivo imaging of the human eye using a 2-photon-excited fluorescence scanning laser ophthalmoscope
    Boguslawski, Jakub
    Palczewska, Grazyna
    Tomczewski, Slawomir
    Milkiewicz, Jadwiga
    Kasprzycki, Piotr
    Stachowiak, Dorota
    Komar, Katarzyna
    Marzejon, Marcin J.
    Sikorski, Bartosz L.
    Hudzikowski, Arkadiusz
    Gluszek, Aleksander
    Laszczych, Zbigniew
    Karnowski, Karol
    Sobon, Grzegorz
    Palczewski, Krzysztof
    Wojtkowski, Maciej
    JOURNAL OF CLINICAL INVESTIGATION, 2022, 132 (02):
  • [44] Assessment of binocular fixational eye movements including cyclotorsion with split-field binocular scanning laser ophthalmoscopy
    Hofmann, Julia
    Domdei, Lennart
    Jainta, Stephanie
    Harmening, Wolf M.
    JOURNAL OF VISION, 2022, 22 (10):
  • [45] Scanning laser ophthalmoscope-particle tracking method to assess blood velocity during hypoxia and hyperoxia
    Lorentz, Kristen
    Zayas-Santiago, Astrid
    Tummala, Shanti
    Derwent, Jennifer J. Kang
    OXYGEN TRANSPORT TO TISSUE XXIX, 2008, 614 : 253 - 261
  • [46] High-Resolution Eye Tracking Using Scanning Laser Ophthalmoscopy
    Bowers, Norick R.
    Gibaldi, Agostino
    Alexander, Emma
    Banks, Martin S.
    Roorda, Austin
    ETRA 2019: 2019 ACM SYMPOSIUM ON EYE TRACKING RESEARCH & APPLICATIONS, 2019,
  • [47] REACTION-TIME TO MOTION OFFSET DURING EYE TRACKING
    GOUREVICH, A
    DIMITROV, G
    MITRANI, L
    PERCEPTION, 1989, 18 (04) : 500 - 500
  • [48] High-resolution, ultrafast, wide-field retinal eye-tracking for enhanced quantification of fixational and saccadic motion
    Bartuzel, Maciej M.
    Wrobel, Krystian
    Tamborski, Szymon
    Meina, Michal
    Nowakowski, Maciej
    Dalasinski, Krzysztof
    Szkulmowska, Anna
    Szkulmowski, Maciej
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (06): : 3164 - 3180
  • [49] Scanning mid-IR laser apparatus with eye tracking for refractive surgery
    Telfair, WB
    Yoder, PR
    Bekker, C
    Hoffman, HJ
    Jensen, EF
    OPHTHALMIC TECHNOLOGIES IX, PROCEEDINGS OF, 1999, 3591 : 220 - 228
  • [50] (Eye) tracking short-term memory over time
    Papagno, C.
    Bricolo, E.
    Mussi, D.
    Daini, R.
    Cecchetto, C.
    APHASIOLOGY, 2012, 26 (3-4) : 536 - 555