Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope

被引:2
|
作者
Montes, Shivany Y. Condor [1 ]
Bennett, Daniel [1 ]
Bensinger, Ethan [2 ,3 ]
Rani, Lakshmisahithi [1 ]
Sherkat, Younes [4 ]
Zhao, Chao [1 ]
Helft, Zachary [5 ]
Roorda, Austin [2 ,3 ]
Green, Ari J. [1 ,6 ]
Sheehy, Christy K. [1 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Neurol, San Francisco, CA USA
[2] Univ Calif Berkeley, Vis Sci Grad Grp, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[4] Univ Calif Berkeley, Coll Engn, Berkeley, CA 94720 USA
[5] C Light Technol Inc, Berkeley, CA USA
[6] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
来源
基金
美国国家卫生研究院;
关键词
fixational eye motion; microsaccades; retinal eye-tracking; OCULAR DRIFT; MICROSACCADES; SACCADES; VISION;
D O I
10.1167/tvst.11.2.35
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to characterize the benign biological variance of fixational microsaccades in a control population using a tracking scanning laser ophthalmoscope (TSLO), accounting for machine accuracy and precision, to determine ideal testing conditions to detect pathologic change in fixational eye motion (FEM). Methods: We quantified the accuracy and precision of the TSLO, analyzing measurements made by three operators on a model eye. Repeated, 10-second retinal motion traces were then recorded in 17 controls, 3 times a day (morning, afternoon, and evening), on 3 separate days. Microsaccade metrics (MMs) of frequency, average amplitude, peak velocity, and peak acceleration were extracted. Trace to trace, interday, and intraday variability were calculated across all subjects. Results: Intra-operator and machine variation contributed minimally to total variation, with only 0.007% and 0.14% contribution for frequency and amplitude respectively. Bias was detected, with lower accuracy for higher amplitudes. Participants had an average (SD) microsaccade frequency of 0.84 Hz (0.52 Hz), amplitude of 0.32 degrees (0.11 degrees), peak velocity of 43.68 degrees/s (14.02 degrees/s), and peak acceleration of 13,920.04 degrees/s2 (4,186.84 degrees/s2). The first trace recorded within a session significantly differed from the second two in both microsaccade acceleration and velocity (P < 0.05), and frequency was 0.098 Hz higher in the evenings (P < 0.05). There was no MM difference between days and no evidence of a session-level learning effect (P > 0.05). Conclusions: The TSLO is both accurate and precise. However, biological inter- and intra-individual variance is present. Trace to trace variability and time of day should be accounted for to optimize detection of pathologic change.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Tracking adaptive optics scanning laser ophthalmoscope (TAOSLO)
    Hammer, DX
    Ferguson, RD
    Iftimia, NV
    Ustun, T
    Burns, SA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [22] Repeatability, Reproducibility, and Bias of the Tracking Scanning Laser Ophthalmoscope
    Condor-Montes, Shivany
    Sheehy, Christy
    Bensinger, Ethan
    Sherkat, Younes
    Helft, Zachary
    Roorda, Austin John
    Green, Ari J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [23] Scanning Laser Ophthalmoscope Imaging is a diagnostic predictor of Dry Eye
    Espina, Mark
    Arcinue, Cheryl A.
    Camacho, Natalia
    Alam, Mostafa
    You, Qisheng
    Gomez, Maria Laura
    Bartsch, Dirk-Uwe G.
    Cheng, Lingyun
    Afshari, Natalie A.
    Freeman, William R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [24] Precision targeting with a tracking adaptive optics scanning laser ophthalmoscope
    Hammer, Daniel X.
    Ferguson, R. Daniel
    Bigelow, Chad E.
    Iftimia, Nicusor V.
    Ustun, Teoman E.
    Noojin, Gary D.
    Stolarski, David J.
    Hodnett, Harvey M.
    Imholte, Michelle L.
    Kumru, Semih S.
    McCall, Michelle N.
    Toth, Cynthia A.
    Rockwell, Benjamin A.
    OPHTHALMIC TECHNOLOGIES XVI, 2006, 6138
  • [25] MEASUREMENT OF FIXATIONAL STABILITY WHILE PERFORMING A HYPERACUITY TASK USING THE SCANNING LASER OPHTHALMOSCOPE - PRELIMINARY STUDIES
    LAKSHMINARAYANAN, V
    KNOWLES, RA
    ENOCH, JM
    VASUDEVAN, R
    CLINICAL VISION SCIENCES, 1992, 7 (06): : 557 - 563
  • [26] Scanning eye movements in homonymous hemianopia documented by scanning laser ophthalmoscope retinal perimetry
    Jamara, RJ
    Van de velde, F
    Peli, E
    OPTOMETRY AND VISION SCIENCE, 2003, 80 (07) : 495 - 504
  • [27] A scanning laser ophthalmoscope for use with correction for the eye's wave aberrations
    Burns, SA
    Webb, RH
    Elsner, AE
    Marcos, S
    Bara, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U209 - U209
  • [28] Tracking scanning laser ophthalmoscope (TSLO): Initial human subject testing
    Hammer, DX
    Ferguson, RD
    Magill, JC
    Elsner, AF
    Webb, RH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U1260 - U1260
  • [29] High resolution Scanning Laser Ophthalmoscope imaging with ultrafast retinal tracking
    Szkulmowski, Maciej
    Nowakowski, Maciej
    Dalasinski, Krzysztof
    Bartuzel, Maciej M.
    Wrobel, Krystian
    Tamborski, Szymon
    Pijewska, Ewelina
    Szkulmowska, Anna
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [30] Motion-compensated blind deconvolution of scanning laser ophthalmoscope imagery
    O'Connor, NJ
    Bartsch, DU
    Freeman, W
    Holmes, TJ
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING V, PROCEEDINGS OF, 1998, 3261 : 71 - 87