Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope

被引:2
|
作者
Montes, Shivany Y. Condor [1 ]
Bennett, Daniel [1 ]
Bensinger, Ethan [2 ,3 ]
Rani, Lakshmisahithi [1 ]
Sherkat, Younes [4 ]
Zhao, Chao [1 ]
Helft, Zachary [5 ]
Roorda, Austin [2 ,3 ]
Green, Ari J. [1 ,6 ]
Sheehy, Christy K. [1 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Neurol, San Francisco, CA USA
[2] Univ Calif Berkeley, Vis Sci Grad Grp, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[4] Univ Calif Berkeley, Coll Engn, Berkeley, CA 94720 USA
[5] C Light Technol Inc, Berkeley, CA USA
[6] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
来源
基金
美国国家卫生研究院;
关键词
fixational eye motion; microsaccades; retinal eye-tracking; OCULAR DRIFT; MICROSACCADES; SACCADES; VISION;
D O I
10.1167/tvst.11.2.35
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to characterize the benign biological variance of fixational microsaccades in a control population using a tracking scanning laser ophthalmoscope (TSLO), accounting for machine accuracy and precision, to determine ideal testing conditions to detect pathologic change in fixational eye motion (FEM). Methods: We quantified the accuracy and precision of the TSLO, analyzing measurements made by three operators on a model eye. Repeated, 10-second retinal motion traces were then recorded in 17 controls, 3 times a day (morning, afternoon, and evening), on 3 separate days. Microsaccade metrics (MMs) of frequency, average amplitude, peak velocity, and peak acceleration were extracted. Trace to trace, interday, and intraday variability were calculated across all subjects. Results: Intra-operator and machine variation contributed minimally to total variation, with only 0.007% and 0.14% contribution for frequency and amplitude respectively. Bias was detected, with lower accuracy for higher amplitudes. Participants had an average (SD) microsaccade frequency of 0.84 Hz (0.52 Hz), amplitude of 0.32 degrees (0.11 degrees), peak velocity of 43.68 degrees/s (14.02 degrees/s), and peak acceleration of 13,920.04 degrees/s2 (4,186.84 degrees/s2). The first trace recorded within a session significantly differed from the second two in both microsaccade acceleration and velocity (P < 0.05), and frequency was 0.098 Hz higher in the evenings (P < 0.05). There was no MM difference between days and no evidence of a session-level learning effect (P > 0.05). Conclusions: The TSLO is both accurate and precise. However, biological inter- and intra-individual variance is present. Trace to trace variability and time of day should be accounted for to optimize detection of pathologic change.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Characterizing image quality in a scanning laser ophthalmoscope with differing pinholes and induced scattered light
    Hunter, Jennifer J.
    Cookson, Christopher J.
    Kisilak, Marsha L.
    Bueno, Juan M.
    Campbell, Melanie C. W.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) : 1284 - 1295
  • [32] Wide-field retinal hemodynamic imaging with the tracking scanning laser ophthalmoscope
    Ferguson, RD
    Hammer, DX
    Elsner, AE
    Webb, RH
    Burns, SA
    OPTICS EXPRESS, 2004, 12 (21): : 5198 - 5208
  • [33] Realtime tracking and averaging with the HRA 2 digital confocal scanning laser ophthalmoscope
    Gentsch, D
    Fendrich, T
    Otto, T
    Wiedemann, P
    Wolf, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [34] Real Time In Vivo Tracking of Thymocytes in the Anterior Chamber of the Eye by Laser Scanning Microscopy
    Oltra, Elisa
    Caicedo, Alejandro
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (140):
  • [35] In vivo retinal imaging for fixational eye motion detection using a high-speed digital micromirror device (DMD)-based ophthalmoscope
    Vienola, Karl V.
    Damodaran, Mathi
    Braaf, Boy
    Vermeer, Koenraad A.
    de Boer, Johannes F.
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (02): : 591 - 602
  • [36] Retinal sensitivity measurement over drusen using scanning laser ophthalmoscope microperimetry
    Y. Takamine
    Kunihiko Shiraki
    Mitsuyasu Moriwaki
    Takaharu Yasunari
    Tokuhiko Miki
    Graefe's Archive for Clinical and Experimental Ophthalmology, 1998, 236 : 285 - 290
  • [37] A new approach to retinal tracking for image stabilization: initial results for the scanning laser ophthalmoscope
    Ferguson, RD
    Elsner, AE
    Webb, RH
    VISION SCIENCE AND ITS APPLICATIONS, PROCEEDINGS, 2000, 35 : 302 - 305
  • [38] Fluorescent infrared scanning-laser ophthalmoscope for three-dimensional visualization: automatic random-eye-motion correction and deconvolution
    O'Connor, NJ
    Bartsch, DU
    Freeman, WJ
    Mueller, AJ
    Holmes, TJ
    APPLIED OPTICS, 1998, 37 (11) : 2021 - 2033
  • [39] Wide-field stabilized Doppler flowmetry with the tracking scanning laser ophthalmoscope (TSLO)
    Ferguson, RD
    Hammer, DX
    Elsner, AE
    Burns, SA
    Webb, RH
    Weiter, JJ
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 170 - 178
  • [40] A compact fundus image guided adaptive optics scanning laser ophthalmoscope (AOSLO) imaging system with active eye tracking designed for clinical use
    Ren, Ji
    Yin, Qi
    Fu, Peng
    Li, Kaiwen
    Liu, Ruoyang
    Zhang, Teng
    Fan, Weixiao
    Zhou, Kang
    Liu, Qian
    Lei, Bo
    Yao, Jin
    Zhang, Jie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)