Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope

被引:2
|
作者
Montes, Shivany Y. Condor [1 ]
Bennett, Daniel [1 ]
Bensinger, Ethan [2 ,3 ]
Rani, Lakshmisahithi [1 ]
Sherkat, Younes [4 ]
Zhao, Chao [1 ]
Helft, Zachary [5 ]
Roorda, Austin [2 ,3 ]
Green, Ari J. [1 ,6 ]
Sheehy, Christy K. [1 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Neurol, San Francisco, CA USA
[2] Univ Calif Berkeley, Vis Sci Grad Grp, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[4] Univ Calif Berkeley, Coll Engn, Berkeley, CA 94720 USA
[5] C Light Technol Inc, Berkeley, CA USA
[6] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
来源
基金
美国国家卫生研究院;
关键词
fixational eye motion; microsaccades; retinal eye-tracking; OCULAR DRIFT; MICROSACCADES; SACCADES; VISION;
D O I
10.1167/tvst.11.2.35
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to characterize the benign biological variance of fixational microsaccades in a control population using a tracking scanning laser ophthalmoscope (TSLO), accounting for machine accuracy and precision, to determine ideal testing conditions to detect pathologic change in fixational eye motion (FEM). Methods: We quantified the accuracy and precision of the TSLO, analyzing measurements made by three operators on a model eye. Repeated, 10-second retinal motion traces were then recorded in 17 controls, 3 times a day (morning, afternoon, and evening), on 3 separate days. Microsaccade metrics (MMs) of frequency, average amplitude, peak velocity, and peak acceleration were extracted. Trace to trace, interday, and intraday variability were calculated across all subjects. Results: Intra-operator and machine variation contributed minimally to total variation, with only 0.007% and 0.14% contribution for frequency and amplitude respectively. Bias was detected, with lower accuracy for higher amplitudes. Participants had an average (SD) microsaccade frequency of 0.84 Hz (0.52 Hz), amplitude of 0.32 degrees (0.11 degrees), peak velocity of 43.68 degrees/s (14.02 degrees/s), and peak acceleration of 13,920.04 degrees/s2 (4,186.84 degrees/s2). The first trace recorded within a session significantly differed from the second two in both microsaccade acceleration and velocity (P < 0.05), and frequency was 0.098 Hz higher in the evenings (P < 0.05). There was no MM difference between days and no evidence of a session-level learning effect (P > 0.05). Conclusions: The TSLO is both accurate and precise. However, biological inter- and intra-individual variance is present. Trace to trace variability and time of day should be accounted for to optimize detection of pathologic change.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] The impact of caffeine on fixational eye motion and blink rate measured with a tracking scanning laser ophthalmoscope
    Theis, Jacqueline
    Nunez, Yessica
    Sheehy, Christy
    Rossi, Ethan A.
    Kozlowski, Michael R.
    Vasudevan, Balamurali
    Seaman, Julia E.
    Allen, Isabel Elaine
    Zhang, Min
    Putnam, Nicole M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (09)
  • [2] Binocular eye tracking with the Tracking Scanning Laser Ophthalmoscope
    Stevenson, S. B.
    Sheehy, C. K.
    Roorda, A.
    VISION RESEARCH, 2016, 118 : 98 - 104
  • [3] Tracking retinal motion with a scanning laser ophthalmoscope
    Xu, ZH
    Schuchard, R
    Ross, D
    Benkeser, P
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2005, 42 (03): : 373 - 380
  • [4] Microsaccades as recorded by the tracking scanning laser ophthalmoscope are associated with disability in MS
    Sheehy, Christy K.
    Bensinger, Ethan
    Devereux, Michael P.
    Baker, Nicholas S.
    Boehm, Alexandra E.
    Stevenson, Scott
    Green, Ari J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [5] Ultrafast Scanning Laser Ophthalmoscope for retinal tracking and on-line correction of the eye motion artifacts
    Szkulmowski, Maciej
    Nowakowski, Maciej
    Dalasinski, Krzysztof
    Bartuzel, Maciej M.
    Wrobel, Krystian
    Tamborski, Szymon
    Pijewska, Ewelina
    Szkulmowska, Anna
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [6] Binocular properties of fixational eye movements as assessed using a high resolution binocular scanning laser ophthalmoscope
    Chung, Susana T. L.
    Li, Roger W.
    Agaoglu, Mehmet N.
    Tiruveedhula, Pavan K.
    Roorda, Austin John
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [7] Active eye-tracking for an adaptive optics scanning laser ophthalmoscope
    Sheehy, Christy K.
    Tiruveedhula, Pavan
    Sabesan, Ramkumar
    Roorda, Austin
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (07): : 2412 - 2423
  • [8] Simultaneous eye tracking with a Tracking Scanning Laser Ophthalmoscope (TSLO) and a video-based eye tracker
    Prahalad, Krishnamachari S.
    Coates, Daniel R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [9] Binocular properties of fixational eye movements as assessed using a high-resolution binocular scanning laser ophthalmoscope
    Chung, Susana T. L.
    Li, Roger W.
    Agaoglu, Mehmet N.
    Tiruveedhula, Pavan Kumar
    Roorda, Austin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [10] Tracking scanning laser ophthalmoscope (TSLO)
    Hammer, DX
    Ferguson, RD
    Magill, JC
    White, MA
    Elsner, AE
    Webb, RH
    OPHTHALMIC TECHNOLOGIES XIII, 2003, 4951 : 208 - 217