Experimental investigation of the effect of collection length in a two-stage electrostatic precipitator for removal of PM2.5

被引:22
|
作者
Zhu, Yong [1 ]
Chen, Chen [1 ]
Shi, Jianwei [1 ]
Chen, Mingxia [1 ]
Shangguan, Wenfeng [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Res Ctr Combust & Environm Technol, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Two-stage ESP; Collection length; Sub-micron particle; Collection efficiency; Ozone concentration; FINE-PARTICLE; CHARGING CHARACTERISTICS; NUMERICAL-SIMULATION; CORONA DISCHARGE; ENHANCEMENT; EFFICIENCY; PERFORMANCE; CATALYSIS; CAPTURE;
D O I
10.1016/j.cej.2020.127797
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work, a laboratory-scale charger, with a single wire electrode of one charging unit for effective ozone control, and collector with a 300 mm length and 5 mm plate-plate distance extremely short for high-efficient capture of noxious particles, was designed and assembled as a two-stage ESP to study the effect of collection length for removal of PM2.5, in particular to these sub-micron particles which had the highest penetration rate during the electrostatic capture process. The influence factors, including the current density of charger, the electric field strength of collector, and gas velocity, were investigated in detail. Multiple channels of the collector were chosen to thoroughly compare the performance difference by detecting the particle concentration in the electric field directly. Besides, the ozone concentration test was carried out in various parameters to explore the influence degree simultaneously. Experimental results showed that the collection efficiency based on the number concentration could reach up to be 92.9%, 96.7%, and 97.7% for 0.25 mu m, 0.35 mu m, and 0.45 mu m diameter particles at 4 m/s gas velocity, respectively, which benefited from the advantages of long collection plate and short migration distance. Compared with the influence factors of charger current density and gas velocity, electric field strength occupied the middle position in effecting the collection efficiency, whose most massive index factor was about 18 at a collection length of 30 cm. While the maximum index factor of current density was 3.7 at a collection length of 15 cm and of gas velocity was 27.5 at a collection length of 10 cm. The ozone concentration test suggested that charger current, gas velocity, collection length, and electric field strength could affect the ozone concentration from strong to weak in sequence.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Field Measurements on the Emission and Removal of PM2.5 from Coal-Fired Power Stations: 2. Studies on Two 135 MW Circulating Fluidized Bed Boilers Respectively Equipped with an Electrostatic Precipitator and a Hybrid Electrostatic Filter Precipitator
    Liu, Xiaowei
    Xu, Yishu
    Fan, Bin
    Lv, Chen
    Xu, Minghou
    Pan, Siwei
    Zhang, Kai
    Li, Li
    Gao, Xiangpeng
    ENERGY & FUELS, 2016, 30 (07) : 5922 - 5929
  • [42] A Two-Stage Virtual Impactor for In-Stack Sampling of PM2.5 and PM10 in Flue Gas of Stationary Sources
    Wada, Masashi
    Tsukada, Mayumi
    Namiki, Norikazu
    Szymanski, Wladyslaw W.
    Noda, Naoki
    Makino, Hisao
    Kanaoka, Chikao
    Kamiya, Hidehiro
    AEROSOL AND AIR QUALITY RESEARCH, 2016, 16 (01) : 36 - 45
  • [43] Two-stage electrostatic precipitator with co- and counter-flow particle prechargers
    Jaworek, A.
    Marchewicz, A.
    Sobczyk, A. T.
    Krupa, A.
    Czech, T.
    JOURNAL OF ELECTROSTATICS, 2017, 87 : 180 - 194
  • [44] Particle removal performance of a two stage electrostatic precipitator with carbon based non-metallic collection plates for oil mist
    Lee, Yeawan
    Sung, Jin-Ho
    Han, Bangwoo
    Kim, Yong-Jin
    Kim, Hak-Joon
    2020 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2020,
  • [45] Investigation of the Arrayed Dielectric Barrier Discharge Reactor for PM2.5 Removal in Air
    Huang, Xiutao
    Guo, Fu
    Chen, Junfeng
    Wang, Shengming
    Hu, Zhaoyang
    Wang, Lele
    Chen, Zhaoquan
    Liu, Minghai
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (08) : 1341 - 1348
  • [46] Study of the multi-physics field-coupled model of the two-stage electrostatic precipitator
    Wenjia Hao
    Yu Guo
    Yukun Wang
    Tao Yu
    Hao Gao
    Zhengwei Long
    Building Simulation, 2024, 17 : 387 - 398
  • [47] Study of the multi-physics field-coupled model of the two-stage electrostatic precipitator
    Hao, Wenjia
    Guo, Yu
    Wang, Yukun
    Yu, Tao
    Gao, Hao
    Long, Zhengwei
    BUILDING SIMULATION, 2024, 17 (03) : 387 - 398
  • [48] Experimental and modeling assessment of a novel automotive cabin PM2.5 removal system
    Vande Hey, Joshua D.
    Sonderfeld, Hannah
    Jeanjean, Antoine P. R.
    Panchal, Rikesh
    Leigh, Roland J.
    Allen, Mark A.
    Dawson, Mark
    Monks, Paul S.
    AEROSOL SCIENCE AND TECHNOLOGY, 2018, 52 (11) : 1249 - 1265
  • [49] Experimental study on removal of PM2.5 from combustion by vapor heterogeneous condensation
    Zhang, Xia
    Yang, Linjun
    Sun, Lujuan
    Zhang, Yu
    Yan, Jinpei
    Shen, Xianglin
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2008, 38 (01): : 81 - 85
  • [50] Experimental study on PM2.5 removal by magnetic polyimide loaded with cobalt ferrate
    Zhou F.
    Diao Y.
    Wang R.
    Yang B.
    Zhang T.
    Energy and Built Environment, 2020, 1 (04): : 404 - 409