Experimental investigation of the effect of collection length in a two-stage electrostatic precipitator for removal of PM2.5

被引:22
|
作者
Zhu, Yong [1 ]
Chen, Chen [1 ]
Shi, Jianwei [1 ]
Chen, Mingxia [1 ]
Shangguan, Wenfeng [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Res Ctr Combust & Environm Technol, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Two-stage ESP; Collection length; Sub-micron particle; Collection efficiency; Ozone concentration; FINE-PARTICLE; CHARGING CHARACTERISTICS; NUMERICAL-SIMULATION; CORONA DISCHARGE; ENHANCEMENT; EFFICIENCY; PERFORMANCE; CATALYSIS; CAPTURE;
D O I
10.1016/j.cej.2020.127797
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work, a laboratory-scale charger, with a single wire electrode of one charging unit for effective ozone control, and collector with a 300 mm length and 5 mm plate-plate distance extremely short for high-efficient capture of noxious particles, was designed and assembled as a two-stage ESP to study the effect of collection length for removal of PM2.5, in particular to these sub-micron particles which had the highest penetration rate during the electrostatic capture process. The influence factors, including the current density of charger, the electric field strength of collector, and gas velocity, were investigated in detail. Multiple channels of the collector were chosen to thoroughly compare the performance difference by detecting the particle concentration in the electric field directly. Besides, the ozone concentration test was carried out in various parameters to explore the influence degree simultaneously. Experimental results showed that the collection efficiency based on the number concentration could reach up to be 92.9%, 96.7%, and 97.7% for 0.25 mu m, 0.35 mu m, and 0.45 mu m diameter particles at 4 m/s gas velocity, respectively, which benefited from the advantages of long collection plate and short migration distance. Compared with the influence factors of charger current density and gas velocity, electric field strength occupied the middle position in effecting the collection efficiency, whose most massive index factor was about 18 at a collection length of 30 cm. While the maximum index factor of current density was 3.7 at a collection length of 15 cm and of gas velocity was 27.5 at a collection length of 10 cm. The ozone concentration test suggested that charger current, gas velocity, collection length, and electric field strength could affect the ozone concentration from strong to weak in sequence.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Comprehensive control of PM 2.5 capture and ozone emission in two-stage electrostatic precipitators
    Zhu, Yong
    Wei, Zhidong
    Yang, Xiaoyong
    Tao, Shanlong
    Zhang, Yikun
    Shangguan, Wenfeng
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 858
  • [22] Effects of pre-charger length, symmetry and insertion depth on PM2.5 removal efficiency for electrostatic precipitator (ESP)-type wearable personal air cleaner
    Munir, Muhammad Hanzla
    An, Sohee
    Lee, Gwangtaek
    Kim, Hak-Joon
    JOURNAL OF ELECTROSTATICS, 2025, 135
  • [23] AN IMPROVED MODELING FOR PREDICTION OF PM2.5 COLLECTION EFFICIENCY IN ELECTROSTATIC PRECIPITATORS
    Zhang, Jian-Ping
    Gong, Zhen
    Wu, Jiong-Lei
    Wu, Helen
    Pan, Wei-Guo
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2018, 17 (03): : 631 - 640
  • [24] Investigation of two-stage type electrostatic precipitator reentrainment phenomena under diesel flue gases
    Zukeran, A
    Ikeda, Y
    Ehara, Y
    Ito, T
    Takahashi, T
    Kawakami, H
    IAS '97 - CONFERENCE RECORD OF THE 1997 IEEE INDUSTRY APPLICATIONS CONFERENCE / THIRTY-SECOND IAS ANNUAL MEETING, VOLS 1-3, 1997, : 1737 - 1743
  • [25] Fine particle removal by a two-stage electrostatic precipitator with multiple ion-injection-type prechargers
    Kim, Hak-Joon
    Kim, Myungjoon
    Han, Bangwoo
    Woo, Chang Gyu
    Zouaghi, Ayyoub
    Zouzou, Noureddine
    Kim, Yong-Jin
    JOURNAL OF AEROSOL SCIENCE, 2019, 130 : 61 - 75
  • [26] Fine particle removal by a two-stage electrostatic precipitator with multiple ion-injection-type prechargers
    Kim, Hak-Joon
    Kim, Myungjoon
    Han, Bangwoo
    Woo, Chang Gyu
    Zouaghi, Ayyoub
    Zouzou, Noureddine
    Kim, Yong-Jin
    Journal of Aerosol Science, 2019, 130 : 61 - 75
  • [27] Experimental investigation on particle collection performance of electrostatic precipitator at high temperatures
    State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou
    310027, China
    Zhongguo Huanjing Kexue, 4 (1009-1016):
  • [28] Corona discharge characteristics of cylindrical electrodes in a two-stage electrostatic precipitator
    Wen, Tsrong-Yi
    Su, Jiann-Lin
    HELIYON, 2020, 6 (02)
  • [29] Performance Evaluation of a Three Stage Electrostatic Precipitation System for Collection of Particulate Matter less than PM2.5
    Jhunjhunwala, Sanket
    Sehrawat, Sumeet
    Pandey, Kamlesh
    PROCEEDINGS OF THE 2018 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), 2018, : 369 - 371
  • [30] Influences of temperature and magnetic field on PM2.5 collection performance of electrostatic precipitators
    Zhang, Jianping
    Wang, Jiahan
    Chen, Zhuo
    Zhang, Pengju
    Liu, Ping
    FUEL, 2024, 366