A Two-Stage Virtual Impactor for In-Stack Sampling of PM2.5 and PM10 in Flue Gas of Stationary Sources

被引:21
|
作者
Wada, Masashi [1 ]
Tsukada, Mayumi [2 ]
Namiki, Norikazu [3 ]
Szymanski, Wladyslaw W. [4 ]
Noda, Naoki [5 ]
Makino, Hisao [5 ]
Kanaoka, Chikao [1 ]
Kamiya, Hidehiro [2 ]
机构
[1] Ishikawa Coll, Natl Inst Technol, Dept Civil Engn, Tsubata, Ishikawa 9290392, Japan
[2] Tokyo Univ Agr & Technol, Inst Engn, Koganei, Tokyo 1848588, Japan
[3] Kogakuin Univ, Dept Environm & Energy Chem, Tokyo 1920015, Japan
[4] Univ Vienna, Fac Phys, Boltzmanngasse 5, A-1090 Vienna, Austria
[5] Cent Res Inst Elect Power Ind, Kanagawa 2400196, Japan
关键词
PM2.5; PM10; Mass concentration; Stationary sources; Virtual impactor; Conventional impactor; Particle bounce; CASCADE IMPACTOR; COLLECTION CHARACTERISTICS; COMBUSTION AEROSOLS; FINE PARTICLES; AIR-POLLUTION; SIZE; EFFICIENCY; EMISSIONS;
D O I
10.4209/aaqr.2015.06.0383
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two ISO standard methods for in-stack sampling and measurement of PM2.5 and PM10 mass concentrations in flue gas from stationary sources were published in 2009 (ISO 23210, conventional cascade impactors) and 2012 (ISO 13271, virtual impactors). The performances of these two methods in terms of PM2.5 separation efficiency and the accuracy of measured mass concentration were compared at the same sampling point and conditions both using laboratory-scale model flue gas with different dust concentrations and using real flue gas sampled from a test facility for pulverized coal combustion. The virtual impactor showed very satisfactory performance for PM2.5 mass concentration and separation efficiency within the investigated range of mass concentrations and ambient conditions. The conventional cascade impactor method overestimated PM2.5 mass concentration by more than 25% due to particle bounce and re-entrainment of coarse particles from the collection plates. During in-stack PM2.5 sampling from coal combustion flue gas with reactive components at high temperature, the use of greased plates with the conventional impactor caused overestimation of mass concentration, even when grease with high temperature endurance was used. The use of a quartz-fiber filters on the impaction plates reduced overestimation but particle bounce and re-entrainment still remained.
引用
收藏
页码:36 / 45
页数:10
相关论文
共 50 条
  • [1] Development of a PM 10/PM 2.5 cascade impactor and in-stack measurements
    John, AC
    Kuhlbusch, TAJ
    Fissan, H
    Bröker, G
    Geueke, KJ
    AEROSOL SCIENCE AND TECHNOLOGY, 2003, 37 (09) : 694 - 702
  • [2] Development of a PM 10/PM 2.5 cascade impactor for in-stack measurements
    John, A.C.
    Kuhlbusch, T.A.J.
    Fißan, H.
    Bröker, G.
    Geueke, K.-J.
    Gefahrstoffe Reinhaltung der Luft, 59 (11-12): : 449 - 454
  • [3] Development of a PM 10/PM 2.5 cascade impactor for in-stack measurements
    John, AC
    Kuhlbusch, TAJ
    Fissan, H
    Bröker, G
    Geueke, KJ
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 1999, 59 (11-12): : 449 - 454
  • [4] The Characterization of PM, PM10, and PM2.5 from Stationary Sources
    Kim, JongHo
    Hwang, InJo
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2016, 32 (06) : 603 - 612
  • [5] Development of PM10 and PM2.5 cyclones for small sampling ports at stationary sources: Numerical and experimental study
    Youn, Jong-Sang
    Han, Sehyun
    Yi, Jae-Seong
    Kang, Dae-Il
    Jang, Kee-Won
    Jung, Yong-Won
    Park, Young-Kwon
    Jeon, Ki-Joon
    ENVIRONMENTAL RESEARCH, 2021, 193
  • [6] Performance of EPA stack sampling methods for PM10, PM2.5 and condensible particulate matter on sources equipped with electrostatic precipitators
    Rovell-Rixx, David
    NCASI Technical Bulletin, 2002, (852): : 1 - 63
  • [7] Emission and profile characteristic of polycyclic aromatic hydrocarbons in PM2.5 and PM10 from stationary sources based on dilution sampling
    Kong, Shaofei
    Ji, Yaqin
    Li, Zhiyong
    Lu, Bing
    Bai, Zhipeng
    ATMOSPHERIC ENVIRONMENT, 2013, 77 : 155 - 165
  • [8] Sources of PM10 and PM2.5 in Cairo’s ambient air
    M. Abu-Allaban
    D. H. Lowenthal
    A. W. Gertler
    M. Labib
    Environmental Monitoring and Assessment, 2007, 133 : 417 - 425
  • [9] Sources of PM10 and PM2.5 in Cairo's ambient air
    Abu-Allaban, M.
    Lowenthal, D. H.
    Gertler, A. W.
    Labib, M.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2007, 133 (1-3) : 417 - 425
  • [10] Characterization of PM10 and PM2.5 emission sources at Chennai, India
    Jose, Jithin
    Srimuruganandam, B.
    Nagendra, S.M. Shiva
    Nature Environment and Pollution Technology, 2019, 18 (02) : 555 - 562