Ahmed glaucoma valve in vitrectomized eyes: An implantation technique to minimize early postoperative fluid-loss hypotony

被引:4
|
作者
Arpa, Paolo [1 ]
Arpa, Cristina [2 ]
机构
[1] ASST Vimercate, Vimercate Hosp, Monza, Italy
[2] Moorfields Eye Hosp NHS Fdn Trust, London, England
关键词
Aqueous humor dynamics; glaucoma; tube shunts; neovascular glaucoma; pars plana vitrectomy; vitreous; endophthalmitis; pathologic myopia; retina; CLINICAL-EXPERIENCE; PATCH GRAFT;
D O I
10.1177/11206721211012200
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the application of a modified Ahmed glaucoma valve (AGV) surgical implantation technique in vitrectomized eyes, in order to minimize the risk of early postoperative hypotony, which leads to hemorrhagic complications. Materials and methods: Data of patients implanted with AGV using the surgical technique described were retrospectively reviewed. Inclusion criterion: glaucomatous eyes with previous history of pars plana vitrectomy. Intraocular pressure (IOP) measurement and ophthalmic examination were performed preoperatively and postoperatively weekly for 1 month for the detection of early hypotony, choroidal effusion/detachment, intraocular hemorrhage. The surgical technique consisted in creating a 5 mm long scleral tunnel with a 23 G needle reaching the anterior chamber at the iridocorneal angle, in which the Ahmed glaucoma valve tube was inserted. Results: Ten eyes of 10 patients were included. Median preoperative IOP was 30.5 mmHg [interquartile range (IQR) 28.3-33.0]; median postoperative IOP was 12.0 mmHg (IQR 9.3-13.0) at 1 week, and 12.5 mmHg (IQR 11.0-15.0) at 1 month. In no cases postoperative IOP was <8 mmHg. On the first postoperative day, five (50%) eyes showed few blood clots in the anterior chamber. On the second-week appointment, moderate choroidal effusion was observed in two eyes (20%). No hemorrhagic complications were observed. Conclusions: The creation of a long intrascleral tunnel with a 23 G needle for AGV implantation in vitrectomized eyes could be effective in decreasing leakage through the space between the valve tube and the sclerocorneal tissue. This technique is safe, easy to perform, feasible and fast. Due to its advantages and good postoperative results, it could also be adopted in non-vitrectomized eyes.
引用
收藏
页码:2759 / 2764
页数:6
相关论文
共 50 条
  • [31] A scleral tunnel graft-free technique in Ahmed glaucoma valve (AGV) implantation
    Lim, Rongxuan
    Karydis, Andreas
    Taylor, Simon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [32] Comparison of Tenon duplication with dura mater covering technique for Ahmed glaucoma valve implantation
    Erol, Mehmet Akif
    Demirdizen, Duygu Oren
    Simsek, Tulay
    Yildirim, Nilgun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 3) : S404 - S408
  • [33] Surgical Outcomes of Ahmed Glaucoma Valve Implantation with Postoperative Use of Prednisolone Acetate versus Difluprednate
    Kao, Brandon W.
    Fong, Christopher W.
    Yu, Yinxi
    Ying, Gui-Shuang
    Gedde, Steve J.
    Han, Ying
    OPHTHALMOLOGY GLAUCOMA, 2022, 5 (05): : 468 - 475
  • [34] Evaluation of early ocular discomfort after glaucoma surgery: trabeculectomy versus Ahmed glaucoma valve implantation
    Abe, Ricardo Y.
    Yamamoto, Douglas R.
    Souto, Fernanda Maria Silveira
    Vasconcellos, Jose Paulo Cabral
    Costa, Vital Paulino
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2024, 87 (03) : e20230033
  • [35] Autologous Scleral Pocket Technique for Ahmed Glaucoma Valve Implantation with Pars Plana Tube Insertion for Neovascular Glaucoma
    Maki, Hitomi
    Mori, Sotaro
    Imai, Hisanori
    Yamada, Hiroko
    Otsuka, Keiko
    Miki, Akiko
    Kusuhara, Sentaro
    Nakamura, Makoto
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (08)
  • [36] Baerveldt or Ahmed glaucoma valve implantation with pars plana tube insertion in Japanese eyes with neovascular glaucoma: I -year outcomes
    Suda, Masayo
    Nakanishi, Hideo
    Akagi, Tadamichi
    Murakami, Tomoaki
    Suzuma, Kiyoshi
    Suda, Kenji
    Kameda, Takanori
    Morooka, Satoshi
    Ikeda, Hanako Ohashi
    Tsujikawa, Akitaka
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 2439 - 2449
  • [37] Effect of Postoperative Trimming of the Tube Portion of Ahmed Glaucoma Valve on Corneal Endothelial Cell Loss
    Lee, Ko Eun
    Sung, Kyung Rim
    Shin, Joong Won
    JOURNAL OF GLAUCOMA, 2022, 31 (02) : 102 - 108
  • [38] Clinical outcomes of Ahmed glaucoma valve implantation without fixation of a plate: The free plate technique
    Lee, Han Min
    Park, Kee Sup
    Jeon, Yoo Young
    Kim, Woo Jin
    Lee, Nam Ho
    Kim, Kyoung Nam
    Kim, Chang-sik
    PLOS ONE, 2020, 15 (11):
  • [39] Value of Intravitreal Gas Injection With Ahmed Valve Implantation in the Prevention of Suprachoroidal Hemorrhage in Aphakic, Aniridic, and Vitrectomized Glaucomatous Eyes: A Pilot Study
    El-Saied, Heba M. A.
    Adullatif, Abdussalam M.
    JOURNAL OF GLAUCOMA, 2017, 26 (06) : E190 - E193
  • [40] Application of 5-Fluorouracil-Polycaprolactone Sustained-Release Film in Ahmed Glaucoma Valve Implantation Inhibits Postoperative Bleb Scarring in Rabbit Eyes
    Bi, Xiu-Zeng
    Pan, Wei-Hua
    Yu, Xin-Ping
    Song, Zong-Ming
    Ren, Zeng-Jin
    Sun, Min
    Li, Cong-Hui
    Nan, Kai-Hui
    PLOS ONE, 2015, 10 (11):