Comparison of Tenon duplication with dura mater covering technique for Ahmed glaucoma valve implantation

被引:0
|
作者
Erol, Mehmet Akif [1 ]
Demirdizen, Duygu Oren [2 ]
Simsek, Tulay [2 ]
Yildirim, Nilgun [2 ]
机构
[1] Kirklareli Univ, Fac Med, Dept Ophthalmol, Kirklareli, Turkiye
[2] Eskisehir Osmangazi Univ, Fac Med, Dept Ophthalmol, Eskisehir, Turkiye
关键词
Ahmed glaucoma valve implantation; dura mater covering technique; glaucoma; surgical technique; Tenon duplication technique; LONG-TERM OUTCOMES; TUBE EXPOSURE; RISK-FACTORS; MITOMYCIN-C; TRABECULECTOMY; PROGRESSION; EFFICACY; SURGERY; SAFETY;
D O I
10.4103/IJO.IJO_772_23
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To compare the efficacy and complications of Tenon duplication with dura mater covering technique for Ahmed glaucoma valve (AGV) implantation.Methods:This retrospective study included 44 refractory glaucoma patients (44 eyes) who underwent AGV implantation from 2017 to 2020 in the Ophthalmology Clinic of Eskisehir Osmangazi University Hospital and attended regular postoperative follow-ups. The patients were divided based on whether they underwent Tenon duplication technique (group 1: n = 20) or dura mater covering technique (group 2: n = 24) during surgery. The patients' age, gender, systemic diseases, glaucoma type, pre-op intraocular pressure (IOP), and ocular surgeries were recorded. The groups were compared for IOP level control, early and late complications, postoperative antiglaucomatous medication requirements, glaucoma surgery requirements, presence of postoperative hypertensive phase (HP), and surgical success which was defined as an IOP >= 5 and <= 21 mmHg, with or without antiglaucoma medication.Results:By the end of the mean follow-up (22.6 +/- 10.6 months), the success rates were 95% (group 1) and 96% (group 2). The groups showed no differences in postoperative complications, postoperative antiglaucomatous drugs' onset time, additional glaucoma surgery, need for needling, presence of HP at 6 months postoperatively, and relationship between the glaucoma type and success rates (P values: 0.86, 0.9, 0.48, 0.12, 0.36, and 0.8, respectively). The IOP values at the last follow-up were 15.2 +/- 4.1 in group 1 and 14.7 +/- 4.8 in group 2. The IOP reduction rates showed no significant differences.Conclusion:Since success and complications are similar in both Tenon duplication and dura mater covering technique, unique grafting materials may not be needed in AGV implantation surgery, except in special cases.
引用
收藏
页码:S404 / S408
页数:5
相关论文
共 50 条
  • [1] Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma
    Tamcelik, Nevbahar
    Ozkok, Ahmet
    Sarici, Ahmet Murat
    Atalay, Eray
    Yetik, Huseyin
    Gungor, Kivanc
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2013, 57 (04) : 359 - 364
  • [2] Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma
    Nevbahar Tamcelik
    Ahmet Ozkok
    Ahmet Murat Sarıcı
    Eray Atalay
    Huseyin Yetik
    Kivanc Gungor
    Japanese Journal of Ophthalmology, 2013, 57 : 359 - 364
  • [3] Supra-Tenon Capsule Implantation of the Ahmed Glaucoma Valve in Refractory Pediatric Glaucoma
    Elhefney, Eman M.
    Al-Sharkawy, Hossam T.
    Kishk, Hanem M.
    JOURNAL OF GLAUCOMA, 2016, 25 (09) : 732 - 737
  • [4] A novel surgical technique for prevention of Ahmed glaucoma valve tube exposure: long scleral flap augmented with Tenon advancement and duplication
    Totuk, O. M. Gedar
    Kabadayi, K.
    Colakoglu, A.
    Ekizoglu, N.
    Aykan, U.
    BMC OPHTHALMOLOGY, 2018, 18
  • [5] A novel surgical technique for prevention of Ahmed glaucoma valve tube exposure: long scleral flap augmented with Tenon advancement and duplication
    O. M. Gedar Totuk
    K. Kabadayi
    A. Colakoglu
    N. Ekizoglu
    U. Aykan
    BMC Ophthalmology, 18
  • [6] Efficacy of Ahmed Glaucoma Valve Implantation on Neovascular Glaucoma
    Xie, Zhan
    Liu, Hai
    Du, Mulong
    Zhu, Min
    Tighe, Sean
    Chen, Xue
    Yuan, Zhilan
    Sun, Hong
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2019, 16 (10): : 1371 - 1376
  • [7] Management of uveitic glaucoma with Ahmed glaucoma valve implantation
    Da Mata, A
    Burk, SE
    Netland, PA
    Baltatzis, S
    Christen, W
    Foster, CS
    OPHTHALMOLOGY, 1999, 106 (11) : 2168 - 2172
  • [8] Ahmed valve implantation for uveitic glaucoma in children
    Foster, C
    Kafkala, C
    Choi, JY
    Hynes, AY
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [9] Anatomic considerations in the implantation of the Ahmed glaucoma valve
    Leen, MM
    Witkop, GS
    George, DP
    ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (02) : 223 - 224
  • [10] Strabismus After Ahmed Glaucoma Valve Implantation
    Robbins, Laura
    Goseki, Toshiaki
    Law, Simon K.
    Nouri-Mahdavi, Kouros
    Caprioli, Joseph
    Coleman, Anne L.
    Giaconi, Joann A.
    Demer, Joseph L.
    Velez, Federico G.
    Pineles, Stacy L.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 222 : 1 - 5