Fricke gel-layer dosimetry in high dose-rate brachytherapy

被引:9
|
作者
Carrara, M. [3 ]
Fallai, C. [4 ]
Gambarini, G. [1 ,2 ]
Negri, A. [1 ,2 ]
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[3] Fdn IRCCS Ist Nazl Tumori, Med Phys Unit, I-20133 Milan, Italy
[4] Fdn IRCCS Ist Nazl Tumori, Radiotherapy Unit, I-20133 Milan, Italy
关键词
Brachytherapy; Fricke gel; Dosimetry; POLYMER GELS; IR-192; VERIFICATION;
D O I
10.1016/j.apradiso.2009.09.036
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The aim of this study was to evaluate the reliability of Fricke gel-layer dosimeters for the measurement of in-phantom dose distributions produced by a Ir-192 brachytherapy source. The doses obtained were compared to measurements performed with thermoluminescent dosimeters and treatment planning calculations. Fricke gel-layer dosimeters have proven to be a promising tool to measure three-dimensional dose distributions in high dose-rate brachytherapy. (c) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:722 / 725
页数:4
相关论文
共 50 条
  • [1] FRICKE GEL LAYER DOSIMETRY FOR IN-PHANTOM ABSOLUTE DOSE MEASUREMENTS IN HDR BRACHYTHERAPY
    Gambarini, G.
    Carrara, M.
    Gambini, I.
    Tomatis, S.
    Negri, A.
    Mariani, M.
    Fallai, C.
    Olmi, P.
    Zonca, G.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S104 - S105
  • [2] DOSE DETERMINATION IN HIGH DOSE-RATE BRACHYTHERAPY
    HOUDEK, PV
    SCHWADE, JG
    WU, XD
    PISCIOTTA, V
    FIEDLER, JA
    SERAGO, CF
    MARKOE, AM
    ABITBOL, AA
    LEWIN, AA
    BRAUNSCHWEIGER, PG
    SKLAR, MD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (04): : 795 - 801
  • [3] In vivo dosimetry with an inorganic scintillation detector during multi-channel vaginal cylinder pulsed dose-rate brachytherapy: Dosimetry for pulsed dose-rate brachytherapy
    Georgi, Peter D.
    Hansen, Anders T.
    Spejlborg, Harald
    Rylander, Susanne
    Lindegaard, Jacob
    Buus, Simon
    Wulff, Christian
    Petric, Primoz
    Tanderup, Kari
    Johansen, Jacob G.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [4] High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer
    Ghadjar, Pirus
    Bojaxhiu, Beat
    Simcock, Mathew
    Terribilini, Dario
    Isaak, Bernhard
    Gut, Philipp
    Wolfensberger, Patrick
    Broemme, Jens O.
    Geretschlaeger, Andreas
    Behrensmeier, Frank
    Pica, Alessia
    Aebersold, Daniel M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (04): : 1205 - 1212
  • [5] Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
    Daskalov, GM
    Loffler, E
    Williamson, JF
    MEDICAL PHYSICS, 1998, 25 (11) : 2200 - 2208
  • [6] Gel-layer dosimetry for dose verification in intensity-modulated radiation therapy
    Tomatis, S.
    Carrara, M.
    Gambarini, G.
    Marchesini, R.
    Valente, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 506 - 509
  • [7] HIGH DOSE-RATE BRACHYTHERAPY - THE RADIOGRAPHERS ROLE
    SARGEANT, SE
    JENNER, GE
    BRACHYTHERAPY 2, 1989, : 491 - 493
  • [8] New frontiers in high dose-rate brachytherapy
    Thomadsen, B
    Kolkman-Deurloo, IK
    Goodin, F
    Kuske, R
    GENERAL PRACTICE OF RADIATION ONCOLOGY PHYSICS IN THE 21ST CENTURY, 2000, (26): : 293 - 325
  • [9] TREATMENT OF LIP CANCER USING HIGH DOSE-RATE OR LOW DOSE-RATE BRACHYTHERAPY
    Bojaxhiu, B.
    Ghadjar, P.
    Simcock, M.
    Terribilini, D.
    Behrensmeier, F.
    Gut, P.
    Wolfensberger, P.
    Pica, A.
    Geretschlaeger, A.
    Aebersold, D. M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 518 - 518
  • [10] RSC: Dosimetry in high-dose-rate brachytherapy with a radiofluorogenic gel dosimeter
    Inoue, K.
    Watanabe, Y.
    Maeyama, T.
    Mizukami, S.
    Hayashi, S.
    Terazaki, T.
    Muraishi, H.
    Gomi, T.
    Shimono, T.
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167