Gel-layer dosimetry for dose verification in intensity-modulated radiation therapy

被引:11
|
作者
Tomatis, S.
Carrara, M.
Gambarini, G.
Marchesini, R.
Valente, M.
机构
[1] Inst Nazl Tumori, I-20133 Milan, Italy
[2] Univ Milan, Dept Phys, I-20133 Milan, Italy
[3] Natl Inst Nucl Phys, INFN, I-20133 Milan, Italy
关键词
gel layer dosimetry; semiconductor array detectors; IMRT dose verification; treatment planning system; dose comparison;
D O I
10.1016/j.nima.2007.05.216
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Intensity-modulated radiotherapy (IMRT) is a technique in which the radiation fluence within each of the treatment beams is not uniformly distributed. This allows the patient dose to follow the boundaries even of a target volume of complex shape, and, virtually, to spare critical healthy organs at risk. The agreement between planned and delivered IMRT dose is verified by means of standard dosimetric methods such as film dosimetry or semiconductors array dosimetry. In this paper, we compare the output of a commercial device using an array of diodes for IMRT absolute dose verification with the output of a gel dosimeter, composed by a 10 x 8cm(2) rectangular layer of a tissue-equivalent gel matrix in which a proper chemical dosimeter has been incorporated. The dose distribution is derived from the images of visible light transmittance, detected with a CCD camera before and after the gel exposure. The analysis was carried out on a single IMRT field chosen among those archived at the Istituto Nazionale Tumori of Milan. The radiation field was examined in an area common to both dosimeters. The agreement between the two detectors was good, as shown by analysis of dose profiles, especially for doses above 15-20cGy. Gel dosimeter was in good agreement with the planned dose too, with a percentage of dosimeter points passing a dose to agreement test ranging between 90% and 93%. Although preliminary, our data suggest that gel dosimetry is a reliable method for IMRT dose verification. Due to the good spatial resolution and to the tissue equivalent properties of its composition, it would be suitable also for 3D IMRT dose reconstruction and verification in the form of multiple piled-up gel layers. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:506 / 509
页数:4
相关论文
共 50 条
  • [1] Relative profile and dose verification of intensity-modulated radiation therapy
    Chang, JW
    Mageras, GS
    Chui, CS
    Ling, CC
    Lutz, W
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (01): : 231 - 240
  • [2] Validation and application of polymer gel dosimetry for the dose verification of an intensity-modulated arc therapy (IMAT) treatment
    Vergote, K
    De Deene, Y
    Duthoy, W
    De Gersem, W
    De Neve, W
    Achten, E
    De Wagter, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02): : 287 - 305
  • [3] MAGIC-type polymer gel for three-dimensional dosimetry:: Intensity-modulated radiation therapy verification
    Gustavsson, H
    Karlsson, A
    Bäck, SÅJ
    Olsson, LE
    Haraldsson, P
    Engström, P
    Nyström, H
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1264 - 1271
  • [4] Verification system for intensity-modulated radiation therapy with scintillator
    Ando, Yasuharu
    Miki, Kentaro
    Araki, Jun
    Tsuneda, Masato
    Kiriu, Hiroshi
    Nishio, Teiji
    Nagata, Yasushi
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (01) : 9 - 21
  • [5] In vivo dosimetric verification of intensity-modulated radiation therapy
    Chytyk-Praznik, K.
    Van Uytven, E.
    Van Beek, T.
    McCurdy, B. M. C.
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4629 - 4629
  • [6] Verification system for intensity-modulated radiation therapy with scintillator
    Yasuharu Ando
    Kentaro Miki
    Jun Araki
    Masato Tsuneda
    Hiroshi Kiriu
    Teiji Nishio
    Yasushi Nagata
    [J]. Physical and Engineering Sciences in Medicine, 2021, 44 : 9 - 21
  • [7] Intensity-modulated radiation therapy dose verification using fluence and portal imaging device
    Sumida, Iori
    Yamaguchi, Hajime
    Das, Indra J.
    Kizaki, Hisao
    Aboshi, Keiko
    Tsujii, Mari
    Yamada, Yuji
    Suzuki, Osamu
    Seo, Yuji
    Isohashi, Fumiaki
    Ogawa, Kazuhiko
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 259 - 271
  • [8] Absolute film dosimetry for verification in intensity modulated radiation therapy
    Mercay, A
    Moeckli, R
    Pache, G
    Bulling, S
    Do, HP
    Bressan, S
    Valley, JF
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 108 - 108
  • [9] Monte Carlo dose verification for intensity-modulated arc therapy
    Li, XA
    Ma, LJ
    Naqvi, S
    Shih, RP
    Yu, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09): : 2269 - 2282
  • [10] Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions
    Vergote, K
    De Deene, Y
    Claus, F
    De Gersem, W
    Van Duyse, B
    Paelinck, L
    Achten, E
    De Neve, W
    De Wager, C
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 67 (01) : 119 - 128