Gel-layer dosimetry for dose verification in intensity-modulated radiation therapy

被引:11
|
作者
Tomatis, S.
Carrara, M.
Gambarini, G.
Marchesini, R.
Valente, M.
机构
[1] Inst Nazl Tumori, I-20133 Milan, Italy
[2] Univ Milan, Dept Phys, I-20133 Milan, Italy
[3] Natl Inst Nucl Phys, INFN, I-20133 Milan, Italy
关键词
gel layer dosimetry; semiconductor array detectors; IMRT dose verification; treatment planning system; dose comparison;
D O I
10.1016/j.nima.2007.05.216
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Intensity-modulated radiotherapy (IMRT) is a technique in which the radiation fluence within each of the treatment beams is not uniformly distributed. This allows the patient dose to follow the boundaries even of a target volume of complex shape, and, virtually, to spare critical healthy organs at risk. The agreement between planned and delivered IMRT dose is verified by means of standard dosimetric methods such as film dosimetry or semiconductors array dosimetry. In this paper, we compare the output of a commercial device using an array of diodes for IMRT absolute dose verification with the output of a gel dosimeter, composed by a 10 x 8cm(2) rectangular layer of a tissue-equivalent gel matrix in which a proper chemical dosimeter has been incorporated. The dose distribution is derived from the images of visible light transmittance, detected with a CCD camera before and after the gel exposure. The analysis was carried out on a single IMRT field chosen among those archived at the Istituto Nazionale Tumori of Milan. The radiation field was examined in an area common to both dosimeters. The agreement between the two detectors was good, as shown by analysis of dose profiles, especially for doses above 15-20cGy. Gel dosimeter was in good agreement with the planned dose too, with a percentage of dosimeter points passing a dose to agreement test ranging between 90% and 93%. Although preliminary, our data suggest that gel dosimetry is a reliable method for IMRT dose verification. Due to the good spatial resolution and to the tissue equivalent properties of its composition, it would be suitable also for 3D IMRT dose reconstruction and verification in the form of multiple piled-up gel layers. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:506 / 509
页数:4
相关论文
共 50 条
  • [31] Dosimetry reproducibility of Intensity-Modulated Radiation Therapy using a commercially available system
    Zheng, Z
    Cardarelli, G
    Shearer, D
    Wazer, D
    DiPetrillo, T
    Chougule, P
    Puthawala, Y
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1263 - 1263
  • [32] Uncertainty estimation in intensity-modulated radiotherapy absolute dosimetry verification
    Sanchez-Doblado, Francisco
    Hartmann, Gunther H.
    Pena, Javier
    Capote, Roberto
    Paiusco, Marta
    Rhein, Bernhard
    Leal, Antonio
    Lagares, Juan Ignacio
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01): : 301 - 310
  • [33] Commentary - Intensity-modulated radiation therapy
    Goffman, TE
    Glatstein, E
    [J]. RADIATION RESEARCH, 2002, 158 (01) : 115 - 117
  • [34] Intensity-Modulated Radiation Therapy - Foreword
    Johnstone, PAS
    [J]. CURRENT PROBLEMS IN CANCER, 2004, 28 (02) : 46 - 46
  • [35] A review of intensity-modulated radiation therapy
    Laurie E. Gaspar
    Meisong Ding
    [J]. Current Oncology Reports, 2008, 10 : 294 - 299
  • [36] The physics of intensity-modulated radiation therapy
    Boyer, AL
    [J]. PHYSICS TODAY, 2002, 55 (09) : 38 - 44
  • [37] A Review of Intensity-Modulated Radiation Therapy
    Gaspar, Laurie E.
    Ding, Meisong
    [J]. CURRENT ONCOLOGY REPORTS, 2008, 10 (04) : 294 - 299
  • [38] ICRU reference dose in an era of intensity-modulated radiation therapy clinical trials: Correlation with planning target volume mean dose and suitability for intensity-modulated radiation therapy dose prescription
    Yaparpalvi, Ravindra
    Hong, Linda
    Mah, Dennis
    Shen, Jin
    Mutyala, Subhakar
    Spierer, Marnee
    Garg, Madhur
    Guha, Chandan
    Kalnicki, Shalom
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 89 (03) : 347 - 352
  • [39] Clinically relevant standards for intensity-modulated radiation therapy dose prescription
    Willins, John
    Kachnic, Lisa
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2008, 100 (05) : 288 - U4
  • [40] The impact of Monte Carlo dose calculations on intensity-modulated radiation therapy
    Siebers, JV
    Keall, PJ
    Mohan, R
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 205 - 210