Fricke gel-layer dosimetry in high dose-rate brachytherapy

被引:9
|
作者
Carrara, M. [3 ]
Fallai, C. [4 ]
Gambarini, G. [1 ,2 ]
Negri, A. [1 ,2 ]
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[3] Fdn IRCCS Ist Nazl Tumori, Med Phys Unit, I-20133 Milan, Italy
[4] Fdn IRCCS Ist Nazl Tumori, Radiotherapy Unit, I-20133 Milan, Italy
关键词
Brachytherapy; Fricke gel; Dosimetry; POLYMER GELS; IR-192; VERIFICATION;
D O I
10.1016/j.apradiso.2009.09.036
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The aim of this study was to evaluate the reliability of Fricke gel-layer dosimeters for the measurement of in-phantom dose distributions produced by a Ir-192 brachytherapy source. The doses obtained were compared to measurements performed with thermoluminescent dosimeters and treatment planning calculations. Fricke gel-layer dosimeters have proven to be a promising tool to measure three-dimensional dose distributions in high dose-rate brachytherapy. (c) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:722 / 725
页数:4
相关论文
共 50 条
  • [41] High dose-rate endoluminal brachytherapy for primary and recurrent esophageal cancer
    Nicolay, Nils H.
    Rademacher, Johanna
    Oelmann-Avendano, Jan
    Debus, Juergen
    Huber, Peter E.
    Lindel, Katja
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (07) : 458 - 466
  • [42] A mathematical optimization model for spatial adjustments of dose distributions in high dose-rate brachytherapy
    Moren, Bjorn
    Larsson, Torbjorn
    Tedgren, Asa Carlsson
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (22):
  • [43] Single dose high dose-rate (HDR) brachytherapy as monotherapy for localised prostate cancer
    Tharmalingam, H.
    Tsang, Y. M.
    Hoskin, P.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S337 - S337
  • [44] A dosimetric comparison of high dose rate (HDR) and low dose-rate (LDR) prostate brachytherapy.
    Al-Hebshi, A
    Morton, G
    Sankreacha, R
    RADIOTHERAPY AND ONCOLOGY, 2004, 72 : S36 - S36
  • [45] Dose Distribution of High Dose-Rate and Low Dose-Rate Prostate Brachytherapy at Different Intervals-Impact of a Hydrogel Spacer and Prostate Volume
    Haddad, Hathal
    Hermani, Horst
    Hanitzsch, Herbert
    Heidrich, Albert
    Pinkawa, Michael
    CANCERS, 2023, 15 (05)
  • [46] High dose rate brachytherapy three-dimensional gel dosimetry using optical computed tomography readout
    DeVries, D. A.
    Joshi, C.
    Schreiner, L. J.
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [47] Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source (vol 25, pg 2200, 1998)
    Daskalov, G
    MEDICAL PHYSICS, 2000, 27 (08) : 1999 - 1999
  • [48] RATE OF COMPLICATIONS AND DOSE-RATE IN BRACHYTHERAPY FOR CARCINOMA OF THE UTERINE CERVIX
    JANIK, I
    BUNEMANN, H
    STRAHLENTHERAPIE, 1980, 156 (07) : 457 - 465
  • [49] Prospects for quantitative two-dimensional radiochromic film dosimetry for low dose-rate brachytherapy sources
    Le, Yi
    Ali, Imad
    Dempsey, James F.
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2006, 33 (12) : 4622 - 4634
  • [50] Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy
    Andersen, Claus E.
    Nielsen, Soren Kynde
    Lindegaard, Jacob Christian
    Tanderup, Kari
    MEDICAL PHYSICS, 2009, 36 (11) : 5033 - 5043