Fracture of the subcutaneous patch electrode in a patient with an implanted cardioverter-defibrillator

被引:1
|
作者
Milasinovic, G [1 ]
Jelic, V [1 ]
Savic, D [1 ]
Pavlovic, SU [1 ]
Velinovic, M [1 ]
机构
[1] Clin Ctr Serbia, Inst Cardiovasc Dis, Pacemaker Ctr, YU-11000 Belgrade, Serbia Monteneg, Serbia
关键词
cardioverter-defibrillators; patch electrode; tetralogy of Fallot;
D O I
10.1253/circj.69.116
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There are more than 20 years of experience with implantation of defibrillator devices in humans and the procedure is an important therapeutic option for patients at high risk of life-threatening ventricular arrhythmias. The incidence of new defibrillator implantation has gradually increased, being used even in children,(1) although pediatric use is associated with several complications, especially with epicardial systems,(2) including fracture of the subcutaneous patch,(3-5) mainly because of growths We present a case of subcutaneous patch electrode fracture in the left axillary pectoral region of a patient who needed the patch for effective defibrillation, and we discuss the methods of treatment.
引用
收藏
页码:116 / 118
页数:3
相关论文
共 50 条
  • [31] Inappropriate Shocks With Subcutaneous Implantable Cardioverter-Defibrillator in a Young Patient: A Case Report
    Khan, Zahid
    Sethumadhavan, Dinesh
    Rayner, Tom
    Kyaw, Sithu
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [32] Inappropriate Shock Due to Myopotential Oversensing in a Patient With Subcutaneous Implantable Cardioverter-Defibrillator
    Alasti, Mohammad
    Machado, Colin
    Kotschet, Emily
    Alison, Jeff
    HEART LUNG AND CIRCULATION, 2019, 28 (04): : E88 - E90
  • [33] The implantable cardioverter-defibrillator - Patient perspective
    Reiffel, JA
    Dizon, J
    CIRCULATION, 2002, 105 (09) : 1022 - 1024
  • [34] Acute human defibrillation performance of a subcutaneous implantable cardioverter-defibrillator with an additional coil electrode
    Yap, Sing -Chien
    Oosterwerff, Erik F. J.
    Boersma, Lucas V. A.
    van der Stuijt, Willeke
    Lenssen, Anneke
    Hahn, Stephen J.
    Knops, Reinoud E.
    HEART RHYTHM, 2023, 20 (12) : 1649 - 1656
  • [35] Coping styles in patients with an implanted cardioverter-defibrillator (ICD)
    Fritzsche, K
    Mundschenk, A
    Scheib, P
    Herrmann, C
    Bergmann, G
    Drinkmann, A
    Dumm, A
    Kanwischer, H
    Smeritschnig, B
    Stix, P
    PSYCHOSOMATIC MEDICINE, 1999, 61 (01): : 114 - 114
  • [36] Alternans of the Ventricular Electrogram in Patients with an Implanted Cardioverter-Defibrillator
    Barold, S. Serge
    Kucher, Andreas
    de Meester, Antoine
    Stroobandt, Roland X.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (12): : 1470 - 1480
  • [37] A subcutaneous implantable cardioverter-defibrillator - the first implantation in Poland
    Kaczmarek, Krzysztof
    Zwolinski, Radoslaw
    Bartczak, Karol
    Ptaszynski, Pawel
    Wranicz, Jerzy Krzysztof
    Kardiologia Polska, 2015, 73 (01) : 62 - 62
  • [38] Subcutaneous implantable cardioverter-defibrillator (S-ICD)
    Lobodzinski, S. Suave
    CARDIOLOGY JOURNAL, 2011, 18 (03) : 326 - 331
  • [39] The Subcutaneous Implantable Cardioverter-Defibrillator When Less Is More
    Curtis, Anne B.
    Beck, Hiroko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (16) : 1616 - 1618
  • [40] Postapproval Study of a Subcutaneous Implantable Cardioverter-Defibrillator System
    Gold, Michael R.
    El-Chami, Mikhael F.
    Burke, Martin C.
    Upadhyay, Gaurav A.
    Niebauer, Mark J.
    Prutkin, Jordan M.
    Herre, John M.
    Kutalek, Steven
    Dinerman, Jay L.
    Knight, Bradley P.
    Leigh, Jill
    Lucas, Lindsay
    Carter, Nathan
    Brisben, Amy J.
    Aasbo, Johan D.
    Weiss, Raul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (05) : 383 - 397