Alternans of the Ventricular Electrogram in Patients with an Implanted Cardioverter-Defibrillator

被引:1
|
作者
Barold, S. Serge [1 ]
Kucher, Andreas [2 ]
de Meester, Antoine [3 ]
Stroobandt, Roland X. [4 ]
机构
[1] Univ Rochester, Sch Med & Dent, Dept Med, Rochester, NY 14642 USA
[2] Biotronik, Berlin, Germany
[3] Jolimont Hosp, Dept Cardiol, Haine St Paul, Belgium
[4] Ghent Univ Hosp, Ctr Heart, B-9000 Ghent, Belgium
来源
关键词
electrical alternans; ventricular tachycardia; bidirectional ventricular tachycardia; implantable cardioverter-defibrillator; catecholaminergic polymorphic ventricular tachycardia; cycle length alternans; QRS ALTERNANS; ELECTRICAL ALTERNANS; CARDIAC ALTERNANS; TACHYCARDIA; MECHANISM; ICD;
D O I
10.1111/pace.12758
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The occurrence and significance of alternans of the ventricular electrogram (VEGM) in patients with an implanted cardioverter-defibrillator (ICD) has been rarely reported. Objectives and Methods: This report describes our observations of VEGM alternans documented in nine patients with an ICD (seven new cases and two previously published cases for comparison). Results: We found seven new cases of near-field VEGM alternans and added two of our previously reported examples. Catecholaminergic polymorphic ventricular tachycardia (CPVT) was diagnosed in one patient based on ICD recordings. Alternans occurred during ventricular tachycardia (VT) in eight patients. A fast sinus tachycardia could not be ruled out in one patient. Stable cycle length alternans was found in five patients. QRS alternans of the left ventricular (LV) electrogram (EGM) was recorded in all five patients who had a device for cardiac resynchronization therapy capable of sensing by the LV channel. These five cases exhibited corresponding alternans of the right ventricular (RV) EGM in three cases, none in one patient, and a questionable recording in another. Alternans of the far-field (FF) VEGM occurred simultaneously with RV EGM alternans in all four patients whose device provided an FF tracing. Conclusion: Ventricular alternans may be more common than realized in ICD patients with VT. The correlation of VEGM alternans with the surface electrocardiogram remains unknown. Although QRS alternans itself as an electrical pattern is generally benign, its cause may not be, as illustrated in our patient with CPVT. Furthermore, associated cycle length alternans or undersensing of the smaller alternans component may complicate ICD therapy.
引用
收藏
页码:1470 / 1480
页数:11
相关论文
共 50 条
  • [1] Various patterns of intracardiac electrogram T-wave alternans prior to ventricular tachyarrhythmias in implantable cardioverter-defibrillator patients
    Ikeda, Takanori
    Yusu, Satoru
    Yokoyama, Yasuhiro
    HEART RHYTHM, 2012, 9 (07) : 1033 - 1037
  • [2] The occupational routine of patients implanted with cardioverter-defibrillator
    Mannini, Juliana
    Nascimento, Janaina Santos
    Pelosi, Miryam Bonadiu
    CADERNOS DE TERAPIA OCUPACIONAL DA UFSCAR, 2015, 23 (01): : 31 - 42
  • [3] Fitness to drive in patients with implanted cardioverter-defibrillator
    Klein, H. H.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2012, 137 (39) : 1927 - 1930
  • [4] Ventricular tachycardia incidence and erythrocyte membranes β-adrenoreactivity in patients with implanted cardioverter-defibrillator
    Atabekov, Tariel A.
    Batalov, Roman E.
    Rebrova, Tatiana Yu
    Krivolapov, Sergey N.
    Muslimova, Elvira F.
    Khlynin, Mikhail S.
    Afanasiev, Sergey A.
    Popov, Sergey, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (04): : 452 - 460
  • [5] Microvolt T-wave alternans for the risk stratification of dangerous ventricular arrhythmias in patients with previously implanted automatic cardioverter-defibrillator
    Lewandowski, Maciej
    Kossuth, Irmina
    Zielonka, Joanna
    Wielusinski, Maciej
    Kazimierczak, Arkadiusz
    Kornacewicz-Jach, Zdzislawa
    Przybycien, Krzysztof
    Kaliszczak, Robert
    KARDIOLOGIA POLSKA, 2011, 69 (06) : 580 - 586
  • [6] Clustering of ventricular tachyarrhythmias in heart failure patients implanted with a biventricular cardioverter-defibrillator
    Lunati, M.
    Gasparini, M.
    Santini, M.
    Bocchiardo, M.
    Landolina, M.
    Sassara, M.
    Perego, G. B.
    Grammatico, A.
    EUROPEAN HEART JOURNAL, 2006, 27 : 609 - 609
  • [7] Coping styles in patients with an implanted cardioverter-defibrillator (ICD)
    Fritzsche, K
    Mundschenk, A
    Scheib, P
    Herrmann, C
    Bergmann, G
    Drinkmann, A
    Dumm, A
    Kanwischer, H
    Smeritschnig, B
    Stix, P
    PSYCHOSOMATIC MEDICINE, 1999, 61 (01): : 114 - 114
  • [8] Strategies to Reduce Recurrent Shocks Due to Ventricular Arrhythmias in Patients with an Implanted Cardioverter-Defibrillator
    Back, Steven H.
    Kowey, Peter R.
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2019, 8 (02) : 99 - 104
  • [9] Amiodarone therapy in patients implanted with cardioverter-defibrillator for life-threatening ventricular arrhythmias
    Satomi, Kazuhiro
    Kurita, Takashi
    Takatsuki, Seiji
    Yokoyama, Yasuhiro
    Chinushi, Masaomi
    Tsuboi, Naoya
    Nitta, Takashi
    Shoda, Morio
    Mitamura, Hideo
    CIRCULATION JOURNAL, 2006, 70 (08) : 977 - 984
  • [10] Ventricular asystole during atrial antitachycardia pacing by implanted cardioverter-defibrillator
    Herweg, B
    Barold, SS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (05): : 432 - 433