X-ray CCD calibration system using fluorescent lines

被引:7
|
作者
Hamaguchi, K
Maeda, Y
Matsumoto, H
Nishiuchi, M
Tomida, H
Koyama, K
Awaki, H
Tsuru, TG
机构
[1] Kyoto Univ, Fac Sci, Dept Phys, Sakyo Ku, Kyoto 6068502, Japan
[2] Penn State Univ, Dept Astron & Astrophys, Davey Lab 525, University Pk, PA 16802 USA
[3] MIT, Ctr Space Res, Cambridge, MA 02139 USA
关键词
CCD; calibration system; fluorescent X-rays; Astro-E;
D O I
10.1016/S0168-9002(00)00306-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a CCD calibration system using fluorescent X-ray lines with energies ranging from 1.49 keV (Al K alpha) to 11.2 keV (Se Ka). The absolute X-ray flux is calibrated by a gas proportional counter, while the emerging spectra are monitored by solid-state silicon detectors. In order to suppress contaminating X-rays in the fluorescence spectra, mechanical collimators were set in the X-ray beam line, high-purity targets for fluorescent lines were used, and band-pass filters were put on the X-ray beam line. As for the purity of the fluorescent X-rays, the typical purity achieved was similar to 98%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:360 / 364
页数:5
相关论文
共 50 条
  • [41] Fluorescent x-ray tomography system for atomic imaging
    Sato, Eiichi
    Hitomi, Keitaro
    Nomiya, Seiichiro
    Tanaka, Etsuro
    Kawai, Toshiaki
    Inoue, Takashi
    Ogawa, Akira
    Izumisawa, Mitsuru
    Shozushima, Masanori
    Sato, Shigehiro
    Takayama, Kazuyoshi
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS VIII, 2007, 6707
  • [42] The effect of chemical combination on K fluorescent x-ray emission lines
    Obert, L
    Bearden, JA
    PHYSICAL REVIEW, 1938, 54 (12): : 1000 - 1004
  • [43] Ground calibration of X-ray CCD camera XIS onboard ASTRO-E
    Tsuru, T
    Nishiuchi, H
    Awaki, H
    Hamaguchi, K
    Koyama, K
    Tomida, H
    Sakano, M
    BROAD BAND X-RAY SPECTRA OF COSMIC SOURCES, 2000, 25 (3-4): : 885 - 888
  • [44] X-ray sensitive CCD camera
    Krasnjuk, AA
    Stenin, VJ
    Larionov, SV
    Shilin, VA
    Utenkov, AA
    PHOTONICS FOR TRANSPORTATION, 1999, 3901 : 130 - 136
  • [45] X-ray linear array CCD
    Li, Ping
    Wang, Chao-Min
    Zhang, Kun
    Bandaoti Guangdian/Semiconductor Optoelectronics, 2002, 23 (02):
  • [46] Development of the x-ray CCD in Japan
    Tsunemi, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 541 (1-2): : 295 - 303
  • [47] Radiation damage of the X-ray CCD
    Tomida, H
    Matsumoto, H
    Ozaki, M
    Tazawa, Y
    Awaki, H
    Tsuru, T
    Koyama, K
    Tsunemi, H
    Yamamoto, K
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 250 - 259
  • [48] CCD OBSERVATIONS OF X-RAY BINARIES
    STEINLE, H
    PIETSCH, W
    GOTTWALD, M
    GRASER, U
    ASTROPHYSICS AND SPACE SCIENCE, 1987, 131 (1-2) : 687 - 687
  • [49] HIGH SPATIAL RESOLUTION X-RAY IMAGING SYSTEM WITH A CCD DETECTOR COUPLED WITH AN X-RAY MAGNIFIER.
    Sato, K.
    Hasegawa, Y.
    Kondo, K.
    Miyazaki, K.
    Amemiya, Y.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 226 - 227
  • [50] THEORETICAL CALCULATION OF FLUORESCENT X-RAY INTENSITIES IN FLUORESCENT X-RAY SPECTROCHEMICAL ANALYSIS
    SHIRAIWA, T
    FUJINO, N
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1966, 5 (10) : 886 - &