X-ray CCD calibration system using fluorescent lines

被引:7
|
作者
Hamaguchi, K
Maeda, Y
Matsumoto, H
Nishiuchi, M
Tomida, H
Koyama, K
Awaki, H
Tsuru, TG
机构
[1] Kyoto Univ, Fac Sci, Dept Phys, Sakyo Ku, Kyoto 6068502, Japan
[2] Penn State Univ, Dept Astron & Astrophys, Davey Lab 525, University Pk, PA 16802 USA
[3] MIT, Ctr Space Res, Cambridge, MA 02139 USA
关键词
CCD; calibration system; fluorescent X-rays; Astro-E;
D O I
10.1016/S0168-9002(00)00306-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a CCD calibration system using fluorescent X-ray lines with energies ranging from 1.49 keV (Al K alpha) to 11.2 keV (Se Ka). The absolute X-ray flux is calibrated by a gas proportional counter, while the emerging spectra are monitored by solid-state silicon detectors. In order to suppress contaminating X-rays in the fluorescence spectra, mechanical collimators were set in the X-ray beam line, high-purity targets for fluorescent lines were used, and band-pass filters were put on the X-ray beam line. As for the purity of the fluorescent X-rays, the typical purity achieved was similar to 98%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:360 / 364
页数:5
相关论文
共 50 条
  • [31] Geometry calibration between X-ray source and detector for tomosynthesis with a portable X-ray system
    Kohei Sato
    Takashi Ohnishi
    Masashi Sekine
    Hideaki Haneishi
    International Journal of Computer Assisted Radiology and Surgery, 2017, 12 : 707 - 717
  • [32] Calibration System for Space X-ray Astronomical Telescopes
    Shi, Yufeng
    Song, Xiaolin
    Gao, Shuang
    Sun, Shukun
    Wang, Wencong
    Song, Juan
    Hu, Huijun
    Shao, Sipei
    SPACE OPTICS, TELESCOPES, AND INSTRUMENTATION (AOPC 2019), 2019, 11341
  • [33] Calibration of a combined X-ray and laser imaging system
    Jin, Fenghua
    Jing, Hansong
    Qin, Lei
    Chen, Xin
    Tao, Yang
    OPTICS FOR NATURAL RESOURCES, AGRICULTURE, AND FOODS, 2006, 6381
  • [34] X-ray detectors and calibration system for the MAXI mission
    Torii, K
    Matsuoka, M
    Sugizaki, M
    Tomida, H
    Ueno, S
    Yuan, WM
    Kawai, N
    Mihara, T
    Yoshida, A
    Tsunemi, H
    Miyata, E
    Negoro, H
    Sakurai, I
    Shirasaki, Y
    Akutsu, D
    Hayashida, K
    Kitamoto, S
    Mori, K
    Ogata, H
    Yoshita, K
    Yamauchi, M
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 636 - 644
  • [35] Method for calibration of a spectrozonal X-ray diagnostic system
    Lelyukhin A.S.
    Kornev E.A.
    Adzhieva M.D.
    Biomedical Engineering, 2006, 40 (5) : 241 - 242
  • [36] Software system for the calibration of X-ray measuring instruments
    Gaytan-Gallardo, E.
    Tovar-Munoz, V. M.
    Cruz-Estrada, P.
    Vergara-Martinez, F. J.
    Rivero-Gutierrez, T.
    MEDICAL PHYSICS, 2006, 854 : 154 - +
  • [37] Calibration of x-ray fluorescence thyroid imaging system
    Mardirossian, G
    Matsushita, T
    Lei, K
    Clune, T
    Luo, D
    Karellas, A
    Botz, E
    Brill, AB
    PHYSICA MEDICA, 1996, 12 (02) : 83 - 92
  • [38] CALIBRATION SYSTEM FOR X-RAY GENERATORS AND TUBE FACTORS
    HEALEY, T
    DICKSON, DG
    ENG, T
    GREENWOOD, MWB
    BRITISH JOURNAL OF RADIOLOGY, 1979, 52 (613): : 44 - 50
  • [39] A structure measurement of the CCD pixel by using the X-ray beam
    Tsunemi, H
    Yoshita, K
    Kitamoto, S
    Miyata, E
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 230 - 240
  • [40] X-ray imaging using CCD based area detector
    Sinha, A
    SOLID STATE PHYSICS, VOL 41, 1998, 1999, : 71 - 74