X-ray CCD calibration system using fluorescent lines

被引:7
|
作者
Hamaguchi, K
Maeda, Y
Matsumoto, H
Nishiuchi, M
Tomida, H
Koyama, K
Awaki, H
Tsuru, TG
机构
[1] Kyoto Univ, Fac Sci, Dept Phys, Sakyo Ku, Kyoto 6068502, Japan
[2] Penn State Univ, Dept Astron & Astrophys, Davey Lab 525, University Pk, PA 16802 USA
[3] MIT, Ctr Space Res, Cambridge, MA 02139 USA
关键词
CCD; calibration system; fluorescent X-rays; Astro-E;
D O I
10.1016/S0168-9002(00)00306-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a CCD calibration system using fluorescent X-ray lines with energies ranging from 1.49 keV (Al K alpha) to 11.2 keV (Se Ka). The absolute X-ray flux is calibrated by a gas proportional counter, while the emerging spectra are monitored by solid-state silicon detectors. In order to suppress contaminating X-rays in the fluorescence spectra, mechanical collimators were set in the X-ray beam line, high-purity targets for fluorescent lines were used, and band-pass filters were put on the X-ray beam line. As for the purity of the fluorescent X-rays, the typical purity achieved was similar to 98%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:360 / 364
页数:5
相关论文
共 50 条
  • [21] Calibration of the energy response matrix for X-ray detector CCD236
    Zhu, Y. X.
    Lu, J. B.
    Li, X. B.
    Liu, X. Y.
    Cui, W. W.
    Han, D. W.
    Wang, J.
    Wang, Y. S.
    Zhao, X. F.
    Zhang, S.
    Wang, G. F.
    Chen, Y. P.
    Yu, N.
    Chen, Y.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (05)
  • [22] Performance and calibration of the X-ray CCD camera of the MAXI experiment on the ISS/JEM
    Miyata, E
    Natsukari, C
    Akutsu, D
    Ohtani, M
    Tsunemi, H
    Matsuoka, M
    Kawai, N
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 186 - 193
  • [23] X-ray CCD setup for large-area wire chamber calibration
    Platzer, K
    Duennweber, W
    Wellenstein, H
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1083 - 1085
  • [24] Ground calibration of X-ray CCD detectors with charge injection for the X-ray Imaging Spectrometer on Astro-E2
    LaMarr, B
    Bautz, M
    Kissel, S
    Prigozhin, G
    Hayashida, K
    Tsuru, T
    Matsumoto, H
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 385 - 391
  • [25] Development of X-ray CCD camera system with high readout rate using ASIC
    Nakajima, Hiroshi
    Matsuura, Daisuke
    Anabuki, Naohisa
    Miyata, Emi
    Tsunemi, Hiroshi
    Doty, John P.
    Ikeda, Hirokazu
    Katayama, Haruyoshi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01): : 78 - 82
  • [26] Development of X-ray CCD camera system with high readout rate using ASIC
    Nakajima, H.
    Matsuura, D.
    Anabuki, N.
    Miyata, E.
    Tsunemi, H.
    Doty, J. P.
    Ikeda, H.
    Katayama, H.
    SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011
  • [27] Line-scan CCD X-ray imaging system
    Northwest Institute of Nuclear Technology, Xi'an 710024, China
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2006, 26 (06): : 958 - 962
  • [28] The x-ray imaging system's requirements for CCD pixel
    Yu, Chunyu
    Kong, Lingli
    Zhang, Junju
    He, Chunjiu
    Zhang, Shengdong
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN IMAGING DETECTORS AND APPLICATIONS, 2011, 8194
  • [29] High resolution X-ray fluorescence measurements using a flat analyzer crystal and an X-ray CCD
    Hayakawa, S
    Kagoshima, Y
    Tsusaka, Y
    Matsui, J
    Hirokawa, T
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2001, 19 (04): : 615 - 621
  • [30] Geometry calibration between X-ray source and detector for tomosynthesis with a portable X-ray system
    Sato, Kohei
    Ohnishi, Takashi
    Sekine, Masashi
    Haneishi, Hideaki
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (05) : 707 - 717