X-ray CCD calibration system using fluorescent lines

被引:7
|
作者
Hamaguchi, K
Maeda, Y
Matsumoto, H
Nishiuchi, M
Tomida, H
Koyama, K
Awaki, H
Tsuru, TG
机构
[1] Kyoto Univ, Fac Sci, Dept Phys, Sakyo Ku, Kyoto 6068502, Japan
[2] Penn State Univ, Dept Astron & Astrophys, Davey Lab 525, University Pk, PA 16802 USA
[3] MIT, Ctr Space Res, Cambridge, MA 02139 USA
关键词
CCD; calibration system; fluorescent X-rays; Astro-E;
D O I
10.1016/S0168-9002(00)00306-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a CCD calibration system using fluorescent X-ray lines with energies ranging from 1.49 keV (Al K alpha) to 11.2 keV (Se Ka). The absolute X-ray flux is calibrated by a gas proportional counter, while the emerging spectra are monitored by solid-state silicon detectors. In order to suppress contaminating X-rays in the fluorescence spectra, mechanical collimators were set in the X-ray beam line, high-purity targets for fluorescent lines were used, and band-pass filters were put on the X-ray beam line. As for the purity of the fluorescent X-rays, the typical purity achieved was similar to 98%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:360 / 364
页数:5
相关论文
共 50 条
  • [1] X-ray CCD calibration for the AXAF CCD imaging spectrometer
    Bautz, M
    Pivovaroff, M
    Baganoff, F
    Isobe, T
    Jones, S
    Kissel, S
    LaMarr, B
    Manning, H
    Prigozhin, G
    Ricker, G
    Nousek, J
    Grant, C
    Nishikida, K
    Scholze, F
    Thornagel, R
    Ulm, G
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 : 210 - 224
  • [2] X-ray CCD calibration for the AXAF CCD imaging spectrometer
    Bautz, M
    Kissel, S
    Prigozhin, G
    Jones, S
    Isobe, T
    Manning, H
    Pivovaroff, M
    Ricker, G
    Woo, J
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 170 - 181
  • [3] Using tritium and x-ray tubes as x-ray calibration sources for the AXAF CCD imaging spectrometer
    Jones, SE
    Bautz, M
    Kissel, S
    Pivovaroff, M
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 158 - 169
  • [4] Intensity ratio of fluorescent X-ray lines
    Hevesy, G
    Alexander, E
    NATURE, 1932, 129 : 315 - 315
  • [5] Intensity ratio of fluorescent X-ray lines
    Robinson, HR
    NATURE, 1932, 129 : 618 - 618
  • [6] Calibration of single-photon counting X-ray CCD
    Zhang, Shuang-Gen
    Huang, Wen-Zhong
    Gu, Yu-Qiu
    Jiang, Gang
    Xiong, Yong
    Wen, Xian-Lun
    Wang, Guang-Chang
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2006, 18 (01): : 77 - 80
  • [7] Calibration of the x-ray CCD camera (XIS) for the ASTRO-E in the soft x-ray band
    Katayama, H
    Shouho, M
    Kohmura, T
    Katayama, K
    Ohta, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    Doty, J
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 721 - 728
  • [8] Determination of Calibration Characteristics of X-Ray Fluorescent Analysis of Rhenium
    Troeglazova, Anna V.
    Zlobina, Elena V.
    Sokolov, Alexander Yu.
    Zhangalieva, Anargul K.
    EURASIAN CHEMICO-TECHNOLOGICAL JOURNAL, 2011, 13 (3-4) : 247 - 251
  • [9] Development of a fast readout system of an X-ray CCD
    Department of Physics, Fac. Sci., Kyoto Univ., S., Kyoto, Japan
    不详
    Nucl Instrum Methods Phys Res Sect A, 1-2 (170-173):
  • [10] Development of a fast readout system of an X-ray CCD
    Awaki, H
    Hamaguchi, K
    Koyama, K
    Tomida, H
    Tsuru, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 170 - 173