Are patient-specific joint and inertial parameters necessary for accurate inverse dynamics analyses of gait?

被引:71
|
作者
Reinbolt, Jeffrey A.
Haftka, Raphael T.
Chmielewski, Terese L.
Fregly, Benjamin J. [1 ]
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Orthopaed & Rehabil, Gainesville, FL 32611 USA
[4] Univ Florida, Dept Phys Therapy, Gainesville, FL 32611 USA
关键词
body segment parameters; gait; inverse dynamics; joint parameters; linkage models;
D O I
10.1109/TBME.2006.889187
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Variations in joint parameter (JP) values (axis positions and orientations in body segments) and inertial parameter (IP) values (segment masses, mass centers, and moments of inertia) as well as kinematic noise alter the results of inverse dynamics analyses of gait. Three-dimensional linkage models with joint constraints have been proposed as one way to minimize the effects of noisy kinematic data. Such models can also be used to perform gait optimizations to predict post-treatment function given pre-treatment gait data. This study evaluates whether accurate patient-specific JP and IP values are needed in three-dimensional linkage models to produce accurate inverse dynamics results for gait. The study was performed in two stages. First, we used optimization analyses to evaluate whether patient-specific JP and IP values can be calibrated accurately from noisy kinematic data, and second, we used Monte Carlo analyses to evaluate how errors in JP and IP values affect inverse dynamics calculations. Both stages were performed using a dynamic, 27 degrees-of-freedom, full-body linkage model and synthetic (i.e., computer generated) gait data corresponding to a nominal experimental gait motion. In general, JP but not IP values could be found accurately from noisy kinematic data. Root-mean-square (RMS) errors were 3 degrees and 4 mm for JP values and I kg, 22 mm, and 74 500 kg * mm(2) for IP values. Furthermore, errors in JP but not IP values had a significant effect on calculated lower-extremity inverse dynamics joint torques. The worst RMS torque error averaged 4% bodyweight height (BW * H) due to JP variations but less than 0.25% (BW H) due to IP variations. These results suggest that inverse dynamics analyses of gait utilizing linkage models with joint constraints should calibrate the model's JP values to obtain accurate joint torques.
引用
收藏
页码:782 / 793
页数:12
相关论文
共 50 条
  • [1] Predicting Patient-Specific Tumor Dynamics: How Many Measurements Are Necessary?
    Harshe, Isha
    Enderling, Heiko
    Brady-Nicholls, Renee
    CANCERS, 2023, 15 (05)
  • [2] Quantification of gait parameters with inertial sensors and inverse kinematics
    Boetzel, Kai
    Olivares, Alberto
    Cunha, Joao Paulo
    Gorriz Saez, Juan Manuel
    Weiss, Robin
    Plate, Annika
    JOURNAL OF BIOMECHANICS, 2018, 72 : 207 - 214
  • [3] Patient-specific gait pattern in individuals with patellofemoral instability reduces knee joint loads
    Guggenberger, Bernhard
    Horsak, Brian
    Habersack, Andreas
    Kruse, Annika
    Smith, Colin R.
    Kainz, Hans
    Svehlik, Martin
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [4] Effects of hip joint centre mislocation on gait kinematics of children with cerebral palsy calculated using patient-specific direct and inverse kinematic models
    Kainz, Hans
    Carty, Christopher P.
    Maine, Sheanna
    Walsh, Henry P. J.
    Lloyd, David G.
    Modenese, Luca
    GAIT & POSTURE, 2017, 57 : 154 - 160
  • [5] Adjoint-based inverse analysis of windkessel parameters for patient-specific vascular models
    Ismail, Mahmoud
    Wall, Wolfgang A.
    Gee, Michael W.
    JOURNAL OF COMPUTATIONAL PHYSICS, 2013, 244 : 113 - 130
  • [6] Three dimensional patient-specific collagen architecture modulates cartilage responses in the knee joint during gait
    Rasanen, Lasse P.
    Mononen, Mika E.
    Lammentausta, Eveliina
    Nieminen, Miika T.
    Jurvelin, Jukka S.
    Korhonen, Rami K.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (11) : 1225 - 1240
  • [7] An inverse fitting strategy to determine the constrained mixture model parameters: application in patient-specific aorta
    Navarrete, Alvaro
    Utrera, Andres
    Rivera, Eugenio
    Latorre, Marcos
    Celentano, Diego J.
    Garcia-Herrera, Claudio M.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [8] Is Patient-Specific Instrumentation Accurate and Necessary for Open-Wedge High Tibial Osteotomy? A Meta-Analysis
    Pang, Ran
    Jiang, Zhaohui
    Xu, Chunlei
    Shi, Wei
    Zhang, Xinglong
    Wan, Xin
    Bahat, Daniel
    Li, Hui
    Senatov, Fedor
    Bulygina, Inna
    Wang, Hu
    Zhang, Huafeng
    Li, Zhijun
    ORTHOPAEDIC SURGERY, 2023, 15 (02) : 413 - 422
  • [9] Patient-Specific Debye Parameters for Human Blood
    Santorelli, Adam
    O'Halloran, Martin
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 238 - 242
  • [10] Design of patient-specific gait modifications for knee osteoarthritis rehabilitation
    Fregly, Benjamin J.
    Reinbolt, Jeffrey A.
    Rooney, Kelly L.
    Mitchell, Kim H.
    Chmielewski, Terese L.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (09) : 1687 - 1695