Are patient-specific joint and inertial parameters necessary for accurate inverse dynamics analyses of gait?

被引:71
|
作者
Reinbolt, Jeffrey A.
Haftka, Raphael T.
Chmielewski, Terese L.
Fregly, Benjamin J. [1 ]
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Orthopaed & Rehabil, Gainesville, FL 32611 USA
[4] Univ Florida, Dept Phys Therapy, Gainesville, FL 32611 USA
关键词
body segment parameters; gait; inverse dynamics; joint parameters; linkage models;
D O I
10.1109/TBME.2006.889187
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Variations in joint parameter (JP) values (axis positions and orientations in body segments) and inertial parameter (IP) values (segment masses, mass centers, and moments of inertia) as well as kinematic noise alter the results of inverse dynamics analyses of gait. Three-dimensional linkage models with joint constraints have been proposed as one way to minimize the effects of noisy kinematic data. Such models can also be used to perform gait optimizations to predict post-treatment function given pre-treatment gait data. This study evaluates whether accurate patient-specific JP and IP values are needed in three-dimensional linkage models to produce accurate inverse dynamics results for gait. The study was performed in two stages. First, we used optimization analyses to evaluate whether patient-specific JP and IP values can be calibrated accurately from noisy kinematic data, and second, we used Monte Carlo analyses to evaluate how errors in JP and IP values affect inverse dynamics calculations. Both stages were performed using a dynamic, 27 degrees-of-freedom, full-body linkage model and synthetic (i.e., computer generated) gait data corresponding to a nominal experimental gait motion. In general, JP but not IP values could be found accurately from noisy kinematic data. Root-mean-square (RMS) errors were 3 degrees and 4 mm for JP values and I kg, 22 mm, and 74 500 kg * mm(2) for IP values. Furthermore, errors in JP but not IP values had a significant effect on calculated lower-extremity inverse dynamics joint torques. The worst RMS torque error averaged 4% bodyweight height (BW * H) due to JP variations but less than 0.25% (BW H) due to IP variations. These results suggest that inverse dynamics analyses of gait utilizing linkage models with joint constraints should calibrate the model's JP values to obtain accurate joint torques.
引用
收藏
页码:782 / 793
页数:12
相关论文
共 50 条
  • [21] Patient-specific instrumentation for total shoulder arthroplasty: not as accurate as it would seem
    Lau, Simon C.
    Keith, Prue P. A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (01) : 90 - 95
  • [22] A Fast and Accurate GPU Based Patient-Specific RapidArc QA Package
    Graves, Y.
    Gu, X.
    Jia, X.
    Teke, T.
    Popescu, I.
    Kim, G.
    Jiang, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [23] Patient-specific Analyses Reveal Differences In Hemodynamic And Morphological Parameters Between Growing And Stable Unruptured Intracranial Aneurysms
    Chien, Aichi
    Yang Hong-Ho
    Colby, Geoffrey
    Szeder, Viktor
    Sayre, James
    Duckwiler, Gary
    Villablanca, Juan
    Salamon, Noriko
    Vinuela, Fernando
    STROKE, 2022, 53
  • [24] Anthropometric Features Based Gait Pattern Prediction Using Random Forest for Patient-Specific Gait Training
    Ren, Shixin
    Wang, Weiqun
    Hou, Zeng-Guang
    Liang, Xu
    Wang, Jiaxing
    Peng, Liang
    NEURAL INFORMATION PROCESSING (ICONIP 2018), PT IV, 2018, 11304 : 15 - 26
  • [25] Incorporating pathological gait into patient-specific finite element models of the haemophilic ankle
    Talbott, Harriet G.
    Wilkins, Richard A.
    Brockett, Claire L.
    Mengoni, Marlene
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2024, 23 (05) : 1607 - 1616
  • [26] Analysis on mutant specific gait patterns of mutant mice with inverse dynamics
    Oota, Satoshi
    Nakamura, Yoshihiko
    Obata, Yuichi
    Yoshiki, Atsushi
    NEUROSCIENCE RESEARCH, 2010, 68 : E376 - E376
  • [27] Reliability of patient-specific gait profiles with inertial measurement units during the 2-min walk test in incomplete spinal cord injury
    Willi, Romina
    Werner, Charlotte
    Demko, Laszlo
    de Bie, Rob
    Filli, Linard
    Zorner, Bjorn
    Curt, Armin
    Bolliger, Marc
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [28] The Effects of Anisotropy on the Stress Analyses of Patient-Specific Abdominal Aortic Aneurysms
    Jonathan P. Vande Geest
    David E. Schmidt
    Michael S. Sacks
    David A. Vorp
    Annals of Biomedical Engineering, 2008, 36 : 921 - 932
  • [29] CORR Insights®: Patient Activity After TKA Depends on Patient-specific Parameters
    Albright, John P.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (12) : 3941 - 3942
  • [30] The effects of anisotropy on the stress analyses of patient-specific abdominal aortic aneurysms
    Geest, Jonathan P. Vande
    Schmidt, David E.
    Sacks, Michael S.
    Vorp, David A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (06) : 921 - 932