Are patient-specific joint and inertial parameters necessary for accurate inverse dynamics analyses of gait?

被引:71
|
作者
Reinbolt, Jeffrey A.
Haftka, Raphael T.
Chmielewski, Terese L.
Fregly, Benjamin J. [1 ]
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Orthopaed & Rehabil, Gainesville, FL 32611 USA
[4] Univ Florida, Dept Phys Therapy, Gainesville, FL 32611 USA
关键词
body segment parameters; gait; inverse dynamics; joint parameters; linkage models;
D O I
10.1109/TBME.2006.889187
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Variations in joint parameter (JP) values (axis positions and orientations in body segments) and inertial parameter (IP) values (segment masses, mass centers, and moments of inertia) as well as kinematic noise alter the results of inverse dynamics analyses of gait. Three-dimensional linkage models with joint constraints have been proposed as one way to minimize the effects of noisy kinematic data. Such models can also be used to perform gait optimizations to predict post-treatment function given pre-treatment gait data. This study evaluates whether accurate patient-specific JP and IP values are needed in three-dimensional linkage models to produce accurate inverse dynamics results for gait. The study was performed in two stages. First, we used optimization analyses to evaluate whether patient-specific JP and IP values can be calibrated accurately from noisy kinematic data, and second, we used Monte Carlo analyses to evaluate how errors in JP and IP values affect inverse dynamics calculations. Both stages were performed using a dynamic, 27 degrees-of-freedom, full-body linkage model and synthetic (i.e., computer generated) gait data corresponding to a nominal experimental gait motion. In general, JP but not IP values could be found accurately from noisy kinematic data. Root-mean-square (RMS) errors were 3 degrees and 4 mm for JP values and I kg, 22 mm, and 74 500 kg * mm(2) for IP values. Furthermore, errors in JP but not IP values had a significant effect on calculated lower-extremity inverse dynamics joint torques. The worst RMS torque error averaged 4% bodyweight height (BW * H) due to JP variations but less than 0.25% (BW H) due to IP variations. These results suggest that inverse dynamics analyses of gait utilizing linkage models with joint constraints should calibrate the model's JP values to obtain accurate joint torques.
引用
收藏
页码:782 / 793
页数:12
相关论文
共 50 条
  • [31] Flow analyses in the lower airways:: Patient-specific model and boundary conditions
    De Backer, J. W.
    Vos, W. G.
    Gorle, C. D.
    Germonpre, P.
    Partoens, B.
    Wuyts, F. L.
    Parizel, P. M.
    De Backer, W.
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (07) : 872 - 879
  • [32] Effect of Patient-Specific Aorta Wall Properties on Hemodynamic Parameters
    Zakaria, Mohamad Shukri
    Abdullah, Haslina
    Nordin, Azmi
    Zaki, Syazwati Ahmad
    FDMP-FLUID DYNAMICS & MATERIALS PROCESSING, 2021, 17 (01): : 171 - 179
  • [33] Hip Motion Analysis Using Multi Phase (Virtual and Physical) Simulation of the Patient-specific Hip Joint Dynamics
    Otake, Yoshito
    Suzuki, Naoki
    Hattori, Asaki
    Miki, Hidenobu
    Yamamura, Mitsuyoshi
    Yonenobu, Kazuo
    Ochi, Takahiro
    Sugano, Nobuhiko
    MEDICINE MEETS VIRTUAL REALITY 16, 2008, 132 : 339 - 344
  • [34] Patient-specific computational fluid dynamics for hypertrophic obstructive cardiomyopathy
    Hou, Quanfei
    Wu, Wenqian
    Fang, Lingyun
    Zhang, Xin
    Sun, Chenchen
    Ji, Li
    Yang, Ming
    Lei, Ziqiao
    Gao, Fan
    Wang, Jing
    Xie, Mingxing
    Chen, Shu
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 389
  • [35] Patient-Specific Seizure Detection Using Nonlinear Dynamics and Nullclines
    Zabihi, Morteza
    Kiranyaz, Serkan
    Jantti, Ville
    Lipping, Tarmo
    Gabbouj, Moncef
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (02) : 543 - 555
  • [36] Patient-specific bicuspid valve dynamics: Overview of methods and challenges
    Chandran, Krishnan B.
    Vigmostad, Sarah C.
    JOURNAL OF BIOMECHANICS, 2013, 46 (02) : 208 - 216
  • [37] Accuracy of fit analysis of the patient-specific Groningen temporomandibular joint prosthesis
    Merema, B. J.
    Kraeima, J.
    Witjes, M. J. H.
    van Bakelen, N. B.
    Spijkervet, F. K. L.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (04) : 538 - 545
  • [38] Evaluation of contact characteristics of a patient-specific artificial dysplastic hip joint
    Mutlu, Ibrahim
    Ugur, Levent
    Celik, Talip
    Buluc, Levent
    Muezzinoglu, Umit Sefa
    Kisioglu, Yasin
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2014, 16 (02) : 111 - 120
  • [39] Patient-specific modeling of cardiovascular and respiratory dynamics during hypercapnia
    Ellwein, L. M.
    Pope, S. R.
    Xie, A.
    Batzel, J. J.
    Kelley, C. T.
    Olufsen, M. S.
    MATHEMATICAL BIOSCIENCES, 2013, 241 (01) : 56 - 74
  • [40] COMPUTATIONAL FLUID DYNAMICS - A PATIENT-SPECIFIC ASSESSMENT OF THE THORACIC AORTA
    Youssefi, Pouya
    Gomez, Alberto
    He, Taigang
    Anderson, Lisa
    Bunce, Nick
    Sharma, Rajan
    Figueroa, Alberto
    Jahangiri, Marjan
    HEART, 2016, 102 : A126 - A127