Predicting Patient-Specific Tumor Dynamics: How Many Measurements Are Necessary?

被引:9
|
作者
Harshe, Isha [1 ,2 ]
Enderling, Heiko [1 ,3 ,4 ]
Brady-Nicholls, Renee [1 ]
机构
[1] H Lee Moffitt Canc Ctr & Res Inst, Dept Integrated Math Oncol, Tampa, FL 33612 USA
[2] Univ S Florida, Dept Cell Mol & Microbiol, Tampa, FL 33620 USA
[3] H Lee Moffitt Canc Ctr & Res Inst, Dept Genitourinary Oncol, Tampa, FL 33612 USA
[4] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL 33612 USA
关键词
patient-specific; prediction; logistic growth; BREAST; GROWTH; MISTAKES; MRI;
D O I
10.3390/cancers15051368
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Accurately predicting tumor growth is an important component in effectively treating patients; unfortunately, acquiring sufficient data to correctly predict when a patient will progress on treatment often comes too late. In this study, we investigated the sufficient number of tumor volume measurements required to accurately predict logistic tumor growth. The model was calibrated to tumor volume data from 18 untreated breast cancer patients using a varying number of measurements. We found the number of data points necessary to be a function of the noise level and the acceptable error of the to-be-determined model parameters. This study will provide a metric by which clinicians can determine when sufficient data have been collected to confidently predict patient-specific growth dynamics, which will be aimed at assisting treatment decision-making. Acquiring sufficient data is imperative to accurately predict tumor growth dynamics and effectively treat patients. The aim of this study was to investigate the number of volume measurements necessary to predict breast tumor growth dynamics using the logistic growth model. The model was calibrated to tumor volume data from 18 untreated breast cancer patients using a varying number of measurements interpolated at clinically relevant timepoints with different levels of noise (0-20%). Error-to-model parameters and the data were compared to determine the sufficient number of measurements needed to accurately determine growth dynamics. We found that without noise, three tumor volume measurements are necessary and sufficient to estimate patient-specific model parameters. More measurements were required as the level of noise increased. Estimating the tumor growth dynamics was shown to depend on the tumor growth rate, clinical noise level, and acceptable error of the to-be-determined parameters. Understanding the relationship between these factors provides a metric by which clinicians can determine when sufficient data have been collected to confidently predict patient-specific tumor growth dynamics and recommend appropriate treatment options.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] How many Accelerants are necessary for Patient Care?
    Haverkamp, U.
    Fahrmer, A.
    Norkus, D.
    Prott, F. J.
    Eich, H. T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S163 - S163
  • [2] Are patient-specific joint and inertial parameters necessary for accurate inverse dynamics analyses of gait?
    Reinbolt, Jeffrey A.
    Haftka, Raphael T.
    Chmielewski, Terese L.
    Fregly, Benjamin J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (05) : 782 - 793
  • [3] A patient-specific in vivo tumor model
    Wasserman, R
    Acharya, R
    Sibata, C
    Shin, KH
    MATHEMATICAL BIOSCIENCES, 1996, 136 (02) : 111 - 140
  • [4] Precision of transpulmonary thermodilution: how many measurements are necessary?
    Gondos, Tibor
    Marjanek, Zsuzsanna
    Kisvarga, Zoltan
    Halasz, Gabor
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (06) : 508 - 512
  • [5] PREDICTING PATIENT-SPECIFIC ANTIGENS FOR MEDULLOBLASTOMA IMMUNOTHERAPY
    Dyson, Kyle
    Yang, Changlin
    Trivedi, Vrunda
    Wildes, Tyler
    Grippin, Adam
    Mitchell, Duane
    NEURO-ONCOLOGY, 2020, 22 : 115 - 115
  • [6] Mechanistic patient-specific predictive correlation of tumor drug response with microenvironment and perfusion measurements
    Pascal, Jennifer
    Bearer, Elaine L.
    Wang, Zhihui
    Koay, Eugene J.
    Curley, Steven A.
    Cristini, Vittorio
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2013, 110 (35) : 14266 - 14271
  • [7] Patient-Specific Implants for Pelvic Tumor Resections
    Doering, Kevin
    Staats, Kevin
    Puchner, Stephan
    Windhager, Reinhard
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (08):
  • [8] PATIENT SPECIFIC MEASUREMENTS FOR IMRT, IS IT REALLY NECESSARY?
    Olofsson, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S190 - S191
  • [9] HOW MANY PHOTONS ARE NECESSARY FOR FLUORESCENCE-LIFETIME MEASUREMENTS
    KOLLNER, M
    WOLFRUM, J
    CHEMICAL PHYSICS LETTERS, 1992, 200 (1-2) : 199 - 204
  • [10] How many measurements are necessary in diagnosing mild to moderate hypertension?
    Brueren, MM
    Petri, H
    vanWeel, C
    vanRee, JW
    FAMILY PRACTICE, 1997, 14 (02) : 130 - 135