Predicting Patient-Specific Tumor Dynamics: How Many Measurements Are Necessary?

被引:9
|
作者
Harshe, Isha [1 ,2 ]
Enderling, Heiko [1 ,3 ,4 ]
Brady-Nicholls, Renee [1 ]
机构
[1] H Lee Moffitt Canc Ctr & Res Inst, Dept Integrated Math Oncol, Tampa, FL 33612 USA
[2] Univ S Florida, Dept Cell Mol & Microbiol, Tampa, FL 33620 USA
[3] H Lee Moffitt Canc Ctr & Res Inst, Dept Genitourinary Oncol, Tampa, FL 33612 USA
[4] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL 33612 USA
关键词
patient-specific; prediction; logistic growth; BREAST; GROWTH; MISTAKES; MRI;
D O I
10.3390/cancers15051368
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Accurately predicting tumor growth is an important component in effectively treating patients; unfortunately, acquiring sufficient data to correctly predict when a patient will progress on treatment often comes too late. In this study, we investigated the sufficient number of tumor volume measurements required to accurately predict logistic tumor growth. The model was calibrated to tumor volume data from 18 untreated breast cancer patients using a varying number of measurements. We found the number of data points necessary to be a function of the noise level and the acceptable error of the to-be-determined model parameters. This study will provide a metric by which clinicians can determine when sufficient data have been collected to confidently predict patient-specific growth dynamics, which will be aimed at assisting treatment decision-making. Acquiring sufficient data is imperative to accurately predict tumor growth dynamics and effectively treat patients. The aim of this study was to investigate the number of volume measurements necessary to predict breast tumor growth dynamics using the logistic growth model. The model was calibrated to tumor volume data from 18 untreated breast cancer patients using a varying number of measurements interpolated at clinically relevant timepoints with different levels of noise (0-20%). Error-to-model parameters and the data were compared to determine the sufficient number of measurements needed to accurately determine growth dynamics. We found that without noise, three tumor volume measurements are necessary and sufficient to estimate patient-specific model parameters. More measurements were required as the level of noise increased. Estimating the tumor growth dynamics was shown to depend on the tumor growth rate, clinical noise level, and acceptable error of the to-be-determined parameters. Understanding the relationship between these factors provides a metric by which clinicians can determine when sufficient data have been collected to confidently predict patient-specific tumor growth dynamics and recommend appropriate treatment options.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Detection of Open Angle Glaucoma with Patient-Specific Macular Structural Measurements
    Kabbara, Sami
    Zangwill, Linda M.
    Bowd, Christopher
    Medeiros, Felipe
    Weinreb, Robert N.
    Belghith, Akram
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [42] Patient-specific online dose verification based on transmission detector measurements
    Thoelking, Johannes
    Fleckenstein, Jens
    Sekar, Yuvaraj
    Boggula, Ramesh
    Lohr, Frank
    Wenz, Frederik
    Wertz, Hansjoerg
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (02) : 351 - 356
  • [43] Patient-Specific Online Dose Verification Based On Transmission Detector Measurements
    Thoelking, J.
    Yuvaraj, S.
    Jens, F.
    Lohr, F.
    Wenz, F.
    Wertz, H.
    Wertz, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3474 - 3474
  • [44] IN-VIVO OBSTETRIC PRESSURE MEASUREMENTS FOR PATIENT-SPECIFIC EPIDURAL SIMULATOR
    Vaughan, Neil
    Dubey, Venketesh N.
    Wee, Michael Y. K.
    Isaacs, Richard
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2014, VOL 1A, 2014,
  • [45] The estimation of patient-specific cardiac diastolic functions from clinical measurements
    Xi, Jiahe
    Lamata, Pablo
    Niederer, Steven
    Land, Sander
    Shi, Wenzhe
    Zhuang, Xiahai
    Ourselin, Sebastien
    Duckett, Simon G.
    Shetty, Anoop K.
    Rinaldi, C. Aldo
    Rueckert, Daniel
    Razavi, Reza
    Smith, Nic P.
    MEDICAL IMAGE ANALYSIS, 2013, 17 (02) : 133 - 146
  • [46] Assessment of patient-specific instrumentation precision through bone resection measurements
    F. Zambianchi
    A. Colombelli
    V. Digennaro
    A. Marcovigi
    R. Mugnai
    F. Fiacchi
    D. Sandoni
    A. Belluati
    F. Catani
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2841 - 2848
  • [47] Assessment of patient-specific instrumentation precision through bone resection measurements
    Zambianchi, F.
    Colombelli, A.
    Digennaro, V.
    Marcovigi, A.
    Mugnai, R.
    Fiacchi, F.
    Sandoni, D.
    Belluati, A.
    Catani, F.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (09) : 2841 - 2848
  • [48] How the patient characteristics and the prescription can be accounted for in patient-specific predictive HD models?
    Casagrande, Giustina
    Costantino, Marialaura
    Pizzi, Marialavinia
    Ambrosini, Andrea
    Colturi, Carla
    Grosse, Philipp
    Venzin, Reto Martin
    Melfa, Gianvincenzo
    Pianca, Silvio
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39
  • [49] How the patient characteristics and the prescription can be accounted for in patient-specific predictive HD models?
    Casagrande, Giustina
    Costantino, Marialaura
    Pizzi, Marialavinia
    Ambrosini, Andrea
    Colturi, Carla
    Grosse, Philipp
    Venzin, Reto Martin
    Melfa, Gianvincenzo
    Pianca, Silvio
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 : I1270 - I1270
  • [50] Classification of patient-specific sensitivity to immunotherapies by ex vivo tumor testing
    Ceton, Lieke Johanna
    Montero, Marta Garcia
    Grillet, Fanny
    van der Meer, Dieudonne J.
    Vader, Willemijn
    van Altena, Anne
    de Kroon, Cor D.
    Ottevanger, Nelleke
    Kroep, Judith
    CANCER RESEARCH, 2023, 83 (07)