HOW MANY PHOTONS ARE NECESSARY FOR FLUORESCENCE-LIFETIME MEASUREMENTS

被引:260
|
作者
KOLLNER, M
WOLFRUM, J
机构
[1] Physikalisch-Chemisches Institut, W-6900 Heidelberg
关键词
D O I
10.1016/0009-2614(92)87068-Z
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
On planning time-correlated single photon counting experiments for fluorescence-lifetime measurements with minute samples, the question of ultimate sensitivity arises. To answer this question, we will find out how many detected photons one needs to achieve a certain accuracy in the lifetime estimate. Using-least-squares or maximum-likelihood procedures and the multinomial distribution, the accuracy of the lifetime estimation can be expressed explicitly as a function of the signal strength. This allows one to determine the required number of detected photons.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 50 条
  • [1] FLUORESCENCE-LIFETIME MEASUREMENTS IN MONODISPERSED SUSPENSIONS OF POLYSTYRENE PARTICLES
    TONG, BY
    JOHN, PK
    ZHU, YT
    LIU, YS
    WONG, SK
    WARE, WR
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1993, 10 (02) : 356 - 359
  • [2] FLUORESCENCE-LIFETIME MEASUREMENTS IN MONODISPERSED SUSPENSIONS OF POLYSTYRENE PARTICLES - COMMENT
    LAWANDY, NM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1993, 10 (11) : 2144 - 2146
  • [3] Determination of biological activity from fluorescence-lifetime measurements in Saccharomyces cerevisiae
    Rudek, F.
    Baselt, T.
    Lempe, B.
    Taudt, C.
    Hartmann, P.
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES XIII, 2015, 9328
  • [4] Hadamard-transform fluorescence-lifetime imaging
    Mizuno, Takahiko
    Iwata, Tetsuo
    OPTICS EXPRESS, 2016, 24 (08): : 8202 - 8213
  • [5] SINGLE-MOLECULE SPECTROSCOPY - FLUORESCENCE-LIFETIME MEASUREMENTS OF PENTACENE IN P-TERPHENYL
    PIROTTA, M
    GUTTLER, F
    GYGAX, H
    RENN, A
    SEPIOL, J
    WILD, UP
    CHEMICAL PHYSICS LETTERS, 1993, 208 (5-6) : 379 - 384
  • [6] Fluorescence-lifetime based sensing in tissues and other random media with measurements of photon migration
    SevickMuraca, EM
    Hutchinson, CL
    Troy, TL
    ANALYTICAL USE OF FLUORESCENT PROBES IN ONCOLOGY, 1996, 286 : 31 - 40
  • [7] Fluorescence-lifetime measurements in atmospheric-pressure flames using nanosecond-pulsed lasers
    M.W. Renfro
    Applied Physics B, 2002, 74 : 167 - 174
  • [8] Precision of transpulmonary thermodilution: how many measurements are necessary?
    Gondos, Tibor
    Marjanek, Zsuzsanna
    Kisvarga, Zoltan
    Halasz, Gabor
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (06) : 508 - 512
  • [9] Fluorescence-lifetime technologies for high-throughput screening
    French, T
    Owicki, JC
    Modlin, DN
    Deshpande, SS
    Mineyev, I
    Crawford, K
    Burton, W
    SYSTEMS AND TECHNOLOGIES FOR CLINICAL DIAGNOSTICS AND DRUG DISCOVERY, PROCEEDINGS OF, 1998, 3259 : 209 - 218
  • [10] Fluorescence-lifetime measurements in atmospheric-pressure flames using nanosecond-pulsed lasers
    Renfro, MW
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 74 (02): : 167 - 174