An optimised compact electron impact ion storage source for a time-of-flight mass spectrometer

被引:19
|
作者
Abplanalp, Dominic [1 ]
Wurz, Peter [1 ]
Huber, Liliane [1 ]
Leya, Ingo [1 ]
机构
[1] Univ Bern, Inst Phys, CH-3012 Bern, Switzerland
关键词
Electron impact ionisation; TOF-MS; Ion storage source; Electrostatic field separation; Space research; RESOLUTION; MESHES;
D O I
10.1016/j.ijms.2010.05.001
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
In the ion source of an ion trap time-of-flight (TOF)-mass spectrometer, an effective electrostatic field separation of the region of ion generation and ion acceleration, which have different electric field strengths, is necessary for optimal operation. At the same time, the electrostatic field separation has to have a high transmission for ions, permitting for a high sensitivity of the mass spectrometer. Usually, a single mesh is used for such an application. In our case of a compact yet high-performance system, the field separation requirements are too tight for using only a single mesh. We systematically performed ion-optical simulations, which showed that only a double grid configuration promises satisfying results. The modifications of the instrument, based on the simulations, increased the performance significantly by reducing the baseline and improving the storage of the ions; the dynamic range of the modified spectrometer after the improvements covered - in a 1 min record time - about six orders of magnitude. Systematic studies performed using the laboratory instrument confirm the results of the simulations. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [41] Dual ion source time-of-flight mass spectrometer for studies of ion-molecule reactions.
    Vest, RK
    Yates, BC
    Hales, DA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 385 - CHED
  • [42] Multiple-ion-beam time-of-flight mass spectrometer
    Rohrbacher, A
    Continetti, RE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (08): : 3386 - 3389
  • [43] Electronics of an ion trap with integrated time-of-flight mass spectrometer
    Schneider, Christian
    Schowalter, Steven J.
    Yu, Peter
    Hudson, Eric R.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 394 : 1 - 8
  • [44] Planar Multipole Ion Trap/Time-of-Flight Mass Spectrometer
    Lorenz, Ulrich J.
    Rizzo, Thomas R.
    ANALYTICAL CHEMISTRY, 2011, 83 (20) : 7895 - 7901
  • [45] A Hadamard transform electron ionization time-of-flight mass spectrometer
    Hudgens, Jeffrey W.
    Bergeron, Denis E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (01):
  • [46] Direct chemical analysis of solids by laser ablation in an ion storage time-of-flight mass spectrometer
    Klunder, GL
    Grant, PM
    Andresen, BD
    Russo, RE
    ANALYTICAL CHEMISTRY, 2004, 76 (05) : 1249 - 1256
  • [47] THE DESIGN AND PERFORMANCE OF AN ION-TRAP STORAGE REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    CHIEN, BM
    MICHAEL, SM
    LUBMAN, DM
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 131 : 149 - 179
  • [48] A MEMS electron impact ion source integrated in a microtime-of-flight mass spectrometer
    Tassetti, Charles-Marie
    Mahieu, Romain
    Danel, Jean-Sebastien
    Peyssonneaux, Olivier
    Progent, Frederic
    Polizzi, Jean-Philippe
    Machuron-Mandard, Xavier
    Duraffourg, Laurent
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 189 : 173 - 178
  • [49] REFLECTING TIME-OF-FLIGHT MASS-SPECTROMETER WITH AN ELECTROSPRAY ION-SOURCE AND ORTHOGONAL EXTRACTION
    VERENTCHIKOV, AN
    ENS, W
    STANDING, KG
    ANALYTICAL CHEMISTRY, 1994, 66 (01) : 126 - 133
  • [50] A multi-reflection time-of-flight mass spectrometer for the offline ion source of the PUMA experiment
    Schlaich, M.
    Fischer, J.
    Fischer, P.
    Klink, C.
    Obertelli, A.
    Schmidt, A.
    Schweikhard, L.
    Wienholtz, F.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2024, 495