A Hadamard transform electron ionization time-of-flight mass spectrometer

被引:5
|
作者
Hudgens, Jeffrey W. [1 ]
Bergeron, Denis E. [1 ]
机构
[1] NIST, Phys & Chem Property Div, Gaithersburg, MD 20899 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 01期
关键词
D O I
10.1063/1.2838174
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the first Hadamard transform time-of-flight mass spectrometer (HT-TOFMS) that incorporates an electron (impact) ionization source. This implementation was realized in an existent TOF instrument using commercially available components and simple modifications to the ion source. In the present apparatus, a Hadamard mask is expressed by modulating the ion generation process within the ion source; thus, the present approach differs from previous designs that use external electrostatic devices to modulate a continuous ion stream. The present implementation may be operated in conventional TOF mode at 12.5 kHz and in HT-TOF mode at 20-40 MHz. In Hadamard mode the design can operate using any circulant simplex code, allowing the operator much flexibility for optimizing resolution and mass range and for eliminating nonstochastic fluctuations, e.g., encoding errors and signal hum. We demonstrate typical performance of the HT-TOFMS in standard and reflectron geometries using sequences of three constructions and of varied length, generating HT-TOF mass spectra of molecules that match conventional reference spectra. The auxiliary material includes an electrical schematic for the floating high-speed encoding amplifier, which is also of use in other high-speed electrostatic optics applications, and a list of 537 validated vectors comprising the first row of each circulant simplex sequence (S(n)=3-8219) derived using maximal shift register (n=2(m)-1), quadratic residue (n=4m-3), and twin prime constructions [n=p(p+2)]. (c) 2008 American Institute of Physics.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Characterization of a Hadamard transform time-of-flight mass spectrometer
    Brock, A
    Rodriguez, N
    Zare, RN
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03): : 1306 - 1318
  • [2] Hadamard transform time-of-flight mass spectrometry.
    Zare, RN
    Brock, A
    Rodriguez, N
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U187 - U187
  • [3] New evidences on photoemission electron impact ionization in time-of-flight mass spectrometer
    Wang, L
    Li, HY
    Bai, JL
    Lu, RC
    [J]. INTERNET JOURNAL OF CHEMISTRY, 1998, 1 (04): : CP1 - U21
  • [4] Hyperthermal surface ionization in a time-of-flight mass spectrometer
    Weickhardt, C
    Draack, L
    Grotemeyer, J
    [J]. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2000, 6 (04) : 319 - 323
  • [5] Application of Hadamard transform to gas chromatography/nonresonant multiphoton ionization/time-of-flight mass spectrometry
    Cheng, Chao-Chiang
    Chang, Hung-Wei
    Uchimura, Tomohiro
    Imasaka, Totaro
    Kaneta, Takashi
    Lin, Cheng-Huang
    [J]. JOURNAL OF SEPARATION SCIENCE, 2010, 33 (4-5) : 626 - 630
  • [6] Electrospray ionization time-of-flight mass spectrometer for elemental analysis
    Mahoney, PP
    Guzowski, JP
    Ray, SJ
    Hieftje, GM
    [J]. APPLIED SPECTROSCOPY, 1997, 51 (10) : 1464 - 1470
  • [7] Design and performance of an electrospray ionization time-of-flight mass spectrometer
    Håkansson, K
    Zubarev, RA
    Håkansson, P
    Laiko, V
    Dodonov, AF
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (01): : 36 - 41
  • [8] Hadamard transform time-of-flight mass spectrometry:: More signal, more of the time
    Zare, RN
    Fernández, FM
    Kimmel, JR
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2003, 42 (01) : 30 - 35
  • [9] Peak height precision in Hadamard transform time-of-flight mass spectra
    Kimmel, JR
    Yoon, OK
    Zuleta, IA
    Trapp, O
    Zare, RN
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (07) : 1117 - 1130
  • [10] A TIME-OF-FLIGHT MASS SPECTROMETER
    WILSON, DB
    [J]. VACUUM, 1969, 19 (07) : 323 - &