Multiple-ion-beam time-of-flight mass spectrometer

被引:12
|
作者
Rohrbacher, A [1 ]
Continetti, RE [1 ]
机构
[1] Univ Calif San Diego, Dept Chem & Biochem, La Jolla, CA 92093 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2001年 / 72卷 / 08期
关键词
D O I
10.1063/1.1380682
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An innovative approach to increase the throughput of mass spectrometric analyses using a multiple-ion-beam mass spectrometer is described. Two sample spots were applied onto a laser desorption/ionization target and each spot was simultaneously irradiated by a beam of quadrupled Nd:YLF laser radiation (261.75 nm) to produce ions by laser-desorption ionization. Acceleration of the ions in an electric field created parallel ion beams that were focused by two parallel einzel lens systems. After a flight path of 2.34 m, the ions were detected with a microchannel plate-phosphor screen assembly coupled with a charge coupled device camera that showed two resolved ion beams. Time-of-flight mass spectra were also obtained with this detector. Experiments were performed using both metal atom cations (Ti+ and Cr+) produced by laser desorption/ionization and the molecular ions of two different proteins (myoglobin and lysozyme), created by matrix assisted laser desorption/ionization using an excess of nicotinic acid as matrix. (C) 2001 American Institute of Physics.
引用
收藏
页码:3386 / 3389
页数:4
相关论文
共 50 条
  • [1] Improvement of reflectron time-of-flight mass spectrometer for better convergence of ion beam
    Handa, Takefumi
    Horio, Takuya
    Arakawa, Masashi
    Terasaki, Akira
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 451
  • [2] CONTINUOUS ION SOURCE FOR A TIME-OF-FLIGHT MASS SPECTROMETER
    STUDIER, MH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1963, 34 (12): : 1367 - &
  • [3] BEAM COMPRESSION AND BEAM MULTIPLEXING IN A TIME-OF-FLIGHT MASS-SPECTROMETER
    RIESS, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (05): : 784 - 787
  • [4] A TIME-OF-FLIGHT MASS SPECTROMETER
    WILSON, DB
    VACUUM, 1969, 19 (07) : 323 - &
  • [5] Development of a miniature time-of-flight mass/charge spectrometer for ion beam source analyzing
    Huang, Zhengxu
    Tan, Guobin
    Zhou, Zhen
    Chen, Lei
    Cheng, Liang
    Jin, Dazhi
    Tan, Xiaohua
    Xie, Chunguang
    Li, Lei
    Dong, Junguo
    Fu, Zhong
    Cheng, Ping
    Gao, Wei
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 379 : 60 - 64
  • [6] A TIME-OF-FLIGHT MASS SPECTROMETER
    KATZENSTEIN, HS
    FRIEDLAND, SS
    PHYSICAL REVIEW, 1954, 93 (02): : 363 - 363
  • [7] A TIME-OF-FLIGHT MASS SPECTROMETER
    GOUDSMIT, SA
    PHYSICAL REVIEW, 1948, 74 (05): : 622 - 623
  • [8] A SECONDARY ION TIME-OF-FLIGHT MASS-SPECTROMETER WITH AN ION MIRROR
    TANG, X
    BEAVIS, R
    ENS, W
    LAFORTUNE, F
    SCHUELER, B
    STANDING, KG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1988, 85 (01): : 43 - 67
  • [9] Pseudorandom time-of-flight analysis with a time-of-flight mass spectrometer
    Bewig, L
    Buck, U
    Gandhi, SR
    Winter, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (02): : 417 - 422
  • [10] Electronics of an ion trap with integrated time-of-flight mass spectrometer
    Schneider, Christian
    Schowalter, Steven J.
    Yu, Peter
    Hudson, Eric R.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 394 : 1 - 8