Photography-based method for assessing fluorescein clearance test in dogs

被引:9
|
作者
Oria, Arianne Pontes [1 ]
Reboucas, Miriam Flores [1 ]
Martins Filho, Emanoel [1 ]
Dorea Neto, Francisco de Assis [1 ]
Raposo, Ana Claudia [1 ]
Sebbag, Lionel [2 ]
机构
[1] Univ Fed Bahia, Sch Vet Med & Zootechny, UFBA, Salvador, BA, Brazil
[2] Iowa State Univ, Dept Vet Clin Sci, Coll Vet Med, Ames, IA USA
来源
BMC VETERINARY RESEARCH | 2018年 / 14卷
关键词
Dogs; Fluorescein clearance test; Schirmer tear test; Tear film; TEAR TEST STRIPS; ABSORPTIVE CAPACITIES;
D O I
10.1186/s12917-018-1593-y
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: The fluorescein clearance test (FCT) provides insight into the tear film dynamics. The purpose of this study was to describe an inexpensive and practical method for assessing FCT in dogs, using photography and software analysis, and to assess the retention time of 1 vs. 2 eye drops on the canine ocular surface. Methods: (i) In vivo - Eight healthy German Shepherd dogs were recruited. Following topical anesthesia with 0.5% proxymetacaine, each eye sequentially received (1 week apart) either 1 drop (35 mu L) or 2 drops (70 mu L) of 0.5% fluorescein. A Schirmer strip was inserted in the ventral conjunctival fornix for 10 s at the following times: each 10 min for 100 min, 24 h, 48 h and 72 h. (ii) In vitro - Schirmer strips were placed for 10 s in contact with microplate wells containing 1 or 2 drops of 0.5% fluorescein. In both experiments, the fluorescein-impregnated Schirmer strips were immediately imaged, and the area and intensity of fluorescein uptake were analyzed with ImageJ software. For the in vitro experiment, images were evaluated by the same examiner (repeatability) or two examiners (reproducibility). Results: Photography-based FCT was easy to perform and showed high repeatability and reproducibility (coefficients of variation <= 2.75%). In vivo, the area and intensity of fluorescein uptake on Schirmer strips were significantly greater at 30 min and 40 min post-fluorescein instillation in the 2 drops vs. 1 drop groups (p <= 0.044). Compared to baseline, the residual fluorescein uptake on Schirmer strips was < 5% at 60 min and 90 min in the 1 drop and 2 drops groups, respectively. Conclusions: Photography-based FCT is a practical and reliable diagnostic tool with various clinical and research applications in veterinary medicine. Instillation of two drops provided greater amount and longer retention on the anesthetized canine ocular surface than a single drop. Fluorescein clearance time of a single drop in dolichocephalic dogs is 60 min.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Photography-based method for assessing fluorescein clearance test in dogs
    Arianne Pontes Oriá
    Miriam Flores Rebouças
    Emanoel Martins Filho
    Francisco de Assis Dórea Neto
    Ana Cláudia Raposo
    Lionel Sebbag
    BMC Veterinary Research, 14
  • [2] Correction to: Photography-based method for assessing fluorescein clearance test in dogs
    Arianne Pontes Oriá
    Miriam Flores Rebouças
    Emanoel Martins Filho
    Francisco de Assis Dórea Neto
    Ana Cláudia Raposo
    Lionel Sebbag
    BMC Veterinary Research, 14
  • [3] Photography-based method for assessing fluorescein clearance test in dogs (vol 14, 269, 2018)
    Oria, Arianne Pontes
    Reboucas, Miriam Flores
    Martins Filho, Emanoel
    Dorea Neto, Francisco de Assis
    Raposo, Ana Claudia
    Sebbag, Lionel
    BMC VETERINARY RESEARCH, 2018, 14
  • [4] A UAV Photography-Based Detection Method for Defective Road Marking
    Bu, Tianxiang
    Zhu, Junqing
    Ma, Tao
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2022, 36 (05)
  • [5] Grading conjunctival hyperemia using a photography-based method.
    Twelker, JD
    Bailey, IL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S927 - S927
  • [6] Objectifying the Conjunctival Provocation Test: Photography-Based Rating and Digital Analysis
    Dogan, S.
    Astvatsatourov, A.
    Deserno, T. M.
    Bock, F.
    Shah-Hosseini, K.
    Michels, A.
    Moesges, R.
    INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY, 2014, 163 (01) : 59 - 68
  • [7] Validation of a photography-based goniometry method for measuring joint range of motion
    Blonna, Davide
    Zarkadas, Peter C.
    Fitzsimmons, James S.
    O'Driscoll, Shawn W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (01) : 29 - 35
  • [8] Effects of Photography-Based Public Art on the School Environment
    Ozga, Kasia A.
    STUDIES IN ART EDUCATION, 2016, 57 (03) : 203 - 220
  • [9] AN IMPROVED METHOD FOR FLUORESCEIN DYE PHOTOGRAPHY
    EROL, OO
    SPIRA, M
    JUSTICE, J
    PARSA, FD
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1981, 68 (01) : 120 - 121
  • [10] Developing a More Reliable Aerial Photography-Based Method for Acquiring Freeway Traffic Data
    Zhang, Chi
    Tang, Zhongze
    Zhang, Min
    Wang, Bo
    Hou, Lei
    REMOTE SENSING, 2022, 14 (09)