Objectifying the Conjunctival Provocation Test: Photography-Based Rating and Digital Analysis

被引:17
|
作者
Dogan, S. [1 ]
Astvatsatourov, A. [1 ]
Deserno, T. M. [3 ]
Bock, F. [2 ]
Shah-Hosseini, K. [1 ]
Michels, A. [1 ]
Moesges, R. [1 ]
机构
[1] Univ Hosp Cologne, Inst Med Stat Informat & Epidemiol, DE-50931 Cologne, Germany
[2] Univ Hosp Cologne, Dept Ophthalmol, DE-50931 Cologne, Germany
[3] Rhein Westfal TH Aachen, Univ Hosp, Dept Med Informat, Aachen, Germany
关键词
Conjunctival provocation test; Digital image analysis; Photography-based rating; Nasal provocation tests; Pollen allergens; Allergic rhinoconjunctivitis; ALLERGEN CHALLENGE; IMAGE-ANALYSIS; UPPER AIRWAYS; SKIN PRICK; QUANTIFICATION; GUIDELINES; HISTAMINE; RHINITIS; RHINOCONJUNCTIVITIS; SENSITIVITY;
D O I
10.1159/000355333
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Patients with allergic rhinoconjunctivitis are susceptible to both nasal and ocular symptoms. The conjunctival provocation test (CPT) is an established diagnostic procedure used in allergic rhinoconjunctivitis, particularly to document a patient's current reactivity to allergens. To date, there are no international guidelines defining the CPT. No approved evaluation method exists for interpreting CPT results. This paper aims to establish the digital analysis of macroimages as an objective, validated and standardized method for interpreting CPT results. Methods: In a clinical immunotherapy trial with 155 patients, treatment progress was documented based on the CPT. Local investigators used a symptom score to grade tearing, reddening and the patients' subjective perception of symptoms (mucosal irritation). A central observer rated conjunctival hyperemia via digital photography. Digital image analysis software was utilized to determine conjunctival hyperemia. Results: Spearman's correlation between the local investigators' and the central observer's ratings was r = 0.729 (p < 0.001); the percentage of total agreement was 48% (based on 739 photos). Digital image analysis (based on 48 photos) had a high percentage of total agreement with the central observer's ratings (69%) but a low percentage of total agreement with the investigators' ratings (38%). The corresponding correlations were r = 0.264 and 0.064, respectively. Conclusion: Photography-based rating by a central observer may represent a valuable supplement to the local investigator's assessment for making an objective evaluation of CPT results. Digital image analysis possesses the potential of being an objective evaluation method compared to the wide-spread subjective evaluation by the investigators. (C) 2013 S. Karger AG, Basel
引用
收藏
页码:59 / 68
页数:10
相关论文
共 46 条
  • [1] Objectifying the conjunctival provocation test - photography- based rating and digital analysis
    Dogan, S.
    Astvatsatourov, A.
    Deserno, T. M.
    Bock, F.
    Shah-Hosseini, K.
    Moesges, R.
    ALLERGY, 2013, 68 : 131 - 131
  • [2] Grading conjunctival hyperemia using a photography-based method.
    Twelker, JD
    Bailey, IL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S927 - S927
  • [3] Photography-based method for assessing fluorescein clearance test in dogs
    Oria, Arianne Pontes
    Reboucas, Miriam Flores
    Martins Filho, Emanoel
    Dorea Neto, Francisco de Assis
    Raposo, Ana Claudia
    Sebbag, Lionel
    BMC VETERINARY RESEARCH, 2018, 14
  • [4] Photography-based method for assessing fluorescein clearance test in dogs
    Arianne Pontes Oriá
    Miriam Flores Rebouças
    Emanoel Martins Filho
    Francisco de Assis Dórea Neto
    Ana Cláudia Raposo
    Lionel Sebbag
    BMC Veterinary Research, 14
  • [5] Correction to: Photography-based method for assessing fluorescein clearance test in dogs
    Arianne Pontes Oriá
    Miriam Flores Rebouças
    Emanoel Martins Filho
    Francisco de Assis Dórea Neto
    Ana Cláudia Raposo
    Lionel Sebbag
    BMC Veterinary Research, 14
  • [6] Developing a digital photography-based method for dietary analysis in self-serve dining settings
    Christoph, Mary J.
    Loman, Brett R.
    Ellison, Brenna
    APPETITE, 2017, 114 : 217 - 225
  • [7] Imaging-based airborne allergy diagnosis with conjunctival provocation test
    Astvatsatourov, A.
    Zadoyan, G.
    Moesges, R.
    ALLERGY, 2014, 69 : 89 - 89
  • [8] Photography-based method for assessing fluorescein clearance test in dogs (vol 14, 269, 2018)
    Oria, Arianne Pontes
    Reboucas, Miriam Flores
    Martins Filho, Emanoel
    Dorea Neto, Francisco de Assis
    Raposo, Ana Claudia
    Sebbag, Lionel
    BMC VETERINARY RESEARCH, 2018, 14
  • [9] "allergoeye" fully automatic quantitative conjunctival provocation test based on artificial intelligence
    Yarin, Y.
    Kalaidzidis, Y.
    Kalaidzidou, A.
    ALLERGY, 2021, 76 : 430 - 430
  • [10] Retrospective Analysis of Increment Instillation of Allergen During the Conjunctival Allergen Provocation Test (CAPT)
    Lorentz, Holly Irene
    Nelson, Victoria
    Tenorio, Nerizsa
    Salapatek, Anne Marie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)