Photography-based method for assessing fluorescein clearance test in dogs

被引:9
|
作者
Oria, Arianne Pontes [1 ]
Reboucas, Miriam Flores [1 ]
Martins Filho, Emanoel [1 ]
Dorea Neto, Francisco de Assis [1 ]
Raposo, Ana Claudia [1 ]
Sebbag, Lionel [2 ]
机构
[1] Univ Fed Bahia, Sch Vet Med & Zootechny, UFBA, Salvador, BA, Brazil
[2] Iowa State Univ, Dept Vet Clin Sci, Coll Vet Med, Ames, IA USA
来源
BMC VETERINARY RESEARCH | 2018年 / 14卷
关键词
Dogs; Fluorescein clearance test; Schirmer tear test; Tear film; TEAR TEST STRIPS; ABSORPTIVE CAPACITIES;
D O I
10.1186/s12917-018-1593-y
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: The fluorescein clearance test (FCT) provides insight into the tear film dynamics. The purpose of this study was to describe an inexpensive and practical method for assessing FCT in dogs, using photography and software analysis, and to assess the retention time of 1 vs. 2 eye drops on the canine ocular surface. Methods: (i) In vivo - Eight healthy German Shepherd dogs were recruited. Following topical anesthesia with 0.5% proxymetacaine, each eye sequentially received (1 week apart) either 1 drop (35 mu L) or 2 drops (70 mu L) of 0.5% fluorescein. A Schirmer strip was inserted in the ventral conjunctival fornix for 10 s at the following times: each 10 min for 100 min, 24 h, 48 h and 72 h. (ii) In vitro - Schirmer strips were placed for 10 s in contact with microplate wells containing 1 or 2 drops of 0.5% fluorescein. In both experiments, the fluorescein-impregnated Schirmer strips were immediately imaged, and the area and intensity of fluorescein uptake were analyzed with ImageJ software. For the in vitro experiment, images were evaluated by the same examiner (repeatability) or two examiners (reproducibility). Results: Photography-based FCT was easy to perform and showed high repeatability and reproducibility (coefficients of variation <= 2.75%). In vivo, the area and intensity of fluorescein uptake on Schirmer strips were significantly greater at 30 min and 40 min post-fluorescein instillation in the 2 drops vs. 1 drop groups (p <= 0.044). Compared to baseline, the residual fluorescein uptake on Schirmer strips was < 5% at 60 min and 90 min in the 1 drop and 2 drops groups, respectively. Conclusions: Photography-based FCT is a practical and reliable diagnostic tool with various clinical and research applications in veterinary medicine. Instillation of two drops provided greater amount and longer retention on the anesthetized canine ocular surface than a single drop. Fluorescein clearance time of a single drop in dolichocephalic dogs is 60 min.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Reliability of photography-based skin tone annotation using the monk scale and 3D total body photography
    Weir, V. R.
    Gillis, M.
    Halpern, A. C.
    Rotemberg, V.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2024, 144 (08) : S123 - S123
  • [22] BODY, SPACE AND LIGHT IN PHYSICAL THEATER. A PHOTOGRAPHY-BASED EDUCATIONAL RESEARCH PROJECT
    Mendez Suarez, Maria
    Ramirez, Joaquin Roldan
    Viadel, Ricardo Marin
    ARTSEDUCA, 2022, (31): : 287 - 298
  • [23] Photography-based analysis of tourists' temporal-spatial behaviour in the Old Town of Lijiang
    Li, Chunming
    Zhao, Yang
    Sun, Xiaoze
    Su, Xiaodan
    Zheng, Shuanning
    Dong, Rencai
    Shi, Longyu
    INTERNATIONAL JOURNAL OF SUSTAINABLE DEVELOPMENT AND WORLD ECOLOGY, 2011, 18 (06): : 523 - 529
  • [24] Photography-based facade recovery & 3-d modeling: A CAD application in Cultural Heritage
    Styliadis, Athanasios D.
    Sechidis, Lazaros A.
    JOURNAL OF CULTURAL HERITAGE, 2011, 12 (03) : 243 - 252
  • [25] Photography-based real-time long-wave infrared scattering estimation technique
    Luo, Tianqi
    Lin, Di
    Mah, Merlin
    Hashemi, Connor
    Leger, James R.
    Talghader, Joseph J.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2021, 38 (07) : 1041 - 1050
  • [26] Developing a photography-based harvest survey to estimate age and subspecies composition of midcontinent sandhill cranes
    Dinges, Andrew J.
    Vonbank, Jay A.
    Pearse, Aaron T.
    Brandt, David A.
    WILDLIFE SOCIETY BULLETIN, 2024, 48 (01):
  • [27] Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography-based system
    Montalban, Raul
    Alio, Jorge L.
    Javaloy, Jaime
    Pinero, David P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (02): : 211 - 218
  • [28] Performance analysis of design simulator for integral photography-based 3D display system
    Cho, BC
    Kim, ES
    COCKPIT DISPLAYS IX: DISPLAYS FOR DEFENSE APPLICATIONS, 2002, 4712 : 397 - 405
  • [29] "Mending fractured personalities": A photography-based cultural study of recovery from mental distress in Romania
    Milasan, Lucian Hadrian
    TRANSCULTURAL PSYCHIATRY, 2023, 60 (02) : 226 - 243
  • [30] Photography-based photometry: High throughput UV photometric analysis without scientific equipment based on contact printing photography and common imaging devices
    Tzoka, Stefania
    Tarara, Maria
    Giokas, Dimosthenis L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 328