Photography-based method for assessing fluorescein clearance test in dogs

被引:9
|
作者
Oria, Arianne Pontes [1 ]
Reboucas, Miriam Flores [1 ]
Martins Filho, Emanoel [1 ]
Dorea Neto, Francisco de Assis [1 ]
Raposo, Ana Claudia [1 ]
Sebbag, Lionel [2 ]
机构
[1] Univ Fed Bahia, Sch Vet Med & Zootechny, UFBA, Salvador, BA, Brazil
[2] Iowa State Univ, Dept Vet Clin Sci, Coll Vet Med, Ames, IA USA
来源
BMC VETERINARY RESEARCH | 2018年 / 14卷
关键词
Dogs; Fluorescein clearance test; Schirmer tear test; Tear film; TEAR TEST STRIPS; ABSORPTIVE CAPACITIES;
D O I
10.1186/s12917-018-1593-y
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: The fluorescein clearance test (FCT) provides insight into the tear film dynamics. The purpose of this study was to describe an inexpensive and practical method for assessing FCT in dogs, using photography and software analysis, and to assess the retention time of 1 vs. 2 eye drops on the canine ocular surface. Methods: (i) In vivo - Eight healthy German Shepherd dogs were recruited. Following topical anesthesia with 0.5% proxymetacaine, each eye sequentially received (1 week apart) either 1 drop (35 mu L) or 2 drops (70 mu L) of 0.5% fluorescein. A Schirmer strip was inserted in the ventral conjunctival fornix for 10 s at the following times: each 10 min for 100 min, 24 h, 48 h and 72 h. (ii) In vitro - Schirmer strips were placed for 10 s in contact with microplate wells containing 1 or 2 drops of 0.5% fluorescein. In both experiments, the fluorescein-impregnated Schirmer strips were immediately imaged, and the area and intensity of fluorescein uptake were analyzed with ImageJ software. For the in vitro experiment, images were evaluated by the same examiner (repeatability) or two examiners (reproducibility). Results: Photography-based FCT was easy to perform and showed high repeatability and reproducibility (coefficients of variation <= 2.75%). In vivo, the area and intensity of fluorescein uptake on Schirmer strips were significantly greater at 30 min and 40 min post-fluorescein instillation in the 2 drops vs. 1 drop groups (p <= 0.044). Compared to baseline, the residual fluorescein uptake on Schirmer strips was < 5% at 60 min and 90 min in the 1 drop and 2 drops groups, respectively. Conclusions: Photography-based FCT is a practical and reliable diagnostic tool with various clinical and research applications in veterinary medicine. Instillation of two drops provided greater amount and longer retention on the anesthetized canine ocular surface than a single drop. Fluorescein clearance time of a single drop in dolichocephalic dogs is 60 min.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Implementation of design simulator for integral photography-based 3D imaging and display system
    Cho, BC
    Ko, JH
    Kim, ES
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS V, 2002, 4661 : 112 - 119
  • [32] Vision Transformer Model for Predicting the Severity of Diabetic Retinopathy in Fundus Photography-Based Retina Images
    Nazih, Waleed
    Aseeri, Ahmad O.
    Atallah, Osama Youssef
    El-Sappagh, Shaker
    IEEE ACCESS, 2023, 11 : 117546 - 117561
  • [33] A new method for the fluorescein breakup time test
    Korb, DR
    Finnemore, VM
    Herman, JP
    Greiner, LV
    Glonek, T
    Reddy, CV
    Mody, SS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S544 - S544
  • [34] Correlation of tear fluorescein clearance and Schirmer test scores with ocular irritation symptoms
    Afonso, AA
    Monroy, D
    Stern, ME
    Feuer, WJ
    Tseng, SCG
    Pflugfelder, SC
    OPHTHALMOLOGY, 1999, 106 (04) : 803 - 810
  • [35] Impact of retinal photography-based deep learning system on risk stratification for chronic kidney disease progression
    Park, Jung Tak
    Joo, Young Su
    Rim, Tyler Hyungtaek
    Han, Seung Hyeok
    Yoo, Tae-Hyun
    Kang, Shin-Wook
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39
  • [36] Reliability of a human pose tracking algorithm for measuring upper limb joints: comparison with photography-based goniometry
    Fan, Jingyuan
    Gu, Fanbin
    Lv, Lulu
    Zhang, Zhejin
    Zhu, Changbing
    Qi, Jian
    Wang, Honggang
    Liu, Xiaolin
    Yang, Jiantao
    Zhu, Qingtang
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [37] ASSESSMENT OF YOUNG ADULT ALCOHOL CONSUMPTION USING PHOTOGRAPHY-BASED MOBILE APP METHODOLOGY: A FEASIBILITY STUDY
    Fazzino, T. L.
    Martin, C.
    Raheel, A.
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2018, 42 : 254A - 254A
  • [38] Evaluation of Photosensitive Paper Coatings as Detectors for Instrumentation-Free UV Photometric Analysis Based on Photography-Based Photometry
    Choleva, Tatiana G.
    Sfakianaki, Afroditi
    Vlessidis, Athanasios G.
    Giokas, Dimosthenis L.
    CHEMOSENSORS, 2021, 9 (08)
  • [39] A novel non-invasive efficient photography-based technique for length measuring and individual identification of seahorses
    Luzzatto, Diego
    Cussac, Victor
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [40] Reliability of a human pose tracking algorithm for measuring upper limb joints: comparison with photography-based goniometry
    Jingyuan Fan
    Fanbin Gu
    Lulu Lv
    Zhejin Zhang
    Changbing Zhu
    Jian Qi
    Honggang Wang
    Xiaolin Liu
    Jiantao Yang
    Qingtang Zhu
    BMC Musculoskeletal Disorders, 23