Special Zero-Sequence Current Transformers to Determine Fault Connection in Medium Voltage Networks

被引:0
|
作者
Batulko, D., V [1 ]
Nikitin, K., I [1 ]
Ya, Bigun A. [1 ]
机构
[1] Omsk State Tech Univ, Omsk, Russia
关键词
network with isolated neutral; single-phase ground fault; fault connection; current transformers; zero sequence; RESISTANCE GROUNDED SYSTEMS; LOCATION;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The authors have completed an analyzes and propose results of experiments on the use of various types of special transformers of zero sequence current to determine the fault connection in overhead lines with insulated neutral. A device for determining the single-phase earth faults in overhead lines with insulated neutral without installing cable insertion to the first air-line support is offered. An experimental sample of a current transformer of rectangular shape has been developed. The recommendations for use of current transformers of zero sequence current to determine a faulted connection in overhead networks with insulated neutral are formulated.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Zero-sequence admittance used to protect distribution networks with low earth fault currents
    Valroos A.
    Navolochnyi A.A.
    Onisova O.A.
    Solonina I.S.
    Russian Electrical Engineering, 2011, 82 (1) : 32 - 37
  • [32] Analysis and application of zero-sequence voltage of single-phase ground fault asymmetrical system
    Liu, Baowen
    Wang, Chonglin
    Li, Xiaobo
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (28): : 4959 - 4967
  • [33] Fault-Tolerant Strategy for Modular Multilevel Converters With Combined Zero-Sequence Voltage Injection
    Li, Mengwei
    Jiang, Xiangyu
    Chen, Canfeng
    Zhang, Kai
    Xiong, Jian
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (07) : 8101 - 8113
  • [34] Asymmetry parameters for zero sequence component in medium voltage networks
    Marciniak, Lubomir
    PRZEGLAD ELEKTROTECHNICZNY, 2020, 96 (03): : 25 - 28
  • [35] Detecting Eccentricity Fault in Permanent Magnet Synchronous Machines by Means of Zero-Sequence Voltage Component
    Zhan, Haolan
    Wu, Lijian
    Lyu, Zekai
    Du, Yidong
    Duan, Rupeng
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (05) : 6761 - 6774
  • [36] CASE STUDY: MOTOR FAULT RESULTS IN ZERO-SEQUENCE CURRENT IN EXCESS OF GROUNDING RESISTOR RATING
    Proctor, Matt
    Lobitz, Becky
    Ducote, Philip
    2021 IEEE IAS PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE (PCIC), 2021, : 209 - 218
  • [37] ZERO-SEQUENCE FIELD IMPEDANCE OF CABLE NETWORKS AND OPEN-WIRE NETWORKS FOR MAINTAINING NEUTRAL CONNECTION CONDITIONS
    BALZER, G
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1976, 28 (6-7): : 175 - 180
  • [38] High impedance fault detection in distribution networks using randomness of zero-sequence current signal: A detrended fluctuation analysis approach
    Gadanayak, Debadatta Amaresh
    Mishra, Manohar
    Bansal, Ramesh C.
    APPLIED ENERGY, 2024, 368
  • [39] Effect of Load on Zero-Sequence Current in Low Resistance Grounding System with Complex Grounding Fault
    Yu Lei
    Tian Bing
    Lei Jinyong
    Han Bowen
    Wang Gang
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [40] Characteristics of zero-sequence current filtrator for overhead feeder in 10 kV distribution networks
    Qi, Bo
    Chen, Wei-Jiang
    Li, Cheng-Rong
    Zhang, Yuan-Yuan
    Xiao, Meng-Nan
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (11): : 2832 - 2838