Special Zero-Sequence Current Transformers to Determine Fault Connection in Medium Voltage Networks

被引:0
|
作者
Batulko, D., V [1 ]
Nikitin, K., I [1 ]
Ya, Bigun A. [1 ]
机构
[1] Omsk State Tech Univ, Omsk, Russia
关键词
network with isolated neutral; single-phase ground fault; fault connection; current transformers; zero sequence; RESISTANCE GROUNDED SYSTEMS; LOCATION;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The authors have completed an analyzes and propose results of experiments on the use of various types of special transformers of zero sequence current to determine the fault connection in overhead lines with insulated neutral. A device for determining the single-phase earth faults in overhead lines with insulated neutral without installing cable insertion to the first air-line support is offered. An experimental sample of a current transformer of rectangular shape has been developed. The recommendations for use of current transformers of zero sequence current to determine a faulted connection in overhead networks with insulated neutral are formulated.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Zero-Sequence Current Dynamics in Parallel-Connected Voltage Source Converters
    Zhang, Yu
    Jiang, Zhenhua
    2009 IEEE ELECTRIC SHIP TECHNOLOGIES SYMPOSIUM, 2009, : 189 - 196
  • [22] Analysis of influence of unbalanced zero-sequence current on pilot zero-sequence protection and its countermeasures
    Tian, Baojiang
    Zhang, Taisheng
    Chen, Jun
    Zang, Rui
    Liao, Xiaoyu
    Wang, Jingjun
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (19): : 132 - 135
  • [23] Flux-Weakening Control for Variable Flux Reluctance Machine Excited by Zero-Sequence Current Considering Zero-Sequence Resistive Voltage Drop
    Guo, Jiaqiang
    Liu, Xu
    Li, Shanhu
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (01) : 272 - 280
  • [24] Zero-sequence current suppression control for fault current damper based on model predictive control
    Shetgaonkar, Ajay
    Popov, Marjan
    Palensky, Peter
    Lekic, Aleksandra
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
  • [25] Grounding Fault Direction Algorithm Using Zero-sequence Current in Resonant Grounding System
    Jin X.
    Xue Y.
    Peng Z.
    Yang F.
    Xu B.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (09): : 164 - 170
  • [26] Paramater Calculation of Zero-sequence Current Transformer
    Zhao Lianqing
    Sun Na
    PROCEEDINGS OF THE 14TH YOUTH CONFERENCE ON COMMUNICATION, 2009, : 155 - 159
  • [27] DEVELOPMENT OF NEW CONCEPT OPTICAL ZERO-SEQUENCE CURRENT VOLTAGE TRANSDUCERS FOR DISTRIBUTION NETWORK
    AIKAWA, E
    UEDA, A
    WATANABE, M
    TAKAHASHI, H
    IMATAKI, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (01) : 414 - 420
  • [28] Protection scheme based on the fault transient component of zero-sequence voltage under the stator ground fault of generators
    Bi, Da-Qiang
    Wang, Xiang-Heng
    Gui, Lin
    Wang, Wei-Jian
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2003, 23 (11): : 39 - 44
  • [29] Fault-tolerant control for modular multilevel converter based on zero-sequence voltage injection
    Shen, K. (shenkehit@163.com), 1600, Automation of Electric Power Systems Press (38):
  • [30] Zero-Sequence Current and Voltage Control Strategy of Multiple MMCs for Single-Phase Ground Fault Protection in AC-DC Hybrid Distribution Networks
    Zhang, Youwen
    Pei, Xuejun
    Zhou, Peng
    Jin, Haitao
    Shan, Yue
    Wang, Hanyu
    Kang, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (06) : 7727 - 7739