A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes

被引:141
|
作者
Gazzard, G
Friedman, DS
Devereux, JG
Chew, P
Seah, SKL
机构
[1] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[2] Inst Ophthalmol, London, England
[3] Moorfields Eye Hosp, Glaucoma Res Unit, London, England
[4] Singapopre Eye Res Inst, Singapore, Singapore
[5] Johns Hopkins Univ, Wilmer Ophthalmol Inst, Baltimore, MD 21218 USA
[6] Natl Univ Singapore, Singapore 117548, Singapore
关键词
D O I
10.1016/S0161-6420(02)01893-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To prospectively quantify changes in anterior segment morphology after laser iridotomy using gonioscopy and ultrasound biomicroscopy (UBM). Design: Prospective comparative observational case series. Participants: Fifty-five fellow eyes of patients presenting with acute primary angle closure (APAC). Methods: The fellow eyes of patients presenting with APAC were examined with UBM, A-scan ultrasonography, and optical pachymetry at presentation and 2 weeks after sequential argon/neodymium yttrium-aluminum-garnet laser peripheral iridotomy (LPI). UBM images were analyzed using UBM Pro 2000 software. Baseline measurements were made both under standard lighting conditions and in darkness to look for changes in anterior segment findings. Main Outcome Measures: The degree of angle opening was measured using the angle-opening distance (AOD) at 250 and 500 mum from the scleral spur (AOD250 and AOD500, respectively) and angle recess area (ARA). Results: Fifty-five Asian patients were examined; AOD250, AOD500, and ARA all significantly increased after sequential laser iridotomy (P < 0.002). Gonioscopic grading of the angle opening significantly increased in all 4 quadrants (P < 0.001). The Van Herick grade of limbal anterior chamber depth increased (P < 0.001), whereas the number of eyes classified as occludable decreased (73%-33%, P < 0.001). Anterior chamber depth did not change significantly (2.41 mm +/- 0.28 mm vs. 2.42 mm +/- 0.30 mm, P = 0.43) as measured with optical pachymetry. Increased illumination increased the angle-opening measures, but induced a different alteration in peripheral iris morphology. Illumination-induced changes were greater after iridotomy than before laser treatment. Conclusions: In Asian eyes at high risk of developing APAC, sequential LPI produced a significant widening of the anterior chamber angle without deepening the anterior chamber centrally. LPI produces changes in iris morphology that are different from those caused by an increase in illumination, indicating that different mechanisms account for angle opening under these 2 conditions.
引用
收藏
页码:630 / 638
页数:9
相关论文
共 50 条
  • [41] Effect of laser peripheral iridotomy on angle configuration in eyes with angle closure: An evaluation by the anterior segment OCT
    See, JLS
    Chew, PTK
    Nolan, WP
    Zheng, C
    Sunita, R
    Smith, S
    Friedman, D
    Aung, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [42] Histologic correlation with high frequency ultrasound biomicroscopy in eyes with anterior & posterior segment pathology
    Iezzi, R
    Berenstein, D
    McCormick, SA
    Rosen, R
    Stegman, Z
    Liebmann, J
    Walsh, JB
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2787 - 2787
  • [43] Ultrasound biomicroscopy in eyes with anterior chamber flattening after trabeculectomy - Discussion
    Pavlin, CJ
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2002, 37 (01): : 32 - 33
  • [44] ULTRASOUND BIOMICROSCOPY (UBM) OF ANTERIOR SEGMENT STRUCTURES IN VITREOUS SUBSTITUTES-FILLED EYES
    AZZOLINI, C
    PIERRO, L
    CODENOTTI, M
    RESTI, AG
    BRANCATO, R
    VISION RESEARCH, 1995, 35 : 1318 - 1318
  • [45] The use of ultrasound biomicroscopy in the evaluation of anterior segment tumors and simulating conditions
    Guenduez, Kaan
    Hosal, Banu M.
    Zilelioglu, Gueler
    Guenalp, Ilhan
    OPHTHALMOLOGICA, 2007, 221 (05) : 305 - 312
  • [46] Comparing the Effect of Laser Peripheral Iridotomy to Lens Extraction on Anterior Segment Morphology in Narrow Angle Eyes using Anterior Segment Optical Coherence Tomography (ASOCT)
    Gross, Jacob
    Baker, Laura
    Chuang, Alice
    Blieden, Lauren S.
    Bell, Nicholas P.
    Feldman, Robert M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [47] Anterior chamber morphology changes in eyes with narrow angles by Scheimpflug imaging: Pilocarpine versus laser peripheral iridotomy
    Richa Gupta
    Raj Kumar
    Lokesh Chauhan
    International Ophthalmology, 2021, 41 : 2099 - 2108
  • [48] Validation of changes in anterior chamber biometrics in rabbit eyes measured by ultrasound biomicroscopy
    Toris, Carol B.
    Helms, Richard
    Chan, Eric
    Anunike, Ganiru
    Girish, Kshama
    Buzzard, Joshua
    Pattabiraman, Padmanabhan P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [49] Anterior chamber morphology changes in eyes with narrow angles by Scheimpflug imaging: Pilocarpine versus laser peripheral iridotomy
    Gupta, Richa
    Kumar, Raj
    Chauhan, Lokesh
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (06) : 2099 - 2108
  • [50] Morphologic changes in the anterior segment using ultrasound biomicroscopy after cataract surgery and intraocular lens implantation
    Unsal, Erkan
    Eltutar, Kadir
    Muftuoglu, Ilkay K.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (01) : 31 - 38