A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes

被引:141
|
作者
Gazzard, G
Friedman, DS
Devereux, JG
Chew, P
Seah, SKL
机构
[1] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[2] Inst Ophthalmol, London, England
[3] Moorfields Eye Hosp, Glaucoma Res Unit, London, England
[4] Singapopre Eye Res Inst, Singapore, Singapore
[5] Johns Hopkins Univ, Wilmer Ophthalmol Inst, Baltimore, MD 21218 USA
[6] Natl Univ Singapore, Singapore 117548, Singapore
关键词
D O I
10.1016/S0161-6420(02)01893-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To prospectively quantify changes in anterior segment morphology after laser iridotomy using gonioscopy and ultrasound biomicroscopy (UBM). Design: Prospective comparative observational case series. Participants: Fifty-five fellow eyes of patients presenting with acute primary angle closure (APAC). Methods: The fellow eyes of patients presenting with APAC were examined with UBM, A-scan ultrasonography, and optical pachymetry at presentation and 2 weeks after sequential argon/neodymium yttrium-aluminum-garnet laser peripheral iridotomy (LPI). UBM images were analyzed using UBM Pro 2000 software. Baseline measurements were made both under standard lighting conditions and in darkness to look for changes in anterior segment findings. Main Outcome Measures: The degree of angle opening was measured using the angle-opening distance (AOD) at 250 and 500 mum from the scleral spur (AOD250 and AOD500, respectively) and angle recess area (ARA). Results: Fifty-five Asian patients were examined; AOD250, AOD500, and ARA all significantly increased after sequential laser iridotomy (P < 0.002). Gonioscopic grading of the angle opening significantly increased in all 4 quadrants (P < 0.001). The Van Herick grade of limbal anterior chamber depth increased (P < 0.001), whereas the number of eyes classified as occludable decreased (73%-33%, P < 0.001). Anterior chamber depth did not change significantly (2.41 mm +/- 0.28 mm vs. 2.42 mm +/- 0.30 mm, P = 0.43) as measured with optical pachymetry. Increased illumination increased the angle-opening measures, but induced a different alteration in peripheral iris morphology. Illumination-induced changes were greater after iridotomy than before laser treatment. Conclusions: In Asian eyes at high risk of developing APAC, sequential LPI produced a significant widening of the anterior chamber angle without deepening the anterior chamber centrally. LPI produces changes in iris morphology that are different from those caused by an increase in illumination, indicating that different mechanisms account for angle opening under these 2 conditions.
引用
收藏
页码:630 / 638
页数:9
相关论文
共 50 条
  • [31] Ultrasound biomicroscopy in eyes with anterior chamber flattening after trabeculectomy
    Grigera, D
    Moreno, C
    Fava, O
    Girado, SG
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2002, 37 (01): : 27 - 32
  • [32] Changes in anterior segment morphology of iris bombe before and after laser peripheral iridotomy in patients with uveitic secondary glaucoma
    Ikegawa, Wakako
    Suzuki, Takashi
    Mizoue, Shiro
    Ohashi, Yuichi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [33] Agreement between gonioscopy and ultrasound biomicroscopy in the assessment of the anterior chamber angle, before and after laser peripheral iridotomy
    Cortes Alcocer, Claudia
    Mayorquin-Ruiz, Mariana
    Jimenez-Roman, Jesus
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [34] Morphological changes of the anterior segment after laser peripheral iridotomy in primary angle closure
    K Lei
    N Wang
    L Wang
    B Wang
    Eye, 2009, 23 : 345 - 350
  • [35] Longitudinal Changes in Anterior Segment Parameters After Laser Peripheral Iridotomy Assessed by Anterior Segment Optical Coherence Tomography
    Lee, Kyoung Sub
    Sung, Kyung Rim
    Shon, Kilhwan
    Sun, Jae Hong
    Lee, Jong Rak
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3166 - 3170
  • [36] Changes in Anterior Segment Morphology of Iris Bombe before and after Laser Peripheral Iridotomy in Patients with Uveitic Secondary Glaucoma
    Ikegawa, Wakako
    Suzuki, Takashi
    Namiguchi, Koji
    Mizoue, Shiro
    Shiraishi, Atsushi
    Ohashi, Yuichi
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [37] In vivo quantification of anterior segment dimensions in normal and glaucomatous eyes with ultrasound biomicroscopy
    Roters, S
    Welsandt, G
    Mietz, H
    Krieglstein, GK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [38] Morphological changes of the anterior segment after laser peripheral iridotomy in primary angle closure
    Lei, K.
    Wang, N.
    Wang, L.
    Wang, B.
    EYE, 2009, 23 (02) : 345 - 350
  • [39] COMPARATIVE EVALUATION OF ANTERIOR SEGMENT OPTICAL COHERENCE TOMOGRAPHY, ULTRASOUND BIOMICROSCOPY, AND INTRAOCULAR PRESSURE CHANGES AFTER PANRETINAL PHOTOCOAGULATION BY PASCAL AND CONVENTIONAL LASER
    Lata, Suman
    Venkatesh, Pradeep
    Temkar, Shreyas
    Selvan, Harathy
    Gupta, Viney
    Dada, Tanuj
    Upadhyay, Ashish D.
    Sihota, Ramanjit
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (03): : 537 - 545
  • [40] Ultrasound biomicroscopy of the anterior segment after congenital cataract surgery
    Nishijima, K
    Takahashi, K
    Yamakawa, R
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (04) : 483 - 489