A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes

被引:141
|
作者
Gazzard, G
Friedman, DS
Devereux, JG
Chew, P
Seah, SKL
机构
[1] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[2] Inst Ophthalmol, London, England
[3] Moorfields Eye Hosp, Glaucoma Res Unit, London, England
[4] Singapopre Eye Res Inst, Singapore, Singapore
[5] Johns Hopkins Univ, Wilmer Ophthalmol Inst, Baltimore, MD 21218 USA
[6] Natl Univ Singapore, Singapore 117548, Singapore
关键词
D O I
10.1016/S0161-6420(02)01893-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To prospectively quantify changes in anterior segment morphology after laser iridotomy using gonioscopy and ultrasound biomicroscopy (UBM). Design: Prospective comparative observational case series. Participants: Fifty-five fellow eyes of patients presenting with acute primary angle closure (APAC). Methods: The fellow eyes of patients presenting with APAC were examined with UBM, A-scan ultrasonography, and optical pachymetry at presentation and 2 weeks after sequential argon/neodymium yttrium-aluminum-garnet laser peripheral iridotomy (LPI). UBM images were analyzed using UBM Pro 2000 software. Baseline measurements were made both under standard lighting conditions and in darkness to look for changes in anterior segment findings. Main Outcome Measures: The degree of angle opening was measured using the angle-opening distance (AOD) at 250 and 500 mum from the scleral spur (AOD250 and AOD500, respectively) and angle recess area (ARA). Results: Fifty-five Asian patients were examined; AOD250, AOD500, and ARA all significantly increased after sequential laser iridotomy (P < 0.002). Gonioscopic grading of the angle opening significantly increased in all 4 quadrants (P < 0.001). The Van Herick grade of limbal anterior chamber depth increased (P < 0.001), whereas the number of eyes classified as occludable decreased (73%-33%, P < 0.001). Anterior chamber depth did not change significantly (2.41 mm +/- 0.28 mm vs. 2.42 mm +/- 0.30 mm, P = 0.43) as measured with optical pachymetry. Increased illumination increased the angle-opening measures, but induced a different alteration in peripheral iris morphology. Illumination-induced changes were greater after iridotomy than before laser treatment. Conclusions: In Asian eyes at high risk of developing APAC, sequential LPI produced a significant widening of the anterior chamber angle without deepening the anterior chamber centrally. LPI produces changes in iris morphology that are different from those caused by an increase in illumination, indicating that different mechanisms account for angle opening under these 2 conditions.
引用
收藏
页码:630 / 638
页数:9
相关论文
共 50 条
  • [21] Evaluation of the Changes in Anterior Segment Morphology After Laser Peripheral Iridotomy Through One-Year Follow-Up
    Yigit, Ulviye
    Onur, Umut
    Acet, Yakup
    Agachan, Ahmet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (01): : 6 - 10
  • [22] Dynamic Changes in Anterior Segment Morphology during the Valsalva Maneuver Assessed with Ultrasound Biomicroscopy
    Wang, Bing-Song
    Xiao, Lin
    Liu, Jing
    Dong, Ning
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (11) : 7286 - 7289
  • [23] Evaluation of Anterior Segment Morphology after Laser Peripheral Iridotomy: Five Year Follow-Up
    Huang, Susan
    Park, Jennifer
    Reddy, Swathi
    Shrivastava, Anurag
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [24] Evaluation of anterior segment foreign bodies with ultrasound biomicroscopy
    de Moura, Marilia Freitas
    Hayashi, Ilka
    Rocha, Daniel Martins
    Allemann, Norma
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (02) : 122 - 125
  • [25] Evaluation of Changes in Anterior Segment Configuration by Ultrasound Biomicroscopy after Phacoemulsification and Foldable Intraocular Lens Implantation
    Salcan, Ilhami
    Aykan, Umit
    Yilmaz, Burhan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (04): : 200 - 206
  • [26] Changes in Anterior Segment Parameters After Laser Peripheral Iridotomy in Caucasian Eyes With Different Primary Angle Closure Mechanisms
    Tun, Tin A.
    Sawicki, Andrzej
    Wilkos-Kuc, Agnieszka
    Aung, Tin
    Zarnowski, Tomasz
    JOURNAL OF GLAUCOMA, 2023, 32 (10) : 820 - 825
  • [27] Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure
    Mansouri, K.
    Sommerhalder, J.
    Shaarawy, T.
    EYE, 2010, 24 (02) : 233 - 239
  • [28] Circumferential Assessment of Changes in Anterior Segment Characteristics and Baseline Predictors of Angle Widening After Laser Iridotomy in Caucasian Eyes
    Tun, Tin A.
    Sawicki, Andrzej
    Wilkos-Kuc, Agnieszka
    Aung, Tin
    Zarnowski, Tomasz
    JOURNAL OF GLAUCOMA, 2021, 30 (09) : 839 - 845
  • [29] Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure
    K Mansouri
    J Sommerhalder
    T Shaarawy
    Eye, 2010, 24 : 233 - 239
  • [30] Quantitative evaluation of anterior chamber changes after iridotomy using Pentacam anterior segment analyzer
    Lopez-Caballero, Cristina
    Puerto-Hernandez, Beatriz
    Munoz-Negrete, Francisco J.
    Rebolleda, Gema
    Contreras, Ines
    Cabarga, Carmen
    Corral, Angeles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (02) : 327 - 332