Factors Affecting Microbial Contamination on the Back Surface of Worn Soft Contact Lenses

被引:5
|
作者
Tan, Jacqueline [1 ]
Siddireddy, Jaya Sowjanya [1 ]
Wong, Katherine [1 ]
Shen, Qing [1 ]
Vijay, Ajay Kumar [1 ]
Stapleton, Fiona [1 ]
机构
[1] Univ New South Wales, Sch Optometry & Vis Sci, Fac Med & Hlth, Sydney, NSW, Australia
关键词
PSEUDOMONAS-AERUGINOSA; RISK-FACTORS; IDENTIFICATION; KERATITIS; ADHESION; EVENTS; WEAR;
D O I
10.1097/OPX.0000000000001693
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE The results of this study demonstrate that Smart Touch Technology packaging, which is designed to reduce and simplify contact lens handling before insertion, is effective in reducing the frequency of bacterial contamination of the back surface of contact lenses after short-term wear. PURPOSE The purpose of this study was to investigate the effect of lens packaging type, chelating agent, and finger contamination on microbial contamination on the back surface of worn soft contact lenses. METHODS Twenty-five subjects completed each contralateral lens wear comparison in this randomized study: Smart Touch Technology versus conventional blister packaging for (1) silicone hydrogel lenses with ethylenediaminetetraacetic acid (EDTA) and (2) hydrogel lenses without EDTA in the packaging, and (3) silicone hydrogel lenses without EDTA versus hydrogel lenses with EDTA both in Smart Touch Technology packaging. Participants washed hands, underwent finger swabs, and inserted the lenses. After 45 minutes, lenses were removed aseptically and the posterior lens surfaces cultured. RESULTS Thirty-eight subjects (average age, 30.9 +/- 12.5 years) participated in this study. Overall, the level of back surface contamination was low for both lens materials, ranging from 0 to 43 colony-forming unit (CFU)/lens for the silicone hydrogel and 0 to 17 CFU/lens for the hydrogel lenses. The proportion of lenses with zero back surface contamination ranged from 16 to 64% for silicone hydrogel lenses and 28 to 64% for hydrogel lenses. Contact lenses from conventional packaging containing EDTA had 3.38 times increased risk (95% confidence interval [CI], 1.02 to 11.11; P = .05) of contamination being present compared with lenses from Smart Touch packaging with EDTA. Contact lenses from conventional packaging without EDTA had 3.4 times increased risk (95% CI, 1.02 to 11.36; P = .05) of contamination being present compared with Smart Touch packaging without EDTA, and silicone hydrogel lenses had a 6.28 times increased risk (95% CI, 1.65 to 23.81; P = .007) of contamination being present compared with hydrogels. The median (interquartile range) number of bacteria isolated from fingers used to perform lens insertion after handwashing but before lens insertion was not significantly different between the silicone hydrogel and hydrogel lenses (63.7 [204.2] vs. 59 [84.5], P = .09). Finger contamination was not significantly associated with lens contamination in the presence or absence of EDTA. CONCLUSIONS Smart Touch Technology packaging was effective in reducing the proportion of contaminated lenses. Although silicone hydrogel lenses were more likely to be contaminated, the presence of EDTA ameliorated this effect. Finger contamination was not associated with lens contamination.
引用
收藏
页码:512 / 517
页数:6
相关论文
共 50 条
  • [21] Atomic Force Microscopy and Coefficient of Friction Analysis of Unworn and Worn Soft Contact Lenses
    Schafer, Jeffery
    Steffen, Robert
    Wygladacz, Katarzyna A.
    Lusignan, Charles
    Hook, Daniel
    Simoncelli, Kristin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [22] CARBOHYDRATE DEPOSITS ON THE SURFACES OF WORN EXTENDED-WEAR SOFT CONTACT-LENSES
    KLOTZ, SA
    MISRA, RP
    BUTRUS, SI
    ARCHIVES OF OPHTHALMOLOGY, 1987, 105 (07) : 974 - 977
  • [23] INSPECTION OF BACK SURFACE ASPHERIC CONTACT-LENSES
    DEFAZIO, AJ
    LOWTHER, GE
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1979, 56 (08): : 471 - 479
  • [24] MICROBIAL-CONTAMINATION OF CASES USED FOR STORING CONTACT-LENSES
    CLARK, BJ
    HARKINS, LS
    MUNRO, FA
    DEVONSHIRE, P
    JOURNAL OF INFECTION, 1994, 28 (03) : 293 - 304
  • [25] Surface AFM Microscopy of Unworn and Worn Samples of Silicone Hydrogel Contact Lenses
    Gonzalez-Meijome, J. M.
    Lopez-Alemany, A.
    Almeida, J. B.
    Parafita, M. A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (01) : 75 - 82
  • [26] CHANGES IN BACK RADIUS OF SOFT CONTACT-LENSES WHEN FLEXED
    WEISSMAN, BA
    ZISMAN, F
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1979, 56 (10): : 613 - 617
  • [27] Analysis of P. aeruginosa disinfectant sensitivity and microbial adhesions to worn cosmetic contact lenses
    Shen, Elizabeth P.
    Chu, Hsiao-Sang
    Hsieh, Yi-Ting
    Chen, Wei -Li
    Chang, Shan-Chwen
    Hu, Fung-Rong
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (04): : 338 - 344
  • [28] MICROBIAL-CONTAMINATION OF HYDROPHILIC CONTACT-LENSES IN PATIENT USE SITUATIONS
    MOWREYMCKEE, MF
    MONNATH, K
    SAMPSON, HJ
    SMITH, CM
    DAVIES, GA
    MANDT, L
    PROSKIN, HM
    HART, DE
    REINDEL, W
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 142 - PMSE
  • [29] Microbial contamination of therapeutic contact lenses after photorefractive keratectomy: a prospective analysis
    Soleimani, Mohammad
    Najafabadi, Omid Behjati
    Atighehchian, Mehrnaz
    Razavi, Alireza
    Abedinifar, Zohreh
    Tabatabaei, Seyed Ali
    Asadigandomani, Hassan
    JOURNAL OF OPHTHALMIC INFLAMMATION AND INFECTION, 2025, 15 (01):
  • [30] Microbial Contamination of Contact Lenses, Lens Care Solutions, and Their Accessories: A Literature Review
    Szczotka-Flynn, Loretta B.
    Pearlman, Eric
    Ghannoum, Mahmoud
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2010, 36 (02): : 116 - 129