Surface AFM Microscopy of Unworn and Worn Samples of Silicone Hydrogel Contact Lenses

被引:31
|
作者
Gonzalez-Meijome, J. M. [1 ]
Lopez-Alemany, A. [2 ]
Almeida, J. B. [2 ]
Parafita, M. A. [3 ]
机构
[1] Univ Minho, Sch Sci, Dept Phys Optometry, Braga, Portugal
[2] Univ Valencia, Dept Opt, Valencia, Spain
[3] Univ Santiago de Compostela, Sch Opt & Optometry, Dept Surg Ophthalmol, Santiago De Compostela, Spain
关键词
atomic force microscopy; contact lens; degradation; surface characterization; wear; ATOMIC-FORCE MICROSCOPY; PSEUDOMONAS-AERUGINOSA; CONVENTIONAL HYDROGEL; ADHESION; ATTACHMENT; ETAFILCON; OVERWEAR; WEAR;
D O I
10.1002/jbm.b.31153
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. To evaluate the qualitative and quantitative topographic changes in the surface of worn contact lenses (CLs) of different materials using atomic force microscopy (AFM). Methods. The topography of five different CL materials was evaluated with AFM over a surface of 25 mu m(2) according to previously published experimental setup. Average roughness (R-a) and root mean square (Rms) values were obtained for unworn and worn samples. Results. The R-a, value increased for balafilcon A (11.62-13.68 nm for unworn and worn samples, respectively), lotrafilcon A (3.67-15.01 nm for unworn and worn samples, respectively), lotrafilcon B (4.08-8.42 nm for unworn and worn samples, respectively), galyfilcon A (2.81-14.6 nm for unworn and worn samples, respectively), and comfilcon A (2.87-4.63 mu for unworn and worn samples, respectively). Differences were statistically significant for all lenses except Rms and R-a for comfilcon A, and R-a parameter for balafilcon A (p > 0.05). The least relative increase was observed for some balarilcon A samples and for some of these samples the roughness decreased after the lenses had been worn. Conclusion. The changes in surface roughness between unworn and worn lenses are different for different silicone-hydrogel materials. Overall all CLs increased the degree of surface roughness after being worn, even for very short periods of time. However, for samples of balafilcon A, roughness increases at a lower extent or even can decrease as compared to unworn samples of the same material due to filling of the macropores. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 88B: 75-82, 2009
引用
收藏
页码:75 / 82
页数:8
相关论文
共 50 条
  • [1] Bacterial Adhesion to Unworn and Worn Silicone Hydrogel Lenses
    Vijay, Ajay Kumar
    Zhu, Hua
    Ozkan, Jerome
    Wu, Duojia
    Masoudi, Simin
    Bandara, Rani
    Borazjani, Roya N.
    Willcox, Mark D. P.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (08) : 1095 - 1106
  • [2] Dynamic In Vitro Dehydration Patterns of Unworn and Worn Silicone Hydrogel Contact Lenses
    Gonzalez-Meijome, J. M.
    Lopez-Alemany, A.
    Almeida, J. B.
    Parafita, M. A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 90B (01) : 250 - 258
  • [3] Comparing the static and kinetic friction of unworn and worn silicone hydrogel contact lenses
    Hook, Daniel
    Taft, Sandra
    Steffen, Robert
    Merchea, Mohinder M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [4] Bacterial adhesion to worn silicone hydrogel contact lenses
    Santos, Livia
    Rodrigues, Diana
    Lira, Madalena
    Real Oliveira, M. Elisabete C. D.
    Oliveira, Rosario
    Yebra-Pimentel Vilar, Eva
    Azeredo, Joana
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (07) : 520 - 525
  • [5] Atomic Force Microscopy and Coefficient of Friction Analysis of Unworn and Worn Soft Contact Lenses
    Schafer, Jeffery
    Steffen, Robert
    Wygladacz, Katarzyna A.
    Lusignan, Charles
    Hook, Daniel
    Simoncelli, Kristin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [6] Surface characterization of worn hydrogel contact lenses.
    StJohn, HAW
    Kingshott, P
    Griesser, HJ
    Morris, C
    Bolis, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 49 - PMSE
  • [7] Silicone hydrogel contact lenses and the ocular surface
    Stapleton, F
    Stretton, S
    Papas, E
    Skotnitsky, C
    Sweeney, DF
    OCULAR SURFACE, 2006, 4 (01): : 24 - 43
  • [8] Study of silicone hydrogel contact lenses' surface reflection characteristics using confocal microscopy
    Sulinski, Tomasz
    Nowak, Natalia
    Szymanski, Jedrzej
    Pniewski, Jacek
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2023, 34 (17) : 2400 - 2410
  • [9] Adherence of Acanthamoeba to unworn disposable and nondisposable hydrogel contact lenses
    RodriguezAres, T
    Lema, I
    Penalver, D
    deRojas, V
    Capeans, C
    SanchezSalorio, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1338 - 1338
  • [10] Coefficient of Friction Analysis of Unworn and Worn Daily Disposable Contact Lenses
    Schafer, Jeffery
    Hook, Daniel
    Lusignan, Charles
    Steffen, Robert B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)