Factors Affecting Microbial Contamination on the Back Surface of Worn Soft Contact Lenses

被引:5
|
作者
Tan, Jacqueline [1 ]
Siddireddy, Jaya Sowjanya [1 ]
Wong, Katherine [1 ]
Shen, Qing [1 ]
Vijay, Ajay Kumar [1 ]
Stapleton, Fiona [1 ]
机构
[1] Univ New South Wales, Sch Optometry & Vis Sci, Fac Med & Hlth, Sydney, NSW, Australia
关键词
PSEUDOMONAS-AERUGINOSA; RISK-FACTORS; IDENTIFICATION; KERATITIS; ADHESION; EVENTS; WEAR;
D O I
10.1097/OPX.0000000000001693
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE The results of this study demonstrate that Smart Touch Technology packaging, which is designed to reduce and simplify contact lens handling before insertion, is effective in reducing the frequency of bacterial contamination of the back surface of contact lenses after short-term wear. PURPOSE The purpose of this study was to investigate the effect of lens packaging type, chelating agent, and finger contamination on microbial contamination on the back surface of worn soft contact lenses. METHODS Twenty-five subjects completed each contralateral lens wear comparison in this randomized study: Smart Touch Technology versus conventional blister packaging for (1) silicone hydrogel lenses with ethylenediaminetetraacetic acid (EDTA) and (2) hydrogel lenses without EDTA in the packaging, and (3) silicone hydrogel lenses without EDTA versus hydrogel lenses with EDTA both in Smart Touch Technology packaging. Participants washed hands, underwent finger swabs, and inserted the lenses. After 45 minutes, lenses were removed aseptically and the posterior lens surfaces cultured. RESULTS Thirty-eight subjects (average age, 30.9 +/- 12.5 years) participated in this study. Overall, the level of back surface contamination was low for both lens materials, ranging from 0 to 43 colony-forming unit (CFU)/lens for the silicone hydrogel and 0 to 17 CFU/lens for the hydrogel lenses. The proportion of lenses with zero back surface contamination ranged from 16 to 64% for silicone hydrogel lenses and 28 to 64% for hydrogel lenses. Contact lenses from conventional packaging containing EDTA had 3.38 times increased risk (95% confidence interval [CI], 1.02 to 11.11; P = .05) of contamination being present compared with lenses from Smart Touch packaging with EDTA. Contact lenses from conventional packaging without EDTA had 3.4 times increased risk (95% CI, 1.02 to 11.36; P = .05) of contamination being present compared with Smart Touch packaging without EDTA, and silicone hydrogel lenses had a 6.28 times increased risk (95% CI, 1.65 to 23.81; P = .007) of contamination being present compared with hydrogels. The median (interquartile range) number of bacteria isolated from fingers used to perform lens insertion after handwashing but before lens insertion was not significantly different between the silicone hydrogel and hydrogel lenses (63.7 [204.2] vs. 59 [84.5], P = .09). Finger contamination was not significantly associated with lens contamination in the presence or absence of EDTA. CONCLUSIONS Smart Touch Technology packaging was effective in reducing the proportion of contaminated lenses. Although silicone hydrogel lenses were more likely to be contaminated, the presence of EDTA ameliorated this effect. Finger contamination was not associated with lens contamination.
引用
收藏
页码:512 / 517
页数:6
相关论文
共 50 条
  • [41] Automated surface sampling of lipids from worn contact lenses coupled with tandem mass spectrometry
    Brown, Simon H. J.
    Huxtable, Liam H.
    Willcox, Mark D. P.
    Blanksby, Stephen J.
    Mitchell, Todd W.
    ANALYST, 2013, 138 (05) : 1316 - 1320
  • [42] XPS and surface-MALDI-MS characterisation of worn HEMA-based contact lenses
    McArthur, SL
    McLean, KM
    St John, HAW
    Griesser, HJ
    BIOMATERIALS, 2001, 22 (24) : 3295 - 3304
  • [43] Sliding Friction Coefficient of Soft Surface-Gel Coatings for Soft Contact Lenses
    Radke, Clayton J.
    Bregante, Daniel
    Chong, Halbert
    Dursch, Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [44] CONTACT-LENSES AND OTHER RISK-FACTORS IN MICROBIAL KERATITIS
    DART, JKG
    STAPLETON, F
    MINASSIAN, D
    LANCET, 1991, 338 (8768): : 650 - 653
  • [45] Efficiency and Related Factors of Multifocal Soft Contact Lenses in Controlling Myopia
    Peng, Tianli
    Jiang, Jun
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2023, 49 (12): : 535 - 541
  • [46] Surface chemical structure for soft contact lenses as a function of polymer processing
    Grobe, GL
    Valint, PL
    Ammon, DM
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1996, 32 (01): : 45 - 54
  • [47] Surface chemical structure for soft contact lenses as a function of polymer processing
    Bausch and Lomb, Contact Lens Division, 1400 North Goodman Street, Rochester, NY 14692, United States
    J. BIOMED. MATER. RES., 1 (45-54):
  • [48] SCANNING ELECTRON-MICROSCOPY, X-RAY-MICROANALYSIS AND IMMUNOHISTOCHEMISTRY ON WORN SOFT CONTACT-LENSES
    VERSURA, P
    MALTARELLO, MC
    ROOMANS, GM
    CARAMAZZA, R
    LASCHI, R
    SCANNING MICROSCOPY, 1988, 2 (01) : 397 - 410
  • [49] Factors affecting microbial contamination rate of cord blood collected for transplantation
    Clark, Pamela
    Trickett, Annnette
    Stark, Damien
    Vowels, Marcus
    TRANSFUSION, 2012, 52 (08) : 1770 - 1777