Periodontitis detection efficacy of film and digital images

被引:22
|
作者
Nair, MK [1 ]
Ludlow, JB
Tyndall, DA
Platin, E
Denton, G
机构
[1] Univ Pittsburgh, Sch Dent Med, Dept Oral & Maxillofacial Radiol, Pittsburgh, PA 15261 USA
[2] Univ N Carolina, Sch Dent, Dept Diagnost Sci, Chapel Hill, NC USA
[3] Univ N Carolina, Sch Dent, Dept Oral Radiol, Chapel Hill, NC USA
关键词
D O I
10.1016/S1079-2104(98)90299-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to evaluate the accuracy of alveolar crestal bone detection in a comparison of unenhanced and enhanced Sidexis (Siemens Medical Systems, inc., Bensheim, Germany) digital images with Ektaspeed Plus (Eastman Kodak, Rochester, N.Y.) films by means of receiver operating characteristic analysis. Study Design. More than 100 proximal and furcal areas in the anterior and posterior areas of the mandible and maxilla of each of three tissue-equivalent human skull phantoms were imaged with film, direct digital images, and contrast- and brightness-enhanced digital images. Alveolar crest status was assessed by a consensus panel of three experts who used the Delphi method and evaluated information from ail of the imaging modalities concurrently. Five observers assessed all images for the presence or absence of crestal bone loss using a five-point confidence scale. Receiver operating characteristic curves were generated, and calculated areas (A(Z)) were analyzed by means of analysis of variance. Results. The expert panel determined that of 106 crestal areas, 48 were disease free and 58 exhibited bone loss greater than 2 mm apical to the cemento-enamel junction. Analysis of variance of observer A, scores showed significant differences among readers (p < 0.001) and among readings (p = 0.027), but not among modalities (p = 0.435). Mean A(Z) values for the different modalities were as follows: Sidexis, 0.70; enhanced Sidexis, 0.71; Ektaspeed Plus films, 0.735. Conclusion, The Sidexis digital imaging system was not significantly different from Ektaspeed Plus film for crestal bone evaluation in this in vitro study.
引用
收藏
页码:608 / 612
页数:5
相关论文
共 50 条
  • [1] On the detection of pornographic digital images
    Schettini, R
    Brambilla, C
    Cusano, C
    Ciocca, G
    VISUAL COMMUNICATIONS AND IMAGE PROCESSING 2003, PTS 1-3, 2003, 5150 : 2105 - 2113
  • [2] Diagnostic accuracy of intraoral film and direct digital images for detection of simulated recurrent decay
    Nair, MK
    Ludlow, JB
    May, KN
    Nair, UP
    Johnson, MP
    Close, JM
    OPERATIVE DENTISTRY, 2001, 26 (03) : 223 - 230
  • [3] Periodontal probing on digital images compared to clinical measurements in periodontitis patients
    Chung, Hye-Min
    Park, Jin-Young
    Ko, Kyung-A
    Kim, Chang-Sung
    Choi, Seong-Ho
    Lee, Jung-Seok
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] Periodontal probing on digital images compared to clinical measurements in periodontitis patients
    Hye-Min Chung
    Jin-Young Park
    Kyung-A. Ko
    Chang-Sung Kim
    Seong-Ho Choi
    Jung-Seok Lee
    Scientific Reports, 12
  • [5] A comparative evaluation of the diagnostic efficacy of film and digital sensors for detection of simulated periapical lesions
    Wallace, JA
    Nair, MK
    Colaco, MF
    Kapa, SF
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 92 (01): : 93 - 97
  • [6] Automatic Detection of Periodontitis Using Intra-Oral Images
    Balaei, Asghar Tabatabaei
    de Chazal, Philip
    Eberhard, Joerg
    Domnisch, Henrik
    Spahr, Axel
    Ruiz, Kate
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 3906 - 3909
  • [7] Presentation matching of digital radiographic images to analog screen film images
    Kump, KS
    Schubert, SF
    RADIOLOGY, 1999, 213P : 320 - 321
  • [8] On Detection of Median Filtering in Digital Images
    Kirchner, Matthias
    Fridrich, Jessica
    MEDIA FORENSICS AND SECURITY II, 2010, 7541
  • [9] Automatic children detection in digital images
    Weda, Hans
    Barbieri, Mauro
    2007 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO, VOLS 1-5, 2007, : 1687 - 1690
  • [10] The Blind Detection Technology of Digital Images
    Tian Xiao-zheng
    Chen Ke-wei
    Gao Hai-ying
    INTERNATIONAL CONFERENCE OF CHINA COMMUNICATION (ICCC2010), 2010, : 398 - +